Cargando…
Aptamer-functionalized AuNPs for the high-sensitivity colorimetric detection of melamine in milk samples
Although aptamer-functionalized AuNPs technology exhibits great potential in analytical and biological chemistry, direct analysis of molecules at a low concentration using colorimetric assay remains challenging. The development of intuitive methods has attracted interest for promising detection of m...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6072046/ https://www.ncbi.nlm.nih.gov/pubmed/30071096 http://dx.doi.org/10.1371/journal.pone.0201626 |
_version_ | 1783343960892112896 |
---|---|
author | Hu, Xinran Chang, Keke Wang, Shun Sun, Xiaoquan Hu, Jiandong Jiang, Min |
author_facet | Hu, Xinran Chang, Keke Wang, Shun Sun, Xiaoquan Hu, Jiandong Jiang, Min |
author_sort | Hu, Xinran |
collection | PubMed |
description | Although aptamer-functionalized AuNPs technology exhibits great potential in analytical and biological chemistry, direct analysis of molecules at a low concentration using colorimetric assay remains challenging. The development of intuitive methods has attracted interest for promising detection of melamine in milk samples due to a demand for stable and understandable process. In this study, we propose a rapid and facile colorimetric measurement method of melamine combined aptamer-functionalized AuNPs in contaminated milk samples. To realize the high stability and the lower limit of detection, the aptamer-functionalized surface of AuNPs via a coordinated bond was used in combination with ultra-sonication. The kinetics of this colorimetric assay based on aptamer-functionalized AuNPs was analyzed to illustrate that the higher the concentration of melamine, the faster the aggregation of AuNPs induced. The sensitivity, selectivity, limit of detection and recovery rate were sufficiently validated to understand the measurement principle of melamine using aptamer-functionalized AuNPs. The calibration curve established by the absorption peak ratio (A640 /A520) was linear in the concentration range of 0~1μM of melamine in aqueous solutions with the correlation coefficient (R(2)) of 0.986 and the limit of detection (LOD) of 22 nM, whereas, the correlation coefficient (R(2)) of 0.998 and the LOD of 14.9 nM were achieved at the concentration of melamine below 0.5 μM in milk samples. The optimized performance of this colorimetric assay of melamine using aptamer-functionalized AuNPs in milk samples was obtained with 100 μL of 13 nm AuNPs solution, 40 μL of 1 μM (100 dilutions) aptamers and the pre-reaction time of 30 min. This simple colorimetric measurement of melamine using aptamer-functionalized AuNPs provides a promising target for various applications of the sample source with complex sample matrices. |
format | Online Article Text |
id | pubmed-6072046 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-60720462018-08-16 Aptamer-functionalized AuNPs for the high-sensitivity colorimetric detection of melamine in milk samples Hu, Xinran Chang, Keke Wang, Shun Sun, Xiaoquan Hu, Jiandong Jiang, Min PLoS One Research Article Although aptamer-functionalized AuNPs technology exhibits great potential in analytical and biological chemistry, direct analysis of molecules at a low concentration using colorimetric assay remains challenging. The development of intuitive methods has attracted interest for promising detection of melamine in milk samples due to a demand for stable and understandable process. In this study, we propose a rapid and facile colorimetric measurement method of melamine combined aptamer-functionalized AuNPs in contaminated milk samples. To realize the high stability and the lower limit of detection, the aptamer-functionalized surface of AuNPs via a coordinated bond was used in combination with ultra-sonication. The kinetics of this colorimetric assay based on aptamer-functionalized AuNPs was analyzed to illustrate that the higher the concentration of melamine, the faster the aggregation of AuNPs induced. The sensitivity, selectivity, limit of detection and recovery rate were sufficiently validated to understand the measurement principle of melamine using aptamer-functionalized AuNPs. The calibration curve established by the absorption peak ratio (A640 /A520) was linear in the concentration range of 0~1μM of melamine in aqueous solutions with the correlation coefficient (R(2)) of 0.986 and the limit of detection (LOD) of 22 nM, whereas, the correlation coefficient (R(2)) of 0.998 and the LOD of 14.9 nM were achieved at the concentration of melamine below 0.5 μM in milk samples. The optimized performance of this colorimetric assay of melamine using aptamer-functionalized AuNPs in milk samples was obtained with 100 μL of 13 nm AuNPs solution, 40 μL of 1 μM (100 dilutions) aptamers and the pre-reaction time of 30 min. This simple colorimetric measurement of melamine using aptamer-functionalized AuNPs provides a promising target for various applications of the sample source with complex sample matrices. Public Library of Science 2018-08-02 /pmc/articles/PMC6072046/ /pubmed/30071096 http://dx.doi.org/10.1371/journal.pone.0201626 Text en © 2018 Hu et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Hu, Xinran Chang, Keke Wang, Shun Sun, Xiaoquan Hu, Jiandong Jiang, Min Aptamer-functionalized AuNPs for the high-sensitivity colorimetric detection of melamine in milk samples |
title | Aptamer-functionalized AuNPs for the high-sensitivity colorimetric detection of melamine in milk samples |
title_full | Aptamer-functionalized AuNPs for the high-sensitivity colorimetric detection of melamine in milk samples |
title_fullStr | Aptamer-functionalized AuNPs for the high-sensitivity colorimetric detection of melamine in milk samples |
title_full_unstemmed | Aptamer-functionalized AuNPs for the high-sensitivity colorimetric detection of melamine in milk samples |
title_short | Aptamer-functionalized AuNPs for the high-sensitivity colorimetric detection of melamine in milk samples |
title_sort | aptamer-functionalized aunps for the high-sensitivity colorimetric detection of melamine in milk samples |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6072046/ https://www.ncbi.nlm.nih.gov/pubmed/30071096 http://dx.doi.org/10.1371/journal.pone.0201626 |
work_keys_str_mv | AT huxinran aptamerfunctionalizedaunpsforthehighsensitivitycolorimetricdetectionofmelamineinmilksamples AT changkeke aptamerfunctionalizedaunpsforthehighsensitivitycolorimetricdetectionofmelamineinmilksamples AT wangshun aptamerfunctionalizedaunpsforthehighsensitivitycolorimetricdetectionofmelamineinmilksamples AT sunxiaoquan aptamerfunctionalizedaunpsforthehighsensitivitycolorimetricdetectionofmelamineinmilksamples AT hujiandong aptamerfunctionalizedaunpsforthehighsensitivitycolorimetricdetectionofmelamineinmilksamples AT jiangmin aptamerfunctionalizedaunpsforthehighsensitivitycolorimetricdetectionofmelamineinmilksamples |