Cargando…

A Nonliquid Crystal Display Screen Computer for Treatment of Photosensitivity and Computer Screen Intolerance in Post-Concussion Syndrome

Liquid crystal display (LCD) screens refresh at a rate of 60 times per second, which can be perceived by concussed individuals who have photosensitivity, leading to computer intolerance. A non-LCD computer screen that refreshes at a much lower rate could relieve this photosensitivity and computer sc...

Descripción completa

Detalles Bibliográficos
Autores principales: Mansur, Ann, Hauer, Tyler M., Hussain, Mohammed Wasif, Alatwi, Mohammed K., Tarazi, Apameh, Khodadadi, Mozhgan, Tator, Charles H.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Mary Ann Liebert, Inc. 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6079648/
https://www.ncbi.nlm.nih.gov/pubmed/30074876
http://dx.doi.org/10.1089/neu.2017.5539
_version_ 1783345321292595200
author Mansur, Ann
Hauer, Tyler M.
Hussain, Mohammed Wasif
Alatwi, Mohammed K.
Tarazi, Apameh
Khodadadi, Mozhgan
Tator, Charles H.
author_facet Mansur, Ann
Hauer, Tyler M.
Hussain, Mohammed Wasif
Alatwi, Mohammed K.
Tarazi, Apameh
Khodadadi, Mozhgan
Tator, Charles H.
author_sort Mansur, Ann
collection PubMed
description Liquid crystal display (LCD) screens refresh at a rate of 60 times per second, which can be perceived by concussed individuals who have photosensitivity, leading to computer intolerance. A non-LCD computer screen that refreshes at a much lower rate could relieve this photosensitivity and computer screen intolerance in patients with post-concussion syndrome (PCS). Twenty-nine patients with PCS, computer intolerance, and photosensitivity performed a reading task for a maximum of 30 min, with an LCD computer or a non-LCD device, and were given a comprehension test after completion of the reading task. The Sport Concussion Assessment Tool 3 was administered before and after each reading task. Symptom scores, amount of time spent reading, and performance on the comprehension tests were compared between the two devices. Patients also completed a self-report questionnaire of their subjective experience. The LCD screen computer produced significantly greater symptom exacerbation (median difference = 5, W = 315, p < 0.01) and a greater number of symptoms (median difference = 1, W = 148, p < 0.01) than the non-LCD screens. The non-LCD screen resulted in a longer symptom-free reading time (median = 48 sec, W = 147, p < 0.01), but not a greater number of words read (median = 281, W = 148, p = 0.098). Females were more likely to have greater symptom exacerbation with the LCD screen (U = 14.0, p < 0.01). No significant difference was found in performance on the comprehension test. Subjective reports showed that the non-LCD experience was more favorable, and most patients stated they would recommend this device for other patients with PCS. This study is the first to show the clinical utility of non-LCD screen computers in the management of photosensitivity and computer screen intolerance in patients with PCS. The non-LCD screen computer has the potential to facilitate return-to-work or return-to-school in concussed individuals.
format Online
Article
Text
id pubmed-6079648
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Mary Ann Liebert, Inc.
record_format MEDLINE/PubMed
spelling pubmed-60796482018-08-15 A Nonliquid Crystal Display Screen Computer for Treatment of Photosensitivity and Computer Screen Intolerance in Post-Concussion Syndrome Mansur, Ann Hauer, Tyler M. Hussain, Mohammed Wasif Alatwi, Mohammed K. Tarazi, Apameh Khodadadi, Mozhgan Tator, Charles H. J Neurotrauma Original Articles Liquid crystal display (LCD) screens refresh at a rate of 60 times per second, which can be perceived by concussed individuals who have photosensitivity, leading to computer intolerance. A non-LCD computer screen that refreshes at a much lower rate could relieve this photosensitivity and computer screen intolerance in patients with post-concussion syndrome (PCS). Twenty-nine patients with PCS, computer intolerance, and photosensitivity performed a reading task for a maximum of 30 min, with an LCD computer or a non-LCD device, and were given a comprehension test after completion of the reading task. The Sport Concussion Assessment Tool 3 was administered before and after each reading task. Symptom scores, amount of time spent reading, and performance on the comprehension tests were compared between the two devices. Patients also completed a self-report questionnaire of their subjective experience. The LCD screen computer produced significantly greater symptom