Cargando…

The possibilities of a portable low-budget three-dimensional stereophotogrammetry system in neonates: a prospective growth analysis and analysis of accuracy

BACKGROUND: With the technical development, portable three-dimensional (3D) photogrammetry systems are becoming more en vogue because of cost-effectiveness and comparable accuracy to common stationary 3D systems. The purpose of the study was to evaluate the feasibility and accuracy of a low-budget p...

Descripción completa

Detalles Bibliográficos
Autores principales: Ritschl, Lucas M., Roth, Maximilian, Fichter, Andreas M., Mittermeier, Fabienna, Kuschel, Bettina, Wolff, Klaus-Dietrich, Grill, Florian D., Loeffelbein, Denys J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6076401/
https://www.ncbi.nlm.nih.gov/pubmed/30075821
http://dx.doi.org/10.1186/s13005-018-0168-2
_version_ 1783344707271655424
author Ritschl, Lucas M.
Roth, Maximilian
Fichter, Andreas M.
Mittermeier, Fabienna
Kuschel, Bettina
Wolff, Klaus-Dietrich
Grill, Florian D.
Loeffelbein, Denys J.
author_facet Ritschl, Lucas M.
Roth, Maximilian
Fichter, Andreas M.
Mittermeier, Fabienna
Kuschel, Bettina
Wolff, Klaus-Dietrich
Grill, Florian D.
Loeffelbein, Denys J.
author_sort Ritschl, Lucas M.
collection PubMed
description BACKGROUND: With the technical development, portable three-dimensional (3D) photogrammetry systems are becoming more en vogue because of cost-effectiveness and comparable accuracy to common stationary 3D systems. The purpose of the study was to evaluate the feasibility and accuracy of a low-budget portable system for 3D image acquisition with special regard to the gracile nasal region in neonates. Furthermore, the study aimed to establish a 3D data set of the first 180 days post partum. METHODS: Thirty-three healthy, full-term newborn were enrolled and 3D photographs were prospectively taken monthly with a portable low-budget 3D stereophotogrammetry system (FUEL3D® SCANIFY®) for six months. In the third month, age-matched and corresponding 3D models were acquired by taking an impression of the perinasal area. The resulting plaster models were scanned (3Shape D700, 3Shape® A/S, Denmark). Three examiners analyzed independently 21 defined landmarks of the generated Standard Tessellation Language files with regard to accuracy by using 3dMDvultus™ software. A semi-automatic 3D best-fit analysis of 3D photo and plaster models were performed by using Geomagic® and the Root Mean Squared (RMS) errors were calculated. RESULTS: Statistically significant changes of midfacial distances and angles with a focus on nasal growth during the first 180 days postpartum could be specified in absolute and relative dimensions. Best-fit analysis in the third month revealed a RMS error of 0.72 ± 0.22 mm with a mean standard deviation of 0.71 ± 0.21 mm. CONCLUSIONS: The analyzed portable 3D stereophotogrammetry system is a feasible methodology with good accuracy, even in newborn. A description of the growth as well as the establishment of a 3D data set was performed. Its implementation for basic documentation for example in cleft patients is possible and might reduce the need for impressions and facilitate the communications with parents and the interdisciplinary team.
format Online
Article
Text
id pubmed-6076401
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-60764012018-08-07 The possibilities of a portable low-budget three-dimensional stereophotogrammetry system in neonates: a prospective growth analysis and analysis of accuracy Ritschl, Lucas M. Roth, Maximilian Fichter, Andreas M. Mittermeier, Fabienna Kuschel, Bettina Wolff, Klaus-Dietrich Grill, Florian D. Loeffelbein, Denys J. Head Face Med Research BACKGROUND: With the technical development, portable three-dimensional (3D) photogrammetry systems are becoming more en vogue because of cost-effectiveness and comparable accuracy to common stationary 3D systems. The purpose of the study was to evaluate the feasibility and accuracy of a low-budget portable system for 3D image acquisition with special regard to the gracile nasal region in neonates. Furthermore, the study aimed to establish a 3D data set of the first 180 days post partum. METHODS: Thirty-three healthy, full-term newborn were enrolled and 3D photographs were prospectively taken monthly with a portable low-budget 3D stereophotogrammetry system (FUEL3D® SCANIFY®) for six months. In the third month, age-matched and corresponding 3D models were acquired by taking an impression of the perinasal area. The resulting plaster models were scanned (3Shape D700, 3Shape® A/S, Denmark). Three examiners analyzed independently 21 defined landmarks of the generated Standard Tessellation Language files with regard to accuracy by using 3dMDvultus™ software. A semi-automatic 3D best-fit analysis of 3D photo and plaster models were performed by using Geomagic® and the Root Mean Squared (RMS) errors