Inter-comparison of quantitative imaging of lutetium-177 ((177)Lu) in European hospitals
BACKGROUND: This inter-comparison exercise was performed to demonstrate the variability of quantitative SPECT/CT imaging for lutetium-177 ((177)Lu) in current clinical practice. Our aim was to assess the feasibility of using international inter-comparison exercises as a means to ensure consistency b...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6070453/ https://www.ncbi.nlm.nih.gov/pubmed/30069805 http://dx.doi.org/10.1186/s40658-018-0213-z |
_version_ | 1783343666782273536 |
---|---|
author | Wevrett, Jill Fenwick, Andrew Scuffham, James Johansson, Lena Gear, Jonathan Schlögl, Susanne Segbers, Marcel Sjögreen-Gleisner, Katarina Solný, Pavel Lassmann, Michael Tipping, Jill Nisbet, Andrew |
author_facet | Wevrett, Jill Fenwick, Andrew Scuffham, James Johansson, Lena Gear, Jonathan Schlögl, Susanne Segbers, Marcel Sjögreen-Gleisner, Katarina Solný, Pavel Lassmann, Michael Tipping, Jill Nisbet, Andrew |
author_sort | Wevrett, Jill |
collection | PubMed |
description | BACKGROUND: This inter-comparison exercise was performed to demonstrate the variability of quantitative SPECT/CT imaging for lutetium-177 ((177)Lu) in current clinical practice. Our aim was to assess the feasibility of using international inter-comparison exercises as a means to ensure consistency between clinical sites whilst enabling the sites to use their own choice of quantitative imaging protocols, specific to their systems. Dual-compartment concentric spherical sources of accurately known activity concentrations were prepared and sent to seven European clinical sites. The site staff were not aware of the true volumes or activity within the sources—they performed SPECT/CT imaging of the source, positioned within a water-filled phantom, using their own choice of parameters and reported their estimate of the activities within the source. RESULTS: The volumes reported by the participants for the inner section of the source were all within 29% of the true value and within 60% of the true value for the outer section. The activities reported by the participants for the inner section of the source were all within 20% of the true value, whilst those reported for the outer section were up to 83% different to the true value. CONCLUSIONS: A variety of calibration and segmentation methods were used by the participants for this exercise which demonstrated the variability of quantitative imaging across clinical sites. This paper presents a method to assess consistency between sites using different calibration and segmentation methods. |
format | Online Article Text |
id | pubmed-6070453 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Springer International Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-60704532018-08-20 Inter-comparison of quantitative imaging of lutetium-177 ((177)Lu) in European hospitals Wevrett, Jill Fenwick, Andrew Scuffham, James Johansson, Lena Gear, Jonathan Schlögl, Susanne Segbers, Marcel Sjögreen-Gleisner, Katarina Solný, Pavel Lassmann, Michael Tipping, Jill Nisbet, Andrew EJNMMI Phys Original Research BACKGROUND: This inter-comparison exercise was performed to demonstrate the variability of quantitative SPECT/CT imaging for lutetium-177 ((177)Lu) in current clinical practice. Our aim was to assess the feasibility of using international inter-comparison exercises as a means to ensure consistency between clinical sites whilst enabling the sites to use their own choice of quantitative imaging protocols, specific to their systems. Dual-compartment concentric spherical sources of accurately known activity concentrations were prepared and sent to seven European clinical sites. The site staff were not aware of the true volumes or activity within the sources—they performed SPECT/CT imaging of the source, positioned within a water-filled phantom, using their own choice of parameters and reported their estimate of the activities within the source. RESULTS: The volumes reported by the participants for the inner section of the source were all within 29% of the true value and within 60% of the true value for the outer section. The activities reported by the participants for the inner section of the source were all within 20% of the true value, whilst those reported for the outer section were up to 83% different to the true value. CONCLUSIONS: A variety of calibration and segmentation methods were used by the participants for this exercise which demonstrated the variability of quantitative imaging across clinical sites. This paper presents a method to assess consistency between sites using different calibration and segmentation methods. Springer International Publishing 2018-08-02 /pmc/articles/PMC6070453/ /pubmed/30069805 http://dx.doi.org/10.1186/s40658-018-0213-z Text en © The Author(s). 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Original Research Wevrett, Jill Fenwick, Andrew Scuffham, James Johansson, Lena Gear, Jonathan Schlögl, Susanne Segbers, Marcel Sjögreen-Gleisner, Katarina Solný, Pavel Lassmann, Michael Tipping, Jill Nisbet, Andrew Inter-comparison of quantitative imaging of lutetium-177 ((177)Lu) in European hospitals |
title | Inter-comparison of quantitative imaging of lutetium-177 ((177)Lu) in European hospitals |
title_full | Inter-comparison of quantitative imaging of lutetium-177 ((177)Lu) in European hospitals |
title_fullStr | Inter-comparison of quantitative imaging of lutetium-177 ((177)Lu) in European hospitals |
title_full_unstemmed | Inter-comparison of quantitative imaging of lutetium-177 ((177)Lu) in European hospitals |
title_short | Inter-comparison of quantitative imaging of lutetium-177 ((177)Lu) in European hospitals |
title_sort | inter-comparison of quantitative imaging of lutetium-177 ((177)lu) in european hospitals |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6070453/ https://www.ncbi.nlm.nih.gov/pubmed/30069805 http://dx.doi.org/10.1186/s40658-018-0213-z |
work_keys_str_mv | AT wevrettjill intercomparisonofquantitativeimagingoflutetium177177luineuropeanhospitals AT fenwickandrew intercomparisonofquantitativeimagingoflutetium177177luineuropeanhospitals AT scuffhamjames intercomparisonofquantitativeimagingoflutetium177177luineuropeanhospitals AT johanssonlena intercomparisonofquantitativeimagingoflutetium177177luineuropeanhospitals AT gearjonathan intercomparisonofquantitativeimagingoflutetium177177luineuropeanhospitals AT schloglsusanne intercomparisonofquantitativeimagingoflutetium177177luineuropeanhospitals AT segbersmarcel intercomparisonofquantitativeimagingoflutetium177177luineuropeanhospitals AT sjogreengleisnerkatarina intercomparisonofquantitativeimagingoflutetium177177luineuropeanhospitals AT solnypavel intercomparisonofquantitativeimagingoflutetium177177luineuropeanhospitals AT lassmannmichael intercomparisonofquantitativeimagingoflutetium177177luineuropeanhospitals AT tippingjill intercomparisonofquantitativeimagingoflutetium177177luineuropeanhospitals AT nisbetandrew intercomparisonofquantitativeimagingoflutetium177177luineuropeanhospitals |