Cargando…

Loosening Monitoring of the Threaded Pipe Connection Using Time Reversal Technique and Piezoceramic Transducers

Threaded pipe connections are commonly used in the oil and gas industry in particular to connect casting strings, drill pipe strings, production and transportation risers, and pipelines. As the most critical components in the entire chain, maintaining a sealed and secure connection while being subje...

Descripción completa

Detalles Bibliográficos
Autores principales: Liang, Yabin, Feng, Qian, Li, Dongsheng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6068957/
https://www.ncbi.nlm.nih.gov/pubmed/30011914
http://dx.doi.org/10.3390/s18072280
_version_ 1783343386414022656
author Liang, Yabin
Feng, Qian
Li, Dongsheng
author_facet Liang, Yabin
Feng, Qian
Li, Dongsheng
author_sort Liang, Yabin
collection PubMed
description Threaded pipe connections are commonly used in the oil and gas industry in particular to connect casting strings, drill pipe strings, production and transportation risers, and pipelines. As the most critical components in the entire chain, maintaining a sealed and secure connection while being subjected to environmental loads and pollution is very important and necessary to reduce potential leakage risk and guarantee the safety of the entire chain. In this paper, an effective approach using time reversal technique and lead zirconate titanate (PZT) transducer was developed to monitor the looseness of the threaded pipe connection. Two threaded pipeline segments connected with a metal coupling were assembled to simulate the threaded connection in the pipeline system. Two PZT patches were mounted on the surface of one pipeline segment and the pipe coupling, respectively. By loosening the threaded connection with different rotation angles, several looseness scenarios were experimentally investigated. For each looseness condition, the developed time reversal-based approach was performed and the corresponding response signal was acquired and analyzed. The experimental results demonstrate that the peak value of the focused signal detected by the PZT sensor decreases with the increase of the looseness degree. The entire test conducted from tightened connection to loosened connection was repeated eight times to validate the repeatability of the developed method and the consistency of the detection results. In addition, the reliability of the developed method was studied by involving high disturbances when the signal was measured. All the test results show that the developed method has a great potential to be employed in practical applications for monitoring the looseness condition of the threaded pipe connection, especially in an environment with severe noises and disturbances.
format Online
Article
Text
id pubmed-6068957
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-60689572018-08-07 Loosening Monitoring of the Threaded Pipe Connection Using Time Reversal Technique and Piezoceramic Transducers Liang, Yabin Feng, Qian Li, Dongsheng Sensors (Basel) Article Threaded pipe connections are commonly used in the oil and gas industry in particular to connect casting strings, drill pipe strings, production and transportation risers, and pipelines. As the most critical components in the entire chain, maintaining a sealed and secure connection while being subjected to environmental loads and pollution is very important and necessary to reduce potential leakage risk and guarantee the safety of the entire chain. In this paper, an effective approach using time reversal technique and lead zirconate titanate (PZT) transducer was developed to monitor the looseness of the threaded pipe connection. Two threaded pipeline segments connected with a metal coupling were assembled to simulate the threaded connection in the pipeline system. Two PZT patches were mounted on the surface of one pipeline segment and the pipe coupling, respectively. By loosening the threaded connection with different rotation angles, several looseness scenarios were experimentally investigated. For each looseness condition, the developed time reversal-based approach was performed and the corresponding response signal was acquired and analyzed. The experimental results demonstrate that the peak value of the focused signal detected by the PZT sensor decreases with the increase of the looseness degree. The entire test conducted from tightened connection to loosened connection was repeated eight times to validate the repeatability of the developed method and the consistency of the detection results. In addition, the reliability of the developed method was studied by involving high disturbances when the signal was measured. All the test results show that the developed method has a great potential to be employed in practical applications for monitoring the looseness condition of the threaded pipe connection, especially in an environment with severe noises and disturbances. MDPI 2018-07-14 /pmc/articles/PMC6068957/ /pubmed/30011914 http://dx.doi.org/10.3390/s18072280 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Liang, Yabin
Feng, Qian
Li, Dongsheng
Loosening Monitoring of the Threaded Pipe Connection Using Time Reversal Technique and Piezoceramic Transducers
title Loosening Monitoring of the Threaded Pipe Connection Using Time Reversal Technique and Piezoceramic Transducers
title_full Loosening Monitoring of the Threaded Pipe Connection Using Time Reversal Technique and Piezoceramic Transducers
title_fullStr Loosening Monitoring of the Threaded Pipe Connection Using Time Reversal Technique and Piezoceramic Transducers
title_full_unstemmed Loosening Monitoring of the Threaded Pipe Connection Using Time Reversal Technique and Piezoceramic Transducers
title_short Loosening Monitoring of the Threaded Pipe Connection Using Time Reversal Technique and Piezoceramic Transducers
title_sort loosening monitoring of the threaded pipe connection using time reversal technique and piezoceramic transducers
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6068957/
https://www.ncbi.nlm.nih.gov/pubmed/30011914
http://dx.doi.org/10.3390/s18072280
work_keys_str_mv AT liangyabin looseningmonitoringofthethreadedpipeconnectionusingtimereversaltechniqueandpiezoceramictransducers
AT fengqian looseningmonitoringofthethreadedpipeconnectionusingtimereversaltechniqueandpiezoceramictransducers
AT lidongsheng looseningmonitoringofthethreadedpipeconnectionusingtimereversaltechniqueandpiezoceramictransducers