were calculated. RESULTS: Statistically significant changes of midfacial distances and angles with a focus on nasal growth during the first 180 days postpartum could be specified in absolute and relative dimensions. Best-fit analysis in the third month revealed a RMS error of 0.72 ± 0.22 mm with a mean standard deviation of 0.71 ± 0.21 mm. CONCLUSIONS: The analyzed portable 3D stereophotogrammetry system is a feasible methodology with good accuracy, even in newborn. A description of the growth as well as the establishment of a 3D data set was performed. Its implementation for basic documentation for example in cleft patients is possible and might reduce the need for impressions and facilitate the communications with parents and the interdisciplinary team. BioMed Central 2018-08-03 /pmc/articles/PMC6076401/ /pubmed/30075821 http://dx.doi.org/10.1186/s13005-018-0168-2 Text en © The Author(s). 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Ritschl, Lucas M.
Roth, Maximilian
Fichter, Andreas M.
Mittermeier, Fabienna
Kuschel, Bettina
Wolff, Klaus-Dietrich
Grill, Florian D.
Loeffelbein, Denys J.
The possibilities of a portable low-budget three-dimensional stereophotogrammetry system in neonates: a prospective growth analysis and analysis of accuracy
title The possibilities of a portable low-budget three-dimensional stereophotogrammetry system in neonates: a prospective growth analysis and analysis of accuracy
title_full The possibilities of a portable low-budget three-dimensional stereophotogrammetry system in neonates: a prospective growth analysis and analysis of accuracy
title_fullStr The possibilities of a portable low-budget three-dimensional stereophotogrammetry system in neonates: a prospective growth analysis and analysis of accuracy
title_full_unstemmed The possibilities of a portable low-budget three-dimensional stereophotogrammetry system in neonates: a prospective growth analysis and analysis of accuracy
title_short The possibilities of a portable low-budget three-dimensional stereophotogrammetry system in neonates: a prospective growth analysis and analysis of accuracy
title_sort possibilities of a portable low-budget three-dimensional stereophotogrammetry system in neonates: a prospective growth analysis and analysis of accuracy
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6076401/
https://www.ncbi.nlm.nih.gov/pubmed/30075821
http://dx.doi.org/10.1186/s13005-018-0168-2
work_keys_str_mv AT ritschllucasm thepossibilitiesofaportablelowbudgetthreedimensionalstereophotogrammetrysysteminneonatesaprospectivegrowthanalysisandanalysisofaccuracy
AT rothmaximilian thepossibilitiesofaportablelowbudgetthreedimensionalstereophotogrammetrysysteminneonatesaprospectivegrowthanalysisandanalysisofaccuracy
AT fichterandreasm thepossibilitiesofaportablelowbudgetthreedimensionalstereophotogrammetrysysteminneonatesaprospectivegrowthanalysisandanalysisofaccuracy
AT mittermeierfabienna thepossibilitiesofaportablelowbudgetthreedimensionalstereophotogrammetrysysteminneonatesaprospectivegrowthanalysisandanalysisofaccuracy
AT kuschelbettina thepossibilitiesofaportablelowbudgetthreedimensionalstereophotogrammetrysysteminneonatesaprospectivegrowthanalysisandanalysisofaccuracy
AT wolffklausdietrich thepossibilitiesofaportablelowbudgetthreedimensionalstereophotogrammetrysysteminneonatesaprospectivegrowthanalysisandanalysisofaccuracy
AT grillfloriand thepossibilitiesofaportablelowbudgetthreedimensionalstereophotogrammetrysysteminneonatesaprospectivegrowthanalysisandanalysisofaccuracy
AT loeffelbeindenysj thepossibilitiesofaportablelowbudgetthreedimensionalstereophotogrammetrysysteminneonatesaprospectivegrowthanalysisandanalysisofaccuracy
AT ritschllucasm possibilitiesofaportablelowbudgetthreedimensionalstereophotogrammetrysysteminneonatesaprospectivegrowthanalysisandanalysisofaccuracy
AT rothmaximilian possibilitiesofaportablelowbudgetthreedimensionalstereophotogrammetrysysteminneonatesaprospectivegrowthanalysisandanalysisofaccuracy
AT fichterandreasm possibilitiesofaportablelowbudgetthreedimensionalstereophotogrammetrysysteminneonatesaprospectivegrowthanalysisandanalysisofaccuracy
AT mittermeierfabienna possibilitiesofaportablelowbudgetthreedimensionalstereophotogrammetrysysteminneonatesaprospectivegrowthanalysisandanalysisofaccuracy
AT kuschelbettina possibilitiesofaportablelowbudgetthreedimensionalstereophotogrammetrysysteminneonatesaprospectivegrowthanalysisandanalysisofaccuracy
AT wolffklausdietrich possibilitiesofaportablelowbudgetthreedimensionalstereophotogrammetrysysteminneonatesaprospectivegrowthanalysisandanalysisofaccuracy
AT grillfloriand possibilitiesofaportablelowbudgetthreedimensionalstereophotogrammetrysysteminneonatesaprospectivegrowthanalysisandanalysisofaccuracy
AT loeffelbeindenysj possibilitiesofaportablelowbudgetthreedimensionalstereophotogrammetrysysteminneonatesaprospectivegrowthanalysisandanalysisofaccuracy