Cargando…

Thermal effect of percutaneous radiofrequency ablation with a clustered electrode for vertebral tumors: In vitro and vivo experiments and clinical application

PURPOSE: To investigate effects and heat distribution of radiofrequency ablation (RFA) on vertebral tumors in vitro and in vivo swine experiments and its clinical application. MATERIALS AND METHODS: RFA was performed on the swine spine in vitro and in vivo for 20 min at 90 °C at the electrode tip, a...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhao, Wei, Peng, Zhao-Hong, Chen, Jin-Zhou, Hu, Ji-Hong, Huang, Jian-Qiang, Jiang, Yong-Neng, Luo, Gang, Yi, Gen-Fa, Wang, Hui, Jin, Shen, Gao, Bu-Lang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6072893/
https://www.ncbi.nlm.nih.gov/pubmed/30094136
http://dx.doi.org/10.1016/j.jbo.2018.07.001
_version_ 1783344081433264128
author Zhao, Wei
Peng, Zhao-Hong
Chen, Jin-Zhou
Hu, Ji-Hong
Huang, Jian-Qiang
Jiang, Yong-Neng
Luo, Gang
Yi, Gen-Fa
Wang, Hui
Jin, Shen
Gao, Bu-Lang
author_facet Zhao, Wei
Peng, Zhao-Hong
Chen, Jin-Zhou
Hu, Ji-Hong
Huang, Jian-Qiang
Jiang, Yong-Neng
Luo, Gang
Yi, Gen-Fa
Wang, Hui
Jin, Shen
Gao, Bu-Lang
author_sort Zhao, Wei
collection PubMed
description PURPOSE: To investigate effects and heat distribution of radiofrequency ablation (RFA) on vertebral tumors in vitro and in vivo swine experiments and its clinical application. MATERIALS AND METHODS: RFA was performed on the swine spine in vitro and in vivo for 20 min at 90 °C at the electrode tip, and the temperature at the electrode tip and surrounding tissues were recorded. Clinical application of ablation combined with vertebroplasty was subsequently performed in 4 patients with spinal tumors. RESULTS: In the in vitro study, the mean temperature at the front and ventral wall of the spinal canal was 50.8 °C and 43.6 °C, respectively, at 20 mm significantly greater than 37.7 °C and 33.7 ± 1.7 °C, respectively, at 10 mm ablation depth. The coagulative necrosis area was significantly (P < 0.0001) greater at 20 mm depth than at 10 mm depth (mean 17.0 × 20.7 mm(2) vs. 14.2 × 16.6 mm(2)). In the in vivo experiment, the local temperature increased significantly (P < 0.05) from around 36 °C before ablation to over 41 °C at 20 min after ablation, with the temperature at the electrode tip (90.4 °C) and within the vertebral body (67.0 °C) significantly (P < 0.05) greater than at the posterior (41.9 °C) and lateral wall (41.8 °C). From 2 to 5 weeks, bone remodeling began. Clinically, all four patients had successful RFA and vertebroplasty, with no neurological deficits. The pain scores were significanlty (P < 0.05) improved before (4.5–10, mean 8.0) compared with at four weeks (0–1.8, mean 1.8). CONCLUSION: The clustered electrode can be efficiently and safely applied in the treatment of spinal tumors without damaging the spinal cord and adjacent nerves by heat distribution.
