Cargando…

Intensity Demodulated Refractive Index Sensor Based on Front-Tapered Single-Mode-Multimode-Single-Mode Fiber Structure

A novel intensity demodulated refractive index (RI) sensor is theoretically and experimentally demonstrated based on the front-tapered single-mode-multimode-single-mode (FT-SMS) fiber structure. The front taper is fabricated in a section of multimode fiber by flame-heated drawing technique. The inte...

Descripción completa

Detalles Bibliográficos
Autores principales: Kang, Jing, Yang, Jiuru, Zhang, Xudong, Liu, Chunyu, Wang, Lu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6069049/
https://www.ncbi.nlm.nih.gov/pubmed/30041487
http://dx.doi.org/10.3390/s18072396
_version_ 1783343408288366592
author Kang, Jing
Yang, Jiuru
Zhang, Xudong
Liu, Chunyu
Wang, Lu
author_facet Kang, Jing
Yang, Jiuru
Zhang, Xudong
Liu, Chunyu
Wang, Lu
author_sort Kang, Jing
collection PubMed
description A novel intensity demodulated refractive index (RI) sensor is theoretically and experimentally demonstrated based on the front-tapered single-mode-multimode-single-mode (FT-SMS) fiber structure. The front taper is fabricated in a section of multimode fiber by flame-heated drawing technique. The intensity feature in the taper area is analyzed through the beam propagation method and the comprehensive tests are then conducted in terms of RI and temperature. The experimental results show that, in FT-SMS, the relative sensitivity is −342.815 dB/RIU in the range of 1.33~1.37. The corresponding resolution reaches 2.92 × 10(−5) RIU, which is more than four times higher than that in wavelength demodulation. The temperature sensitivity is 0.307 dB/°C and the measurement error from cross-sensitivity is less than 2 × 10(−4). In addition, fabricated RI sensor presents high stability in terms of wavelength (±0.045 nm) and intensity (±0.386 dB) within 2 h of continuous operation.
format Online
Article
Text
id pubmed-6069049
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-60690492018-08-07 Intensity Demodulated Refractive Index Sensor Based on Front-Tapered Single-Mode-Multimode-Single-Mode Fiber Structure Kang, Jing Yang, Jiuru Zhang, Xudong Liu, Chunyu Wang, Lu Sensors (Basel) Article A novel intensity demodulated refractive index (RI) sensor is theoretically and experimentally demonstrated based on the front-tapered single-mode-multimode-single-mode (FT-SMS) fiber structure. The front taper is fabricated in a section of multimode fiber by flame-heated drawing technique. The intensity feature in the taper area is analyzed through the beam propagation method and the comprehensive tests are then conducted in terms of RI and temperature. The experimental results show that, in FT-SMS, the relative sensitivity is −342.815 dB/RIU in the range of 1.33~1.37. The corresponding resolution reaches 2.92 × 10(−5) RIU, which is more than four times higher than that in wavelength demodulation. The temperature sensitivity is 0.307 dB/°C and the measurement error from cross-sensitivity is less than 2 × 10(−4). In addition, fabricated RI sensor presents high stability in terms of wavelength (±0.045 nm) and intensity (±0.386 dB) within 2 h of continuous operation. MDPI 2018-07-23 /pmc/articles/PMC6069049/ /pubmed/30041487 http://dx.doi.org/10.3390/s18072396 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Kang, Jing
Yang, Jiuru
Zhang, Xudong
Liu, Chunyu
Wang, Lu
Intensity Demodulated Refractive Index Sensor Based on Front-Tapered Single-Mode-Multimode-Single-Mode Fiber Structure
title Intensity Demodulated Refractive Index Sensor Based on Front-Tapered Single-Mode-Multimode-Single-Mode Fiber Structure
title_full Intensity Demodulated Refractive Index Sensor Based on Front-Tapered Single-Mode-Multimode-Single-Mode Fiber Structure
title_fullStr Intensity Demodulated Refractive Index Sensor Based on Front-Tapered Single-Mode-Multimode-Single-Mode Fiber Structure
title_full_unstemmed Intensity Demodulated Refractive Index Sensor Based on Front-Tapered Single-Mode-Multimode-Single-Mode Fiber Structure
title_short Intensity Demodulated Refractive Index Sensor Based on Front-Tapered Single-Mode-Multimode-Single-Mode Fiber Structure
title_sort intensity demodulated refractive index sensor based on front-tapered single-mode-multimode-single-mode fiber structure
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6069049/
https://www.ncbi.nlm.nih.gov/pubmed/30041487
http://dx.doi.org/10.3390/s18072396
work_keys_str_mv AT kangjing intensitydemodulatedrefractiveindexsensorbasedonfronttaperedsinglemodemultimodesinglemodefiberstructure
AT yangjiuru intensitydemodulatedrefractiveindexsensorbasedonfronttaperedsinglemodemultimodesinglemodefiberstructure
AT zhangxudong intensitydemodulatedrefractiveindexsensorbasedonfronttaperedsinglemodemultimodesinglemodefiberstructure
AT liuchunyu intensitydemodulatedrefractiveindexsensorbasedonfronttaperedsinglemodemultimodesinglemodefiberstructure
AT wanglu intensitydemodulatedrefractiveindexsensorbasedonfronttaperedsinglemodemultimodesinglemodefiberstructure