exacerbation (median difference = 5, W = 315, p < 0.01) and a greater number of symptoms (median difference = 1, W = 148, p < 0.01) than the non-LCD screens. The non-LCD screen resulted in a longer symptom-free reading time (median = 48 sec, W = 147, p < 0.01), but not a greater number of words read (median = 281, W = 148, p = 0.098). Females were more likely to have greater symptom exacerbation with the LCD screen (U = 14.0, p < 0.01). No significant difference was found in performance on the comprehension test. Subjective reports showed that the non-LCD experience was more favorable, and most patients stated they would recommend this device for other patients with PCS. This study is the first to show the clinical utility of non-LCD screen computers in the management of photosensitivity and computer screen intolerance in patients with PCS. The non-LCD screen computer has the potential to facilitate return-to-work or return-to-school in concussed individuals. Mary Ann Liebert, Inc. 2018-08-15 2018-08-15 /pmc/articles/PMC6079648/ /pubmed/30074876 http://dx.doi.org/10.1089/neu.2017.5539 Text en © Ann Mansur et al., 2018; Published by Mary Ann Liebert, Inc. This Open Access article is distributed under the terms of the Creative Commons Attribution Noncommercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited.
spellingShingle Original Articles
Mansur, Ann
Hauer, Tyler M.
Hussain, Mohammed Wasif
Alatwi, Mohammed K.
Tarazi, Apameh
Khodadadi, Mozhgan
Tator, Charles H.
A Nonliquid Crystal Display Screen Computer for Treatment of Photosensitivity and Computer Screen Intolerance in Post-Concussion Syndrome
title A Nonliquid Crystal Display Screen Computer for Treatment of Photosensitivity and Computer Screen Intolerance in Post-Concussion Syndrome
title_full A Nonliquid Crystal Display Screen Computer for Treatment of Photosensitivity and Computer Screen Intolerance in Post-Concussion Syndrome
title_fullStr A Nonliquid Crystal Display Screen Computer for Treatment of Photosensitivity and Computer Screen Intolerance in Post-Concussion Syndrome
title_full_unstemmed A Nonliquid Crystal Display Screen Computer for Treatment of Photosensitivity and Computer Screen Intolerance in Post-Concussion Syndrome
title_short A Nonliquid Crystal Display Screen Computer for Treatment of Photosensitivity and Computer Screen Intolerance in Post-Concussion Syndrome
title_sort nonliquid crystal display screen computer for treatment of photosensitivity and computer screen intolerance in post-concussion syndrome
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6079648/
https://www.ncbi.nlm.nih.gov/pubmed/30074876
http://dx.doi.org/10.1089/neu.2017.5539
work_keys_str_mv AT mansurann anonliquidcrystaldisplayscreencomputerfortreatmentofphotosensitivityandcomputerscreenintoleranceinpostconcussionsyndrome
AT hauertylerm anonliquidcrystaldisplayscreencomputerfortreatmentofphotosensitivityandcomputerscreenintoleranceinpostconcussionsyndrome
AT hussainmohammedwasif anonliquidcrystaldisplayscreencomputerfortreatmentofphotosensitivityandcomputerscreenintoleranceinpostconcussionsyndrome
AT alatwimohammedk anonliquidcrystaldisplayscreencomputerfortreatmentofphotosensitivityandcomputerscreenintoleranceinpostconcussionsyndrome
AT taraziapameh anonliquidcrystaldisplayscreencomputerfortreatmentofphotosensitivityandcomputerscreenintoleranceinpostconcussionsyndrome
AT khodadadimozhgan anonliquidcrystaldisplayscreencomputerfortreatmentofphotosensitivityandcomputerscreenintoleranceinpostconcussionsyndrome
AT tatorcharlesh anonliquidcrystaldisplayscreencomputerfortreatmentofphotosensitivityandcomputerscreenintoleranceinpostconcussionsyndrome
AT mansurann nonliquidcrystaldisplayscreencomputerfortreatmentofphotosensitivityandcomputerscreenintoleranceinpostconcussionsyndrome
AT hauertylerm nonliquidcrystaldisplayscreencomputerfortreatmentofphotosensitivityandcomputerscreenintoleranceinpostconcussionsyndrome
AT hussainmohammedwasif nonliquidcrystaldisplayscreencomputerfortreatmentofphotosensitivityandcomputerscreenintoleranceinpostconcussionsyndrome
AT alatwimohammedk nonliquidcrystaldisplayscreencomputerfortreatmentofphotosensitivityandcomputerscreenintoleranceinpostconcussionsyndrome
AT taraziapameh nonliquidcrystaldisplayscreencomputerfortreatmentofphotosensitivityandcomputerscreenintoleranceinpostconcussionsyndrome
AT khodadadimozhgan nonliquidcrystaldisplayscreencomputerfortreatmentofphotosensitivityandcomputerscreenintoleranceinpostconcussionsyndrome
AT tatorcharlesh nonliquidcrystaldisplayscreencomputerfortreatmentofphotosensitivityandcomputerscreenintoleranceinpostconcussionsyndrome