Cargando…

Inter-comparison of quantitative imaging of lutetium-177 ((177)Lu) in European hospitals

BACKGROUND: This inter-comparison exercise was performed to demonstrate the variability of quantitative SPECT/CT imaging for lutetium-177 ((177)Lu) in current clinical practice. Our aim was to assess the feasibility of using international inter-comparison exercises as a means to ensure consistency b...

Descripción completa

Detalles Bibliográficos
Autores principales: Wevrett, Jill, Fenwick, Andrew, Scuffham, James, Johansson, Lena, Gear, Jonathan, Schlögl, Susanne, Segbers, Marcel, Sjögreen-Gleisner, Katarina, Solný, Pavel, Lassmann, Michael, Tipping, Jill, Nisbet, Andrew
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6070453/
https://www.ncbi.nlm.nih.gov/pubmed/30069805
http://dx.doi.org/10.1186/s40658-018-0213-z
_version_ 1783343666782273536
author Wevrett, Jill
Fenwick, Andrew
Scuffham, James
Johansson, Lena
Gear, Jonathan
Schlögl, Susanne
Segbers, Marcel
Sjögreen-Gleisner, Katarina
Solný, Pavel
Lassmann, Michael
Tipping, Jill
Nisbet, Andrew
author_facet Wevrett, Jill
Fenwick, Andrew
Scuffham, James
Johansson, Lena
Gear, Jonathan
Schlögl, Susanne
Segbers, Marcel
Sjögreen-Gleisner, Katarina
Solný, Pavel
Lassmann, Michael
Tipping, Jill
Nisbet, Andrew
author_sort Wevrett, Jill
collection PubMed
description BACKGROUND: This inter-comparison exercise was performed to demonstrate the variability of quantitative SPECT/CT imaging for lutetium-177 ((177)Lu) in current clinical practice. Our aim was to assess the feasibility of using international inter-comparison exercises as a means to ensure consistency between clinical sites whilst enabling the sites to use their own choice of quantitative imaging protocols, specific to their systems. Dual-compartment concentric spherical sources of accurately known activity concentrations were prepared and sent to seven European clinical sites. The site staff were not aware of the true volumes or activity within the sources—they performed SPECT/CT imaging of the source, positioned within a water-filled phantom, using their own choice of parameters and reported their estimate of the activities within the source. RESULTS: The volumes reported by the participants for the inner section of the source were all within 29% of the true value and within 60% of the true value for the outer section. The activities reported by the participants for the inner section of the source were all within 20% of the true value, whilst those reported for the outer section were up to 83% different to the true value. CONCLUSIONS: A variety of calibration and segmentation methods were used by the participants for this exercise which demonstrated the variability of quantitative imaging across clinical sites. This paper presents a method to assess consistency between sites using different calibration and segmentation methods.
format Online
Article
Text
id pubmed-6070453
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-60704532018-08-20 Inter-comparison of quantitative imaging of lutetium-177 ((177)Lu) in European hospitals Wevrett, Jill Fenwick, Andrew Scuffham, James Johansson, Lena Gear, Jonathan Schlögl, Susanne Segbers, Marcel Sjögreen-Gleisner, Katarina Solný, Pavel Lassmann, Michael Tipping, Jill Nisbet, Andrew EJNMMI Phys Original Research BACKGROUND: This inter-comparison exercise was performed to demonstrate the variability of quantitative SPECT/CT imaging for lutetium-177 ((177)Lu) in current clinical practice. Our aim was to assess the feasibility of using international inter-comparison exercises as a means to ensure consistency between clinical sites whilst enabling the sites to use their own choice of quantitative imaging protocols, specific to their systems. Dual-compartment concentric spherical sources of accurately known activity concentrations were prepared and sent to seven European clinical sites. The site staff were not aware of the true volumes or activity within the sources—they performed SPECT/CT imaging of the source, positioned within a water-filled phantom, using their own choice of parameters and reported their estimate of the activities within the source. RESULTS: The volumes reported by the participants for the inner section of the source were all within 29% of the true value and within 60% of the true value for the outer section. The activities reported by the participants for the inner section of the source were all within 20% of the true value, whilst those reported for the outer section were up to 83% different to the true value. CONCLUSIONS: A variety of calibration and segmentation methods were used by the participants for this exercise which demonstrated the variability of quantitative imaging across clinical sites. This paper presents a method to assess consistency between sites using different calibration and segmentation methods. Springer International Publishing 2018-08-02 /pmc/articles/PMC6070453/ /pubmed/30069805 http://dx.doi.org/10.1186/s40658-018-0213-z Text en © The Author(s). 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Original Research
Wevrett, Jill
Fenwick, Andrew
Scuffham, James
Johansson, Lena
Gear, Jonathan
Schlögl, Susanne
Segbers, Marcel
Sjögreen-Gleisner, Katarina
Solný, Pavel
Lassmann, Michael
Tipping, Jill
Nisbet, Andrew
Inter-comparison of quantitative imaging of lutetium-177 ((177)Lu) in European hospitals
title Inter-comparison of quantitative imaging of lutetium-177 ((177)Lu) in European hospitals
title_full Inter-comparison of quantitative imaging of lutetium-177 ((177)Lu) in European hospitals
title_fullStr Inter-comparison of quantitative imaging of lutetium-177 ((177)Lu) in European hospitals
title_full_unstemmed Inter-comparison of quantitative imaging of lutetium-177 ((177)Lu) in European hospitals
title_short Inter-comparison of quantitative imaging of lutetium-177 ((177)Lu) in European hospitals
title_sort inter-comparison of quantitative imaging of lutetium-177 ((177)lu) in european hospitals
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6070453/
https://www.ncbi.nlm.nih.gov/pubmed/30069805
http://dx.doi.org/10.1186/s40658-018-0213-z
work_keys_str_mv AT wevrettjill intercomparisonofquantitativeimagingoflutetium177177luineuropeanhospitals
AT fenwickandrew intercomparisonofquantitativeimagingoflutetium177177luineuropeanhospitals
AT scuffhamjames intercomparisonofquantitativeimagingoflutetium177177luineuropeanhospitals
AT johanssonlena intercomparisonofquantitativeimagingoflutetium177177luineuropeanhospitals
AT gearjonathan intercomparisonofquantitativeimagingoflutetium177177luineuropeanhospitals
AT schloglsusanne intercomparisonofquantitativeimagingoflutetium177177luineuropeanhospitals
AT segbersmarcel intercomparisonofquantitativeimagingoflutetium177177luineuropeanhospitals
AT sjogreengleisnerkatarina intercomparisonofquantitativeimagingoflutetium177177luineuropeanhospitals
AT solnypavel intercomparisonofquantitativeimagingoflutetium177177luineuropeanhospitals
AT lassmannmichael intercomparisonofquantitativeimagingoflutetium177177luineuropeanhospitals
AT tippingjill intercomparisonofquantitativeimagingoflutetium177177luineuropeanhospitals
AT nisbetandrew intercomparisonofquantitativeimagingoflutetium177177luineuropeanhospitals