Cargando…

Graft choice for anatomic anterior cruciate ligament reconstruction: The comparison between thin autograft and thick hybrid graft. An observational study

Great controversy over the graft choice has been lasted now. This study compared the second-look evaluation and clinical outcomes of anatomic anterior cruciate ligament reconstruction (ACL-R) using a thin autograft versus a thick hybrid graft. Seventy-six patients with complete follow-up data were c...

Descripción completa

Detalles Bibliográficos
Autores principales: Xu, Hongtao, Lin, Weiwei, Jin, Guorong, Xin, Dongmei, Zhang, Jian, Kang, Kai, Dong, Jiangtao, Gao, Shijun, Chen, Baicheng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer Health 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6078656/
https://www.ncbi.nlm.nih.gov/pubmed/30045294
http://dx.doi.org/10.1097/MD.0000000000011597
_version_ 1783345127761117184
author Xu, Hongtao
Lin, Weiwei
Jin, Guorong
Xin, Dongmei
Zhang, Jian
Kang, Kai
Dong, Jiangtao
Gao, Shijun
Chen, Baicheng
author_facet Xu, Hongtao
Lin, Weiwei
Jin, Guorong
Xin, Dongmei
Zhang, Jian
Kang, Kai
Dong, Jiangtao
Gao, Shijun
Chen, Baicheng
author_sort Xu, Hongtao
collection PubMed
description Great controversy over the graft choice has been lasted now. This study compared the second-look evaluation and clinical outcomes of anatomic anterior cruciate ligament reconstruction (ACL-R) using a thin autograft versus a thick hybrid graft. Seventy-six patients with complete follow-up data were categorized into the autograft group (N = 34) and hybrid group (N = 42). The Lysholm score, Tegner activity level, International Knee Documentation Committee (IKDC) Knee Evaluation Form, and KT-1000 test were performed before and at follow-up. Results were compared, and further comparisons were made for grafts thicker than 8.5 mm. The hybrid graft was thicker than the autograft (9.10 ± 0.52 vs 8.57 ± 0.48 mm, P < .001). The KT-1000 test, subjective evaluation, and activity level scores increased significantly between pre- and postoperation for all patients (P < .001). No significant differences were, however, found between the 2 groups. Only grafts thicker than 8.5 mm were selected from the autograft (N = 14) and hybrid (N = 34) groups, the Lysholm, IKDC, and KT-1000 test scores were significantly superior for the autograft than the hybrid graft (P = .021, P = .005, and P = .024, respectively). For anatomic ACL-R, a pure autograft is superior to a hybrid graft of the same diameter. The purity of the autograft was more important than the size, and augmenting allografts may be unnecessary.
format Online
Article
Text
id pubmed-6078656
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Wolters Kluwer Health
record_format MEDLINE/PubMed
spelling pubmed-60786562018-08-13 Graft choice for anatomic anterior cruciate ligament reconstruction: The comparison between thin autograft and thick hybrid graft. An observational study Xu, Hongtao Lin, Weiwei Jin, Guorong Xin, Dongmei Zhang, Jian Kang, Kai Dong, Jiangtao Gao, Shijun Chen, Baicheng Medicine (Baltimore) Research Article Great controversy over the graft choice has been lasted now. This study compared the second-look evaluation and clinical outcomes of anatomic anterior cruciate ligament reconstruction (ACL-R) using a thin autograft versus a thick hybrid graft. Seventy-six patients with complete follow-up data were categorized into the autograft group (N = 34) and hybrid group (N = 42). The Lysholm score, Tegner activity level, International Knee Documentation Committee (IKDC) Knee Evaluation Form, and KT-1000 test were performed before and at follow-up. Results were compared, and further comparisons were made for grafts thicker than 8.5 mm. The hybrid graft was thicker than the autograft (9.10 ± 0.52 vs 8.57 ± 0.48 mm, P < .001). The KT-1000 test, subjective evaluation, and activity level scores increased significantly between