format Online
Article
Text
id pubmed-6072893
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-60728932018-08-09 Thermal effect of percutaneous radiofrequency ablation with a clustered electrode for vertebral tumors: In vitro and vivo experiments and clinical application Zhao, Wei Peng, Zhao-Hong Chen, Jin-Zhou Hu, Ji-Hong Huang, Jian-Qiang Jiang, Yong-Neng Luo, Gang Yi, Gen-Fa Wang, Hui Jin, Shen Gao, Bu-Lang J Bone Oncol Research Article PURPOSE: To investigate effects and heat distribution of radiofrequency ablation (RFA) on vertebral tumors in vitro and in vivo swine experiments and its clinical application. MATERIALS AND METHODS: RFA was performed on the swine spine in vitro and in vivo for 20 min at 90 °C at the electrode tip, and the temperature at the electrode tip and surrounding tissues were recorded. Clinical application of ablation combined with vertebroplasty was subsequently performed in 4 patients with spinal tumors. RESULTS: In the in vitro study, the mean temperature at the front and ventral wall of the spinal canal was 50.8 °C and 43.6 °C, respectively, at 20 mm significantly greater than 37.7 °C and 33.7 ± 1.7 °C, respectively, at 10 mm ablation depth. The coagulative necrosis area was significantly (P < 0.0001) greater at 20 mm depth than at 10 mm depth (mean 17.0 × 20.7 mm(2) vs. 14.2 × 16.6 mm(2)). In the in vivo experiment, the local temperature increased significantly (P < 0.05) from around 36 °C before ablation to over 41 °C at 20 min after ablation, with the temperature at the electrode tip (90.4 °C) and within the vertebral body (67.0 °C) significantly (P < 0.05) greater than at the posterior (41.9 °C) and lateral wall (41.8 °C). From 2 to 5 weeks, bone remodeling began. Clinically, all four patients had successful RFA and vertebroplasty, with no neurological deficits. The pain scores were significanlty (P < 0.05) improved before (4.5–10, mean 8.0) compared with at four weeks (0–1.8, mean 1.8). CONCLUSION: The clustered electrode can be efficiently and safely applied in the treatment of spinal tumors without damaging the spinal cord and adjacent nerves by heat distribution. Elsevier 2018-07-20 /pmc/articles/PMC6072893/ /pubmed/30094136 http://dx.doi.org/10.1016/j.jbo.2018.07.001 Text en © 2018 The Authors. Published by Elsevier GmbH. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Research Article
Zhao, Wei
Peng, Zhao-Hong
Chen, Jin-Zhou
Hu, Ji-Hong
Huang, Jian-Qiang
Jiang, Yong-Neng
Luo, Gang
Yi, Gen-Fa
Wang, Hui
Jin, Shen
Gao, Bu-Lang
Thermal effect of percutaneous radiofrequency ablation with a clustered electrode for vertebral tumors: In vitro and vivo experiments and clinical application
title Thermal effect of percutaneous radiofrequency ablation with a clustered electrode for vertebral tumors: In vitro and vivo experiments and clinical application
title_full Thermal effect of percutaneous radiofrequency ablation with a clustered electrode for vertebral tumors: In vitro and vivo experiments and clinical application
title_fullStr Thermal effect of percutaneous radiofrequency ablation with a clustered electrode for vertebral tumors: In vitro and vivo experiments and clinical application
title_full_unstemmed Thermal effect of percutaneous radiofrequency ablation with a clustered electrode for vertebral tumors: In vitro and vivo experiments and clinical application
title_short Thermal effect of percutaneous radiofrequency ablation with a clustered electrode for vertebral tumors: In vitro and vivo experiments and clinical application
title_sort thermal effect of percutaneous radiofrequency ablation with a clustered electrode for vertebral tumors: in vitro and vivo experiments and clinical application
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6072893/
https://www.ncbi.nlm.nih.gov/pubmed/30094136
http://dx.doi.org/10.1016/j.jbo.2018.07.001
work_keys_str_mv AT zhaowei thermaleffectofpercutaneousradiofrequencyablationwithaclusteredelectrodeforvertebraltumorsinvitroandvivoexperimentsandclinicalapplication
AT pengzhaohong thermaleffectofpercutaneousradiofrequencyablationwithaclusteredelectrodeforvertebraltumorsinvitroandvivoexperimentsandclinicalapplication
AT chenjinzhou thermaleffectofpercutaneousradiofrequencyablationwithaclusteredelectrodeforvertebraltumorsinvitroandvivoexperimentsandclinicalapplication
AT hujihong thermaleffectofpercutaneousradiofrequencyablationwithaclusteredelectrodeforvertebraltumorsinvitroandvivoexperimentsandclinicalapplication
AT huangjianqiang thermaleffectofpercutaneousradiofrequencyablationwithaclusteredelectrodeforvertebraltumorsinvitroandvivoexperimentsandclinicalapplication
AT jiangyongneng thermaleffectofpercutaneousradiofrequencyablationwithaclusteredelectrodeforvertebraltumorsinvitroandvivoexperimentsandclinicalapplication
AT luogang thermaleffectofpercutaneousradiofrequencyablationwithaclusteredelectrodeforvertebraltumorsinvitroandvivoexperimentsandclinicalapplication
AT yigenfa thermaleffectofpercutaneousradiofrequencyablationwithaclusteredelectrodeforvertebraltumorsinvitroandvivoexperimentsandclinicalapplication
AT wanghui thermaleffectofpercutaneousradiofrequencyablationwithaclusteredelectrodeforvertebraltumorsinvitroandvivoexperimentsandclinicalapplication
AT jinshen thermaleffectofpercutaneousradiofrequencyablationwithaclusteredelectrodeforvertebraltumorsinvitroandvivoexperimentsandclinicalapplication
AT gaobulang thermaleffectofpercutaneousradiofrequencyablationwithaclusteredelectrodeforvertebraltumorsinvitroandvivoexperimentsandclinicalapplication