Cargando…

Malposition of Cage in Minimally Invasive Oblique Lumbar Interbody Fusion

INTRODUCTION: Minimally invasive oblique lumbar interbody fusion is one of the novel lateral lumbar interbody fusion techniques for which the successful early results have been reported. However, new complications were increasingly reported from ongoing studies. CASE PRESENTATION: We report a case o...

Descripción completa

Detalles Bibliográficos
Autores principales: Kraiwattanapong, Chaiwat, Arnuntasupakul, Vanlapa, Kantawan, Rungthiwa, Keorochana, Gun, Lertudomphonwanit, Thamrong, Sirijaturaporn, Pakkanut, Thonginta, Methawut
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6079598/
https://www.ncbi.nlm.nih.gov/pubmed/30123602
http://dx.doi.org/10.1155/2018/9142074
_version_ 1783345310535254016
author Kraiwattanapong, Chaiwat
Arnuntasupakul, Vanlapa
Kantawan, Rungthiwa
Keorochana, Gun
Lertudomphonwanit, Thamrong
Sirijaturaporn, Pakkanut
Thonginta, Methawut
author_facet Kraiwattanapong, Chaiwat
Arnuntasupakul, Vanlapa
Kantawan, Rungthiwa
Keorochana, Gun
Lertudomphonwanit, Thamrong
Sirijaturaporn, Pakkanut
Thonginta, Methawut
author_sort Kraiwattanapong, Chaiwat
collection PubMed
description INTRODUCTION: Minimally invasive oblique lumbar interbody fusion is one of the novel lateral lumbar interbody fusion techniques for which the successful early results have been reported. However, new complications were increasingly reported from ongoing studies. CASE PRESENTATION: We report a case of an unusual complication of minimally invasive oblique lumbar interbody fusion associated with contralateral nerve root compression due to deep and posterior position of polyetheretherketone cage and discussion of the operating technique for repositioning polyetheretherketone cage. CONCLUSION: Malposition of polyetheretherketone cage can cause contralateral nerve root compression and neurological complication. The surgical technique to proper pull the polyetheretherketone cage back into the acceptable position should be considered and well prepared.
format Online
Article
Text
id pubmed-6079598
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-60795982018-08-19 Malposition of Cage in Minimally Invasive Oblique Lumbar Interbody Fusion Kraiwattanapong, Chaiwat Arnuntasupakul, Vanlapa Kantawan, Rungthiwa Keorochana, Gun Lertudomphonwanit, Thamrong Sirijaturaporn, Pakkanut Thonginta, Methawut Case Rep Orthop Case Report INTRODUCTION: Minimally invasive oblique lumbar interbody fusion is one of the novel lateral lumbar interbody fusion techniques for which the successful early results have been reported. However, new complications were increasingly reported from ongoing studies. CASE PRESENTATION: We report a case of an unusual complication of minimally invasive oblique lumbar interbody fusion associated with contralateral nerve root compression due to deep and posterior position of polyetheretherketone cage and discussion of the operating technique for repositioning polyetheretherketone cage. CONCLUSION: Malposition of polyetheretherketone cage can cause contralateral nerve root compression and neurological complication. The surgical technique to proper pull the polyetheretherketone cage back into the acceptable position should be considered and well prepared. Hindawi 2018-07-11 /pmc/articles/PMC6079598/ /pubmed/30123602 http://dx.doi.org/10.1155/2018/9142074 Text en Copyright © 2018 Chaiwat Kraiwattanapong et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Kraiwattanapong, Chaiwat
Arnuntasupakul, Vanlapa
Kantawan, Rungthiwa
Keorochana, Gun
Lertudomphonwanit, Thamrong
Sirijaturaporn, Pakkanut
Thonginta, Methawut
Malposition of Cage in Minimally Invasive Oblique Lumbar Interbody Fusion
title Malposition of Cage in Minimally Invasive Oblique Lumbar Interbody Fusion
title_full Malposition of Cage in Minimally Invasive Oblique Lumbar Interbody Fusion
title_fullStr Malposition of Cage in Minimally Invasive Oblique Lumbar Interbody Fusion
title_full_unstemmed Malposition of Cage in Minimally Invasive Oblique Lumbar Interbody Fusion
title_short Malposition of Cage in Minimally Invasive Oblique Lumbar Interbody Fusion
title_sort malposition of cage in minimally invasive oblique lumbar interbody fusion
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6079598/
https://www.ncbi.nlm.nih.gov/pubmed/30123602
http://dx.doi.org/10.1155/2018/9142074
work_keys_str_mv AT kraiwattanapongchaiwat malpositionofcageinminimallyinvasiveobliquelumbarinterbodyfusion
AT arnuntasupakulvanlapa malpositionofcageinminimallyinvasiveobliquelumbarinterbodyfusion
AT kantawanrungthiwa malpositionofcageinminimallyinvasiveobliquelumbarinterbodyfusion
AT keorochanagun malpositionofcageinminimallyinvasiveobliquelumbarinterbodyfusion
AT lertudomphonwanitthamrong malpositionofcageinminimallyinvasiveobliquelumbarinterbodyfusion
AT sirijaturapornpakkanut malpositionofcageinminimallyinvasiveobliquelumbarinterbodyfusion
AT thongintamethawut malpositionofcageinminimallyinvasiveobliquelumbarinterbodyfusion