Cargando…
Graft choice for anatomic anterior cruciate ligament reconstruction: The comparison between thin autograft and thick hybrid graft. An observational study
Great controversy over the graft choice has been lasted now. This study compared the second-look evaluation and clinical outcomes of anatomic anterior cruciate ligament reconstruction (ACL-R) using a thin autograft versus a thick hybrid graft. Seventy-six patients with complete follow-up data were c...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer Health
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6078656/ https://www.ncbi.nlm.nih.gov/pubmed/30045294 http://dx.doi.org/10.1097/MD.0000000000011597 |
_version_ | 1783345127761117184 |
---|---|
author | Xu, Hongtao Lin, Weiwei Jin, Guorong Xin, Dongmei Zhang, Jian Kang, Kai Dong, Jiangtao Gao, Shijun Chen, Baicheng |
author_facet | Xu, Hongtao Lin, Weiwei Jin, Guorong Xin, Dongmei Zhang, Jian Kang, Kai Dong, Jiangtao Gao, Shijun Chen, Baicheng |
author_sort | Xu, Hongtao |
collection | PubMed |
description | Great controversy over the graft choice has been lasted now. This study compared the second-look evaluation and clinical outcomes of anatomic anterior cruciate ligament reconstruction (ACL-R) using a thin autograft versus a thick hybrid graft. Seventy-six patients with complete follow-up data were categorized into the autograft group (N = 34) and hybrid group (N = 42). The Lysholm score, Tegner activity level, International Knee Documentation Committee (IKDC) Knee Evaluation Form, and KT-1000 test were performed before and at follow-up. Results were compared, and further comparisons were made for grafts thicker than 8.5 mm. The hybrid graft was thicker than the autograft (9.10 ± 0.52 vs 8.57 ± 0.48 mm, P < .001). The KT-1000 test, subjective evaluation, and activity level scores increased significantly between pre- and postoperation for all patients (P < .001). No significant differences were, however, found between the 2 groups. Only grafts thicker than 8.5 mm were selected from the autograft (N = 14) and hybrid (N = 34) groups, the Lysholm, IKDC, and KT-1000 test scores were significantly superior for the autograft than the hybrid graft (P = .021, P = .005, and P = .024, respectively). For anatomic ACL-R, a pure autograft is superior to a hybrid graft of the same diameter. The purity of the autograft was more important than the size, and augmenting allografts may be unnecessary. |
format | Online Article Text |
id | pubmed-6078656 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Wolters Kluwer Health |
record_format | MEDLINE/PubMed |
spelling | pubmed-60786562018-08-13 Graft choice for anatomic anterior cruciate ligament reconstruction: The comparison between thin autograft and thick hybrid graft. An observational study Xu, Hongtao Lin, Weiwei Jin, Guorong Xin, Dongmei Zhang, Jian Kang, Kai Dong, Jiangtao Gao, Shijun Chen, Baicheng Medicine (Baltimore) Research Article Great controversy over the graft choice has been lasted now. This study compared the second-look evaluation and clinical outcomes of anatomic anterior cruciate ligament reconstruction (ACL-R) using a thin autograft versus a thick hybrid graft. Seventy-six patients with complete follow-up data were categorized into the autograft group (N = 34) and hybrid group (N = 42). The Lysholm score, Tegner activity level, International Knee Documentation Committee (IKDC) Knee Evaluation Form, and KT-1000 test were performed before and at follow-up. Results were compared, and further comparisons were made for grafts thicker than 8.5 mm. The hybrid graft was thicker than the autograft (9.10 ± 0.52 vs 8.57 ± 0.48 mm, P < .001). The KT-1000 test, subjective evaluation, and activity level scores increased significantly between pre- and postoperation for all patients (P < .001). No significant differences were, however, found between the 2 groups. Only grafts thicker than 8.5 mm were selected from the autograft (N = 14) and hybrid (N = 34) groups, the Lysholm, IKDC, and KT-1000 test scores were significantly superior for the autograft than the hybrid graft (P = .021, P = .005, and P = .024, respectively). For anatomic ACL-R, a pure autograft is superior to a hybrid graft of the same diameter. The purity of the autograft was more important than the size, and augmenting allografts may be unnecessary. Wolters Kluwer Health 2018-07-27 /pmc/articles/PMC6078656/ /pubmed/30045294 http://dx.doi.org/10.1097/MD.0000000000011597 Text en Copyright © 2018 the Author(s). Published by Wolters Kluwer Health, Inc. http://creativecommons.org/licenses/by-nd/4.0 This is an open access article distributed under the Creative Commons Attribution-NoDerivatives License 4.0, which allows for redistribution, commercial and non-commercial, as long as it is passed along unchanged and in whole, with credit to the author. http://creativecommons.org/licenses/by-nd/4.0 |
spellingShingle | Research Article Xu, Hongtao Lin, Weiwei Jin, Guorong Xin, Dongmei Zhang, Jian Kang, Kai Dong, Jiangtao Gao, Shijun Chen, Baicheng Graft choice for anatomic anterior cruciate ligament reconstruction: The comparison between thin autograft and thick hybrid graft. An observational study |
title | Graft choice for anatomic anterior cruciate ligament reconstruction: The comparison between thin autograft and thick hybrid graft. An observational study |
title_full | Graft choice for anatomic anterior cruciate ligament reconstruction: The comparison between thin autograft and thick hybrid graft. An observational study |
title_fullStr | Graft choice for anatomic anterior cruciate ligament reconstruction: The comparison between thin autograft and thick hybrid graft. An observational study |
title_full_unstemmed | Graft choice for anatomic anterior cruciate ligament reconstruction: The comparison between thin autograft and thick hybrid graft. An observational study |
title_short | Graft choice for anatomic anterior cruciate ligament reconstruction: The comparison between thin autograft and thick hybrid graft. An observational study |
title_sort | graft choice for anatomic anterior cruciate ligament reconstruction: the comparison between thin autograft and thick hybrid graft. an observational study |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6078656/ https://www.ncbi.nlm.nih.gov/pubmed/30045294 http://dx.doi.org/10.1097/MD.0000000000011597 |
work_keys_str_mv | AT xuhongtao graftchoiceforanatomicanteriorcruciateligamentreconstructionthecomparisonbetweenthinautograftandthickhybridgraftanobservationalstudy AT linweiwei graftchoiceforanatomicanteriorcruciateligamentreconstructionthecomparisonbetweenthinautograftandthickhybridgraftanobservationalstudy AT jinguorong graftchoiceforanatomicanteriorcruciateligamentreconstructionthecomparisonbetweenthinautograftandthickhybridgraftanobservationalstudy AT xindongmei graftchoiceforanatomicanteriorcruciateligamentreconstructionthecomparisonbetweenthinautograftandthickhybridgraftanobservationalstudy AT zhangjian graftchoiceforanatomicanteriorcruciateligamentreconstructionthecomparisonbetweenthinautograftandthickhybridgraftanobservationalstudy AT kangkai graftchoiceforanatomicanteriorcruciateligamentreconstructionthecomparisonbetweenthinautograftandthickhybridgraftanobservationalstudy AT dongjiangtao graftchoiceforanatomicanteriorcruciateligamentreconstructionthecomparisonbetweenthinautograftandthickhybridgraftanobservationalstudy AT gaoshijun graftchoiceforanatomicanteriorcruciateligamentreconstructionthecomparisonbetweenthinautograftandthickhybridgraftanobservationalstudy AT chenbaicheng graftchoiceforanatomicanteriorcruciateligamentreconstructionthecomparisonbetweenthinautograftandthickhybridgraftanobservationalstudy |