Cargando…

Lung-thorax compliance measured during a spontaneous breathing trial is a good index of extubation failure in the surgical intensive care unit: a retrospective cohort study

BACKGROUND: Extubation failure is associated with mortality and morbidity in the intensive care unit. Ventilator weaning protocols have been introduced, and extubation is conducted based on the results of a spontaneous breathing trial. Room for improvement still exists in extubation management, and...

Descripción completa

Detalles Bibliográficos
Autores principales: Okabe, Yugo, Asaga, Takehiko, Bekku, Sayuri, Suzuki, Hiromi, Kanda, Kanae, Yoda, Takeshi, Hirao, Tomohiro, Shirakami, Gotaro
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6069862/
https://www.ncbi.nlm.nih.gov/pubmed/30083347
http://dx.doi.org/10.1186/s40560-018-0313-9
_version_ 1783343586821013504
author Okabe, Yugo
Asaga, Takehiko
Bekku, Sayuri
Suzuki, Hiromi
Kanda, Kanae
Yoda, Takeshi
Hirao, Tomohiro
Shirakami, Gotaro
author_facet Okabe, Yugo
Asaga, Takehiko
Bekku, Sayuri
Suzuki, Hiromi
Kanda, Kanae
Yoda, Takeshi
Hirao, Tomohiro
Shirakami, Gotaro
author_sort Okabe, Yugo
collection PubMed
description BACKGROUND: Extubation failure is associated with mortality and morbidity in the intensive care unit. Ventilator weaning protocols have been introduced, and extubation is conducted based on the results of a spontaneous breathing trial. Room for improvement still exists in extubation management, and additional objective indices may improve the safety of the weaning and extubation process. Static lung-thorax compliance reflects lung expansion difficulty that is caused by several conditions, such as atelectasis, fibrosis, and pleural effusion. Nevertheless, it is not used commonly in the weaning and extubation process. In this study, we investigated whether lung-thorax compliance is a good index of extubation failure in adults even when patients pass a spontaneous breathing trial. METHODS: In a single-center, retrospective cohort study, patients over 18 years of age were mechanically ventilated, weaned with proportional assist ventilation, and underwent a spontaneous breathing trial process in surgical intensive care units of Kagawa University Hospital from July 2014 to June 2016. Extubation failure was the outcome measure of the study. We defined extubation failures as when patients were reintubated or underwent non-invasive positive-pressure ventilation within 24 h after extubation. Receiver operating characteristic (ROC) curve analysis was performed to evaluate the clinical involvement of several parameters. The area under the curve (AUC) was calculated to assess the discriminative power of the parameters. RESULTS: We analyzed 173 patients and compared the success and failure groups. Most patients (162, 93.6%) were extubated successfully, and extubation failed in 11 patients (6.4%). The averages of lung-thorax compliance values in the success and failure groups were 71.9 ± 23.0 and 43.3 ± 14.6 mL/cmH(2)O, respectively, and were significantly different (p < 0.0001). In the ROC curve analysis, the AUC was highest for lung-thorax compliance (0.862), followed by the respiratory rate (0.821), rapid shallow breathing index (0.781), Acute Physiology and Chronic Health Evaluation II score (0.72), heart rate (0.715), and tidal volume (0.695). CONCLUSIONS: Lung-thorax compliance measured during a spontaneous breathing trial is a potential indicator of extubation failure in postoperative patients.
format Online
Article
Text
id pubmed-6069862
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-60698622018-08-06 Lung-thorax compliance measured during a spontaneous breathing trial is a good index of extubation failure in the surgical intensive care unit: a retrospective cohort study Okabe, Yugo Asaga, Takehiko Bekku, Sayuri Suzuki, Hiromi Kanda, Kanae Yoda, Takeshi Hirao, Tomohiro Shirakami, Gotaro J Intensive Care Research BACKGROUND: Extubation failure is associated with mortality and morbidity in the intensive care unit. Ventilator weaning protocols have been introduced, and extubation is conducted based on the results of a spontaneous breathing trial. Room for improvement still exists in extubation management, and additional objective indices may improve the safety of the weaning and extubation process. Static lung-thorax compliance reflects lung expansion difficulty that is caused by several conditions, such as atelectasis, fibrosis, and pleural effusion. Nevertheless, it is not used commonly in the weaning and extubation process. In this study, we investigated whether lung-thorax compliance is a good index of extubation failure in