Biomechanical effect of bone resorption of the spinous process after single-segment interspinous dynamic stabilization device implantation: A finite element analysis
This study aims to explore the influence of bone resorption of the spinous process after single-segment interspinous process device (IPD) implantation on the biomechanics of the lumbar spine. The 3D finite element model of the lumbar spine (L3-L5) was modified, and 2 models that simulated the presen...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer Health
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6076163/ https://www.ncbi.nlm.nih.gov/pubmed/29979380 http://dx.doi.org/10.1097/MD.0000000000011140 |
_version_ | 1783344657536647168 |
---|---|
author | Zhu, Zhen-Qi Duan, Shuo Wang, Kai-Feng Liu, Hai-Ying Xu, Shuai Liu, Chen-Jun |
author_facet | Zhu, Zhen-Qi Duan, Shuo Wang, Kai-Feng Liu, Hai-Ying Xu, Shuai Liu, Chen-Jun |
author_sort | Zhu, Zhen-Qi |
collection | PubMed |
description | This study aims to explore the influence of bone resorption of the spinous process after single-segment interspinous process device (IPD) implantation on the biomechanics of the lumbar spine. The 3D finite element model of the lumbar spine (L3-L5) was modified, and 2 models that simulated the presence and absence of bone resorption of the spinous process were developed using an IPD (Wallis). Its biomechanical effects, such as change in range of motion (ROM) and intervertebral disc and facet stress, were introduced at operative (L4/5) and adjacent (L3/4) levels. Compared with the INT model, the Wallis model and Wallis-BR model had similar ROMs in lateral flexion and rotation. However, the Wallis model had a lower L3–5 ROM in flexion (20.4% lower) and extension (26.4% lower), and L4-L5 ROM in flexion (74.1% lower) and extension (70.8% lower), while the overall ROM of the Wallis-BR model was greater than that of the Wallis model. The stress on the L3/L4 intervertebral disc and facets was similar for all 3 models. Compared with the INT model and Wallis-BR model, the stress on the L4/L5 intervertebral disc and facets under all movements significantly decreased in the Wallis model. The stress on the L5 process was greater than that on the L4 process in both the Wallis model and Wallis-BR model, and the load on the processes that underwent bone resorption was lower than that of the Wallis model. The function of the IPD slowly decreased with the occurrence of bone resorption of the interspinous process. This bone remodeling may be associated with high stress after IPD implantation. |
format | Online Article Text |
id | pubmed-6076163 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Wolters Kluwer Health |
record_format | MEDLINE/PubMed |
spelling | pubmed-60761632018-08-17 Biomechanical effect of bone resorption of the spinous process after single-segment interspinous dynamic stabilization device implantation: A finite element analysis Zhu, Zhen-Qi Duan, Shuo Wang, Kai-Feng Liu, Hai-Ying Xu, Shuai Liu, Chen-Jun Medicine (Baltimore) Research Article This study aims to explore the influence of bone resorption of the spinous process after single-segment interspinous process device (IPD) implantation on the biomechanics of the lumbar spine. The 3D finite element model of the lumbar spine (L3-L5) was modified, and 2 models that simulated the presence and absence of bone resorption of the spinous process were developed using an IPD (Wallis). Its biomechanical effects, such as change in range of motion (ROM) and intervertebral disc and facet stress, were introduced at operative (L4/5) and adjacent (L3/4) levels. Compared with the INT model, the Wallis model and Wallis-BR model had similar ROMs in lateral flexion and rotation. However, the Wallis model had a lower L3–5 ROM in flexion (20.4% lower) and extension (26.4% lower), and L4-L5 ROM in flexion (74.1% lower) and extension (70.8% lower), while the overall ROM of the Wallis-BR model was greater than that of the Wallis model. The stress on the L3/L4 intervertebral disc and facets was similar for all 3 models. Compared with the INT model and Wallis-BR model, the stress on the L4/L5 intervertebral disc and facets under all movements significantly decreased in the Wallis model. The stress on the L5 process was greater than that on the L4 process in both the Wallis model and Wallis-BR model, and the load on the processes that underwent bone resorption was lower than that of the Wallis model. The function of the IPD slowly decreased with the occurrence of bone resorption of the interspinous process. This bone remodeling may be associated with high stress after IPD implantation. Wolters Kluwer Health 2018-07-06 /pmc/articles/PMC6076163/ /pubmed/29979380 http://dx.doi.org/10.1097/MD.0000000000011140 Text en Copyright © 2018 the Author(s). Published by Wolters Kluwer Health, Inc. http://creativecommons.org/licenses/by-nc-nd/4.0 This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0 |
spellingShingle | Research Article Zhu, Zhen-Qi Duan, Shuo Wang, Kai-Feng Liu, Hai-Ying Xu, Shuai Liu, Chen-Jun Biomechanical effect of bone resorption of the spinous process after single-segment interspinous dynamic stabilization device implantation: A finite element analysis |
title | Biomechanical effect of bone resorption of the spinous process after single-segment interspinous dynamic stabilization device implantation: A finite element analysis |
title_full | Biomechanical effect of bone resorption of the spinous process after single-segment interspinous dynamic stabilization device implantation: A finite element analysis |
title_fullStr | Biomechanical effect of bone resorption of the spinous process after single-segment interspinous dynamic stabilization device implantation: A finite element analysis |
title_full_unstemmed | Biomechanical effect of bone resorption of the spinous process after single-segment interspinous dynamic stabilization device implantation: A finite element analysis |
title_short | Biomechanical effect of bone resorption of the spinous process after single-segment interspinous dynamic stabilization device implantation: A finite element analysis |
title_sort | biomechanical effect of bone resorption of the spinous process after single-segment interspinous dynamic stabilization device implantation: a finite element analysis |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6076163/ https://www.ncbi.nlm.nih.gov/pubmed/29979380 http://dx.doi.org/10.1097/MD.0000000000011140 |
work_keys_str_mv | AT zhuzhenqi biomechanicaleffectofboneresorptionofthespinousprocessaftersinglesegmentinterspinousdynamicstabilizationdeviceimplantationafiniteelementanalysis AT duanshuo biomechanicaleffectofboneresorptionofthespinousprocessaftersinglesegmentinterspinousdynamicstabilizationdeviceimplantationafiniteelementanalysis AT wangkaifeng biomechanicaleffectofboneresorptionofthespinousprocessaftersinglesegmentinterspinousdynamicstabilizationdeviceimplantationafiniteelementanalysis AT liuhaiying biomechanicaleffectofboneresorptionofthespinousprocessaftersinglesegmentinterspinousdynamicstabilizationdeviceimplantationafiniteelementanalysis AT xushuai biomechanicaleffectofboneresorptionofthespinousprocessaftersinglesegmentinterspinousdynamicstabilizationdeviceimplantationafiniteelementanalysis AT liuchenjun biomechanicaleffectofboneresorptionofthespinousprocessaftersinglesegmentinterspinousdynamicstabilizationdeviceimplantationafiniteelementanalysis |