pre- and postoperation for all patients (P < .001). No significant differences were, however, found between the 2 groups. Only grafts thicker than 8.5 mm were selected from the autograft (N = 14) and hybrid (N = 34) groups, the Lysholm, IKDC, and KT-1000 test scores were significantly superior for the autograft than the hybrid graft (P = .021, P = .005, and P = .024, respectively). For anatomic ACL-R, a pure autograft is superior to a hybrid graft of the same diameter. The purity of the autograft was more important than the size, and augmenting allografts may be unnecessary. Wolters Kluwer Health 2018-07-27 /pmc/articles/PMC6078656/ /pubmed/30045294 http://dx.doi.org/10.1097/MD.0000000000011597 Text en Copyright © 2018 the Author(s). Published by Wolters Kluwer Health, Inc. http://creativecommons.org/licenses/by-nd/4.0 This is an open access article distributed under the Creative Commons Attribution-NoDerivatives License 4.0, which allows for redistribution, commercial and non-commercial, as long as it is passed along unchanged and in whole, with credit to the author. http://creativecommons.org/licenses/by-nd/4.0
spellingShingle Research Article
Xu, Hongtao
Lin, Weiwei
Jin, Guorong
Xin, Dongmei
Zhang, Jian
Kang, Kai
Dong, Jiangtao
Gao, Shijun
Chen, Baicheng
Graft choice for anatomic anterior cruciate ligament reconstruction: The comparison between thin autograft and thick hybrid graft. An observational study
title Graft choice for anatomic anterior cruciate ligament reconstruction: The comparison between thin autograft and thick hybrid graft. An observational study
title_full Graft choice for anatomic anterior cruciate ligament reconstruction: The comparison between thin autograft and thick hybrid graft. An observational study
title_fullStr Graft choice for anatomic anterior cruciate ligament reconstruction: The comparison between thin autograft and thick hybrid graft. An observational study
title_full_unstemmed Graft choice for anatomic anterior cruciate ligament reconstruction: The comparison between thin autograft and thick hybrid graft. An observational study
title_short Graft choice for anatomic anterior cruciate ligament reconstruction: The comparison between thin autograft and thick hybrid graft. An observational study
title_sort graft choice for anatomic anterior cruciate ligament reconstruction: the comparison between thin autograft and thick hybrid graft. an observational study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6078656/
https://www.ncbi.nlm.nih.gov/pubmed/30045294
http://dx.doi.org/10.1097/MD.0000000000011597
work_keys_str_mv AT xuhongtao graftchoiceforanatomicanteriorcruciateligamentreconstructionthecomparisonbetweenthinautograftandthickhybridgraftanobservationalstudy
AT linweiwei graftchoiceforanatomicanteriorcruciateligamentreconstructionthecomparisonbetweenthinautograftandthickhybridgraftanobservationalstudy
AT jinguorong graftchoiceforanatomicanteriorcruciateligamentreconstructionthecomparisonbetweenthinautograftandthickhybridgraftanobservationalstudy
AT xindongmei graftchoiceforanatomicanteriorcruciateligamentreconstructionthecomparisonbetweenthinautograftandthickhybridgraftanobservationalstudy
AT zhangjian graftchoiceforanatomicanteriorcruciateligamentreconstructionthecomparisonbetweenthinautograftandthickhybridgraftanobservationalstudy
AT kangkai graftchoiceforanatomicanteriorcruciateligamentreconstructionthecomparisonbetweenthinautograftandthickhybridgraftanobservationalstudy
AT dongjiangtao graftchoiceforanatomicanteriorcruciateligamentreconstructionthecomparisonbetweenthinautograftandthickhybridgraftanobservationalstudy
AT gaoshijun graftchoiceforanatomicanteriorcruciateligamentreconstructionthecomparisonbetweenthinautograftandthickhybridgraftanobservationalstudy
AT chenbaicheng graftchoiceforanatomicanteriorcruciateligamentreconstructionthecomparisonbetweenthinautograftandthickhybridgraftanobservationalstudy