adults even when patients pass a spontaneous breathing trial. METHODS: In a single-center, retrospective cohort study, patients over 18 years of age were mechanically ventilated, weaned with proportional assist ventilation, and underwent a spontaneous breathing trial process in surgical intensive care units of Kagawa University Hospital from July 2014 to June 2016. Extubation failure was the outcome measure of the study. We defined extubation failures as when patients were reintubated or underwent non-invasive positive-pressure ventilation within 24 h after extubation. Receiver operating characteristic (ROC) curve analysis was performed to evaluate the clinical involvement of several parameters. The area under the curve (AUC) was calculated to assess the discriminative power of the parameters. RESULTS: We analyzed 173 patients and compared the success and failure groups. Most patients (162, 93.6%) were extubated successfully, and extubation failed in 11 patients (6.4%). The averages of lung-thorax compliance values in the success and failure groups were 71.9 ± 23.0 and 43.3 ± 14.6 mL/cmH(2)O, respectively, and were significantly different (p < 0.0001). In the ROC curve analysis, the AUC was highest for lung-thorax compliance (0.862), followed by the respiratory rate (0.821), rapid shallow breathing index (0.781), Acute Physiology and Chronic Health Evaluation II score (0.72), heart rate (0.715), and tidal volume (0.695). CONCLUSIONS: Lung-thorax compliance measured during a spontaneous breathing trial is a potential indicator of extubation failure in postoperative patients. BioMed Central 2018-07-31 /pmc/articles/PMC6069862/ /pubmed/30083347 http://dx.doi.org/10.1186/s40560-018-0313-9 Text en © The Author(s). 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Okabe, Yugo
Asaga, Takehiko
Bekku, Sayuri
Suzuki, Hiromi
Kanda, Kanae
Yoda, Takeshi
Hirao, Tomohiro
Shirakami, Gotaro
Lung-thorax compliance measured during a spontaneous breathing trial is a good index of extubation failure in the surgical intensive care unit: a retrospective cohort study
title Lung-thorax compliance measured during a spontaneous breathing trial is a good index of extubation failure in the surgical intensive care unit: a retrospective cohort study
title_full Lung-thorax compliance measured during a spontaneous breathing trial is a good index of extubation failure in the surgical intensive care unit: a retrospective cohort study
title_fullStr Lung-thorax compliance measured during a spontaneous breathing trial is a good index of extubation failure in the surgical intensive care unit: a retrospective cohort study
title_full_unstemmed Lung-thorax compliance measured during a spontaneous breathing trial is a good index of extubation failure in the surgical intensive care unit: a retrospective cohort study
title_short Lung-thorax compliance measured during a spontaneous breathing trial is a good index of extubation failure in the surgical intensive care unit: a retrospective cohort study
title_sort lung-thorax compliance measured during a spontaneous breathing trial is a good index of extubation failure in the surgical intensive care unit: a retrospective cohort study
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6069862/
https://www.ncbi.nlm.nih.gov/pubmed/30083347
http://dx.doi.org/10.1186/s40560-018-0313-9
work_keys_str_mv AT okabeyugo lungthoraxcompliancemeasuredduringaspontaneousbreathingtrialisagoodindexofextubationfailureinthesurgicalintensivecareunitaretrospectivecohortstudy
AT asagatakehiko lungthoraxcompliancemeasuredduringaspontaneousbreathingtrialisagoodindexofextubationfailureinthesurgicalintensivecareunitaretrospectivecohortstudy
AT bekkusayuri lungthoraxcompliancemeasuredduringaspontaneousbreathingtrialisagoodindexofextubationfailureinthesurgicalintensivecareunitaretrospectivecohortstudy
AT suzukihiromi lungthoraxcompliancemeasuredduringaspontaneousbreathingtrialisagoodindexofextubationfailureinthesurgicalintensivecareunitaretrospectivecohortstudy
AT kandakanae lungthoraxcompliancemeasuredduringaspontaneousbreathingtrialisagoodindexofextubationfailureinthesurgicalintensivecareunitaretrospectivecohortstudy
AT yodatakeshi lungthoraxcompliancemeasuredduringaspontaneousbreathingtrialisagoodindexofextubationfailureinthesurgicalintensivecareunitaretrospectivecohortstudy
AT hiraotomohiro lungthoraxcompliancemeasuredduringaspontaneousbreathingtrialisagoodindexofextubationfailureinthesurgicalintensivecareunitaretrospectivecohortstudy
AT shirakamigotaro lungthoraxcompliancemeasuredduringaspontaneousbreathingtrialisagoodindexofextubationfailureinthesurgicalintensivecareunitaretrospectivecohortstudy