INTRODUCTION: Minimally invasive oblique lumbar interbody fusion is one of the novel lateral lumbar interbody fusion techniques for which the successful early results have been reported. However, new complications were increasingly reported from ongoing studies. CASE PRESENTATION: We report a case o...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6079598/ https://www.ncbi.nlm.nih.gov/pubmed/30123602 http://dx.doi.org/10.1155/2018/9142074 |
_version_ | 1783345310535254016 |
---|---|
author | Kraiwattanapong, Chaiwat Arnuntasupakul, Vanlapa Kantawan, Rungthiwa Keorochana, Gun Lertudomphonwanit, Thamrong Sirijaturaporn, Pakkanut Thonginta, Methawut |
author_facet | Kraiwattanapong, Chaiwat Arnuntasupakul, Vanlapa Kantawan, Rungthiwa Keorochana, Gun Lertudomphonwanit, Thamrong Sirijaturaporn, Pakkanut Thonginta, Methawut |
author_sort | Kraiwattanapong, Chaiwat |
collection | PubMed |
description | INTRODUCTION: Minimally invasive oblique lumbar interbody fusion is one of the novel lateral lumbar interbody fusion techniques for which the successful early results have been reported. However, new complications were increasingly reported from ongoing studies. CASE PRESENTATION: We report a case of an unusual complication of minimally invasive oblique lumbar interbody fusion associated with contralateral nerve root compression due to deep and posterior position of polyetheretherketone cage and discussion of the operating technique for repositioning polyetheretherketone cage. CONCLUSION: Malposition of polyetheretherketone cage can cause contralateral nerve root compression and neurological complication. The surgical technique to proper pull the polyetheretherketone cage back into the acceptable position should be considered and well prepared. |
format | Online Article Text |
id | pubmed-6079598 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-60795982018-08-19 Malposition of Cage in Minimally Invasive Oblique Lumbar Interbody Fusion Kraiwattanapong, Chaiwat Arnuntasupakul, Vanlapa Kantawan, Rungthiwa Keorochana, Gun Lertudomphonwanit, Thamrong Sirijaturaporn, Pakkanut Thonginta, Methawut Case Rep Orthop Case Report INTRODUCTION: Minimally invasive oblique lumbar interbody fusion is one of the novel lateral lumbar interbody fusion techniques for which the successful early results have been reported. However, new complications were increasingly reported from ongoing studies. CASE PRESENTATION: We report a case of an unusual complication of minimally invasive oblique lumbar interbody fusion associated with contralateral nerve root compression due to deep and posterior position of polyetheretherketone cage and discussion of the operating technique for repositioning polyetheretherketone cage. CONCLUSION: Malposition of polyetheretherketone cage can cause contralateral nerve root compression and neurological complication. The surgical technique to proper pull the polyetheretherketone cage back into the acceptable position should be considered and well prepared. Hindawi 2018-07-11 /pmc/articles/PMC6079598/ /pubmed/30123602 http://dx.doi.org/10.1155/2018/9142074 Text en Copyright © 2018 Chaiwat Kraiwattanapong et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Kraiwattanapong, Chaiwat Arnuntasupakul, Vanlapa Kantawan, Rungthiwa Keorochana, Gun Lertudomphonwanit, Thamrong Sirijaturaporn, Pakkanut Thonginta, Methawut Malposition of Cage in Minimally Invasive Oblique Lumbar Interbody Fusion |
title | Malposition of Cage in Minimally Invasive Oblique Lumbar Interbody Fusion |
title_full | Malposition of Cage in Minimally Invasive Oblique Lumbar Interbody Fusion |
title_fullStr | Malposition of Cage in Minimally Invasive Oblique Lumbar Interbody Fusion |
title_full_unstemmed | Malposition of Cage in Minimally Invasive Oblique Lumbar Interbody Fusion |
title_short | Malposition of Cage in Minimally Invasive Oblique Lumbar Interbody Fusion |
title_sort | malposition of cage in minimally invasive oblique lumbar interbody fusion |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6079598/ https://www.ncbi.nlm.nih.gov/pubmed/30123602 http://dx.doi.org/10.1155/2018/9142074 |
work_keys_str_mv | AT kraiwattanapongchaiwat malpositionofcageinminimallyinvasiveobliquelumbarinterbodyfusion AT arnuntasupakulvanlapa malpositionofcageinminimallyinvasiveobliquelumbarinterbodyfusion AT kantawanrungthiwa malpositionofcageinminimallyinvasiveobliquelumbarinterbodyfusion AT keorochanagun malpositionofcageinminimallyinvasiveobliquelumbarinterbodyfusion AT lertudomphonwanitthamrong malpositionofcageinminimallyinvasiveobliquelumbarinterbodyfusion AT sirijaturapornpakkanut malpositionofcageinminimallyinvasiveobliquelumbarinterbodyfusion AT thongintamethawut malpositionofcageinminimallyinvasiveobliquelumbarinterbodyfusion |