Need for a reliable alternative to custom-made Implant Impression trays: An in vitro study comparing accuracy of custom trays versus specialized aluminum stock tray

PURPOSE: The aim of the present study was to evaluate and to compare the accuracy of implant casts obtained by open tray pick-up impression technique using 2 types of custom-made trays and a specialized aluminum stock impression tray. MATERIALS AND METHODS: A heat-cure acrylic resin master model was...

Descripción completa

Detalles Bibliográficos
Autores principales: Goel, Mukti, Dhawan, Pankaj, Tandan, Piyush, Madhukar, Pankaj
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6070855/
https://www.ncbi.nlm.nih.gov/pubmed/30111917
http://dx.doi.org/10.4103/jips.jips_232_17
_version_ 1783343749770772480
author Goel, Mukti
Dhawan, Pankaj
Tandan, Piyush
Madhukar, Pankaj
author_facet Goel, Mukti
Dhawan, Pankaj
Tandan, Piyush
Madhukar, Pankaj
author_sort Goel, Mukti
collection PubMed
description PURPOSE: The aim of the present study was to evaluate and to compare the accuracy of implant casts obtained by open tray pick-up impression technique using 2 types of custom-made trays and a specialized aluminum stock impression tray. MATERIALS AND METHODS: A heat-cure acrylic resin master model was fabricated. Two implants were placed parallel to each other. Ten impressions were made from each group. Polyvinylsiloxane impression material with single step putty wash technique was used for making all the impressions. The resultant casts obtained were compared to the master models with respect to the distances measured between the reference points using a stereomicroscope. The data obtained was statistically analyzed using one-way ANOVA, Tukey's post hoc procedures, and t-test. RESULTS: Mean value obtained was 2.012967 cm (±0.007060) for corimplant stock tray, 2.012627 cm (±0.007945) for autopolymerizing acrylic resin tray, 2.010279 cm (±0.006832) for light-cure hybrid composite tray. P value was calculated to be >0.05; hence, there was nonsignificant deviation of observations from standard value in each group. CONCLUSION: Statistically insignificant difference was found between the accuracy of casts obtained by the different impression trays. However, light-cure hybrid composite trays showed best results followed by autopolymerizing acrylic resin trays and Corimplant stock tray.
format Online
Article
Text
id pubmed-6070855
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-60708552019-07-01 Need for a reliable alternative to custom-made Implant Impression trays: An in vitro study comparing accuracy of custom trays versus specialized aluminum stock tray Goel, Mukti Dhawan, Pankaj Tandan, Piyush Madhukar, Pankaj J Indian Prosthodont Soc Original Article PURPOSE: The aim of the present study was to evaluate and to compare the accuracy of implant casts obtained by open tray pick-up impression technique using 2 types of custom-made trays and a specialized aluminum stock impression tray. MATERIALS AND METHODS: A heat-cure acrylic resin master model was fabricated. Two implants were placed parallel to each other. Ten impressions were made from each group. Polyvinylsiloxane impression material with single step putty wash technique was used for making all the impressions. The resultant casts obtained were compared to the master models with respect to the distances measured between the reference points using a stereomicroscope. The data obtained was statistically analyzed using one-way ANOVA, Tukey's post hoc procedures, and t-test. RESULTS: Mean value obtained was 2.012967 cm (±0.007060) for corimplant stock tray, 2.012627 cm (±0.007945) for autopolymerizing acrylic resin tray, 2.010279 cm (±0.006832) for light-cure hybrid composite tray. P value was calculated to be >0.05; hence, there was nonsignificant deviation of observations from standard value in each group. CONCLUSION: Statistically insignificant difference was found between the accuracy of casts obtained by the different impression trays. However, light-cure hybrid composite trays showed best results followed by autopolymerizing acrylic resin trays and Corimplant stock tray. Medknow Publications & Media Pvt Ltd 2018 /pmc/articles/PMC6070855/ /pubmed/30111917 http://dx.doi.org/10.4103/jips.jips_232_17 Text en Copyright: © 2018 The Journal of Indian Prosthodontic Society http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Goel, Mukti
Dhawan, Pankaj
Tandan, Piyush
Madhukar, Pankaj
Need for a reliable alternative to custom-made Implant Impression trays: An in vitro study comparing accuracy of custom trays versus specialized aluminum stock tray
title Need for a reliable alternative to custom-made Implant Impression trays: An in vitro study comparing accuracy of custom trays versus specialized aluminum stock tray
title_full Need for a reliable alternative to custom-made Implant Impression trays: An in vitro study comparing accuracy of custom trays versus specialized aluminum stock tray
title_fullStr Need for a reliable alternative to custom-made Implant Impression trays: An in vitro study comparing accuracy of custom trays versus specialized aluminum stock tray
title_full_unstemmed Need for a reliable alternative to custom-made Implant Impression trays: An in vitro study comparing accuracy of custom trays versus specialized aluminum stock tray
title_short Need for a reliable alternative to custom-made Implant Impression trays: An in vitro study comparing accuracy of custom trays versus specialized aluminum stock tray
title_sort need for a reliable alternative to custom-made implant impression trays: an in vitro study comparing accuracy of custom trays versus specialized aluminum stock tray
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6070855/
https://www.ncbi.nlm.nih.gov/pubmed/30111917
http://dx.doi.org/10.4103/jips.jips_232_17
work_keys_str_mv AT goelmukti needforareliablealternativetocustommadeimplantimpressiontraysaninvitrostudycomparingaccuracyofcustomtraysversusspecializedaluminumstocktray
AT dhawanpankaj needforareliablealternativetocustommadeimplantimpressiontraysaninvitrostudycomparingaccuracyofcustomtraysversusspecializedaluminumstocktray
AT tandanpiyush needforareliablealternativetocustommadeimplantimpressiontraysaninvitrostudycomparingaccuracyofcustomtraysversusspecializedaluminumstocktray
AT madhukarpankaj needforareliablealternativetocustommadeimplantimpressiontraysaninvitrostudycomparingaccuracyofcustomtraysversusspecializedaluminumstocktray