Cargando…

A Novel Approach to Relative Radiometric Calibration on Spatial and Temporal Variations for FORMOSAT-5 RSI Imagery

Radiometric calibration for imaging sensors is a crucial procedure to ensure imagery quality. One of the challenges in relative radiometric calibration is to correct detector-level artifacts due to the fluctuation in discrepant responses (spatial) and electronic instability (temporal). In this paper...

Descripción completa

Detalles Bibliográficos
Autores principales: Lin, Tang-Huang, Hsiao, Min-Chung, Chan, Hai-Po, Tsai, Fuan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6068953/
https://www.ncbi.nlm.nih.gov/pubmed/29933641
http://dx.doi.org/10.3390/s18071996
_version_ 1783343385484984320
author Lin, Tang-Huang
Hsiao, Min-Chung
Chan, Hai-Po
Tsai, Fuan
author_facet Lin, Tang-Huang
Hsiao, Min-Chung
Chan, Hai-Po
Tsai, Fuan
author_sort Lin, Tang-Huang
collection PubMed
description Radiometric calibration for imaging sensors is a crucial procedure to ensure imagery quality. One of the challenges in relative radiometric calibration is to correct detector-level artifacts due to the fluctuation in discrepant responses (spatial) and electronic instability (temporal). In this paper, the integration of the empirical mode decomposition (EMD) with Hilbert–Huang transform (HHT) in relative radiometric calibration was explored for a new sensor, FS-5 RSI (remote sensing instrument onboard the FORMOSAT-5 satellite). The key intrinsic mode functions (IMFs) analyzed by HHT were examined with the pre-flight datasets of the FS-5 RSI in temporal and spatial variations. The results show that the EMD–HHT method can stabilize and improve the radiometric quality of the FS-5 imagery as well as boost its application ability to a new level. It is noticed that the IMFs of the spatial variation would be disturbed by the instability of the temporal variation. The relative response discrepancies among detector chips can be well calibrated after considering the temporal effect. Taking a test imagery dataset of gain setting G2 as an example, the standard deviation (STD) of the discrepancy in the digital number after calibration was dramatically scaled down compared to the original ones (e.g., PAN: 66.31 to 1.85; B1: 54.19 to 1.90; B2: 36.50 to 1.49; B3: 32.43 to 1.56; B4: 37.67 to 1.20). The good performance of pre-flight imagery indicates that the EMD–HHT approach could be highly practical to the on-orbit relative radiometric calibration of the FS-5 RSI sensor and is applicable to other optical sensors. To our knowledge, the proposed EMD–HHT approach is used for the first time to explore relative radiometric calibration for optical sensors.
format Online
Article
Text
id pubmed-6068953
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-60689532018-08-07 A Novel Approach to Relative Radiometric Calibration on Spatial and Temporal Variations for FORMOSAT-5 RSI Imagery Lin, Tang-Huang Hsiao, Min-Chung Chan, Hai-Po Tsai, Fuan Sensors (Basel) Article Radiometric calibration for imaging sensors is a crucial procedure to ensure imagery quality. One of the challenges in relative radiometric calibration is to correct detector-level artifacts due to the fluctuation in discrepant responses (spatial) and electronic instability (temporal). In this paper, the integration of the empirical mode decomposition (EMD) with Hilbert–Huang transform (HHT) in relative radiometric calibration was explored for a new sensor, FS-5 RSI (remote sensing instrument onboard the FORMOSAT-5 satellite). The key intrinsic mode functions (IMFs) analyzed by HHT were examined with the pre-flight datasets of the FS-5 RSI in temporal and spatial variations. The results show that the EMD–HHT method can stabilize and improve the radiometric quality of the FS-5 imagery as well as boost its application ability to a new level. It is noticed that the IMFs of the spatial variation would be disturbed by the instability of the temporal variation. The relative response discrepancies among detector chips can be well calibrated after considering the temporal effect. Taking a test imagery dataset of gain setting G2 as an example, the standard deviation (STD) of the discrepancy in the digital number after calibration was dramatically scaled down compared to the original ones (e.g., PAN: 66.31 to 1.85; B1: 54.19 to 1.90; B2: 36.50 to 1.49; B3: 32.43 to 1.56; B4: 37.67 to 1.20). The good performance of pre-flight imagery indicates that the EMD–HHT approach could be highly practical to the on-orbit relative radiometric calibration of the FS-5 RSI sensor and is applicable to other optical sensors. To our knowledge, the proposed EMD–HHT approach is used for the first time to explore relative radiometric calibration for optical sensors. MDPI 2018-06-21 /pmc/articles/PMC6068953/ /pubmed/29933641 http://dx.doi.org/10.3390/s18071996 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Lin, Tang-Huang
Hsiao, Min-Chung
Chan, Hai-Po
Tsai, Fuan
A Novel Approach to Relative Radiometric Calibration on Spatial and Temporal Variations for FORMOSAT-5 RSI Imagery
title A Novel Approach to Relative Radiometric Calibration on Spatial and Temporal Variations for FORMOSAT-5 RSI Imagery
title_full A Novel Approach to Relative Radiometric Calibration on Spatial and Temporal Variations for FORMOSAT-5 RSI Imagery
title_fullStr A Novel Approach to Relative Radiometric Calibration on Spatial and Temporal Variations for FORMOSAT-5 RSI Imagery
title_full_unstemmed A Novel Approach to Relative Radiometric Calibration on Spatial and Temporal Variations for FORMOSAT-5 RSI Imagery
title_short A Novel Approach to Relative Radiometric Calibration on Spatial and Temporal Variations for FORMOSAT-5 RSI Imagery
title_sort novel approach to relative radiometric calibration on spatial and temporal variations for formosat-5 rsi imagery
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6068953/
https://www.ncbi.nlm.nih.gov/pubmed/29933641
http://dx.doi.org/10.3390/s18071996
work_keys_str_mv AT lintanghuang anovelapproachtorelativeradiometriccalibrationonspatialandtemporalvariationsforformosat5rsiimagery
AT hsiaominchung anovelapproachtorelativeradiometriccalibrationonspatialandtemporalvariationsforformosat5rsiimagery
AT chanhaipo anovelapproachtorelativeradiometriccalibrationonspatialandtemporalvariationsforformosat5rsiimagery
AT tsaifuan anovelapproachtorelativeradiometriccalibrationonspatialandtemporalvariationsforformosat5rsiimagery
AT lintanghuang novelapproachtorelativeradiometriccalibrationonspatialandtemporalvariationsforformosat5rsiimagery
AT hsiaominchung novelapproachtorelativeradiometriccalibrationonspatialandtemporalvariationsforformosat5rsiimagery
AT chanhaipo novelapproachtorelativeradiometriccalibrationonspatialandtemporalvariationsforformosat5rsiimagery
AT tsaifuan novelapproachtorelativeradiometriccalibrationonspatialandtemporalvariationsforformosat5rsiimagery