Cargando…

Knowledge-based iterative model reconstruction: Comparative image quality with low tube voltage cerebral CT angiography

The aim of this study was to compare image quality of low tube voltage cerebral computed tomography angiography (CTA) reconstructed with knowledge-based iterative model reconstruction (IMR), filtered back projection (FBP), and hybrid iterative reconstruction (HIR). A total of 101 patients with suspe...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Xinrui, Zhu, Chengcheng, Li, Jing, Degnan, Andrew J., Jiang, Tao, Lu, Jianping
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer Health 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6078758/
https://www.ncbi.nlm.nih.gov/pubmed/30045274
http://dx.doi.org/10.1097/MD.0000000000011514
_version_ 1783345146608222208
author Wang, Xinrui
Zhu, Chengcheng
Li, Jing
Degnan, Andrew J.
Jiang, Tao
Lu, Jianping
author_facet Wang, Xinrui
Zhu, Chengcheng
Li, Jing
Degnan, Andrew J.
Jiang, Tao
Lu, Jianping
author_sort Wang, Xinrui
collection PubMed
description The aim of this study was to compare image quality of low tube voltage cerebral computed tomography angiography (CTA) reconstructed with knowledge-based iterative model reconstruction (IMR), filtered back projection (FBP), and hybrid iterative reconstruction (HIR). A total of 101 patients with suspected cerebrovascular diseases were enrolled and randomized into 2 groups, 100 kVp tube voltage (n = 53) and reduced tube voltage (80 kVp) (n = 48). Computed tomography data were reconstructed with IMR, FBP, and HIR algorithms. The image noise, vascular attenuation, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were measured and calculated. Two blinded radiologists independently evaluated image quality based on diagnostic confidence on a 3-point scale. Quantitative and qualitative assessments were compared between different groups and reconstruction subgroups. Vascular attenuation was higher in the reduced tube voltage group than in 100-kVp tube voltage group, but showed no significant difference within each group. In both groups, the image noise, vascular SNR, and CNR were significantly improved by IMR as compared with FBP and HIR. Inter-group comparison indicated that IMR with reduced tube voltage showed better image quality with lower image noise and higher vascular SNR and CNR than FBP and HIR at 100 kVp, but slightly inferior to IMR at 100 kVp. IMR also yields the best qualitative image quality, and improves the diagnostic confidence of atherosclerosis and aneurysm. Compared with the standard 120-kVp protocol (1.86mSv), the radiation doses of 100 kVp (1.13mSv) and 80 kVp (0.56mSv) were 39% and 70% less, respectively. The quantitative and qualitative image quality obtained by IMR was superior to that obtained by FBP and HIR for low tube voltage cerebral CTA.
format Online
Article
Text
id pubmed-6078758
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Wolters Kluwer Health
record_format MEDLINE/PubMed
spelling pubmed-60787582018-08-13 Knowledge-based iterative model reconstruction: Comparative image quality with low tube voltage cerebral CT angiography Wang, Xinrui Zhu, Chengcheng Li, Jing Degnan, Andrew J. Jiang, Tao Lu, Jianping Medicine (Baltimore) Research Article The aim of this study was to compare image quality of low tube voltage cerebral computed tomography angiography (CTA) reconstructed with knowledge-based iterative model reconstruction (IMR), filtered back projection (FBP), and hybrid iterative reconstruction (HIR). A total of 101 patients with suspected cerebrovascular diseases were enrolled and randomized into 2 groups, 100 kVp tube voltage (n = 53) and reduced tube voltage (80 kVp) (n = 48). Computed tomography data were reconstructed with IMR, FBP, and HIR algorithms. The image noise, vascular attenuation, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were measured and calculated. Two blinded radiologists independently evaluated image quality based on diagnostic confidence on a 3-point scale. Quantitative and qualitative assessments were compared between different groups and reconstruction subgroups. Vascular attenuation was higher in the reduced tube voltage group than in 100-kVp tube voltage group, but showed no significant difference within each group. In both groups, the image noise, vascular SNR, and CNR were significantly improved by IMR as compared with FBP and HIR. Inter-group comparison indicated that IMR with reduced tube voltage showed better image quality with lower image noise and higher vascular SNR and CNR than FBP and HIR at 100 kVp, but slightly inferior to IMR at 100 kVp. IMR also yields the best qualitative image quality, and improves the diagnostic confidence of atherosclerosis and aneurysm. Compared with the standard 120-kVp protocol (1.86mSv), the radiation doses of 100 kVp (1.13mSv) and 80 kVp (0.56mSv) were 39% and 70% less, respectively. The quantitative and qualitative image quality obtained by IMR was superior to that obtained by FBP and HIR for low tube voltage cerebral CTA. Wolters Kluwer Health 2018-07-27 /pmc/articles/PMC6078758/ /pubmed/30045274 http://dx.doi.org/10.1097/MD.0000000000011514 Text en Copyright © 2018 the Author(s). Published by Wolters Kluwer Health, Inc. http://creativecommons.org/licenses/by-nd/4.0 This is an open access article distributed under the Creative Commons Attribution-NoDerivatives License 4.0, which allows for redistribution, commercial and non-commercial, as long as it is passed along unchanged and in whole, with credit to the author. http://creativecommons.org/licenses/by-nd/4.0
spellingShingle Research Article
Wang, Xinrui
Zhu, Chengcheng
Li, Jing
Degnan, Andrew J.
Jiang, Tao
Lu, Jianping
Knowledge-based iterative model reconstruction: Comparative image quality with low tube voltage cerebral CT angiography
title Knowledge-based iterative model reconstruction: Comparative image quality with low tube voltage cerebral CT angiography
title_full Knowledge-based iterative model reconstruction: Comparative image quality with low tube voltage cerebral CT angiography
title_fullStr Knowledge-based iterative model reconstruction: Comparative image quality with low tube voltage cerebral CT angiography
title_full_unstemmed Knowledge-based iterative model reconstruction: Comparative image quality with low tube voltage cerebral CT angiography
title_short Knowledge-based iterative model reconstruction: Comparative image quality with low tube voltage cerebral CT angiography
title_sort knowledge-based iterative model reconstruction: comparative image quality with low tube voltage cerebral ct angiography
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6078758/
https://www.ncbi.nlm.nih.gov/pubmed/30045274
http://dx.doi.org/10.1097/MD.0000000000011514
work_keys_str_mv AT wangxinrui knowledgebasediterativemodelreconstructioncomparativeimagequalitywithlowtubevoltagecerebralctangiography
AT zhuchengcheng knowledgebasediterativemodelreconstructioncomparativeimagequalitywithlowtubevoltagecerebralctangiography
AT lijing knowledgebasediterativemodelreconstructioncomparativeimagequalitywithlowtubevoltagecerebralctangiography
AT degnanandrewj knowledgebasediterativemodelreconstructioncomparativeimagequalitywithlowtubevoltagecerebralctangiography
AT jiangtao knowledgebasediterativemodelreconstructioncomparativeimagequalitywithlowtubevoltagecerebralctangiography
AT lujianping knowledgebasediterativemodelreconstructioncomparativeimagequalitywithlowtubevoltagecerebralctangiography