Cargando…
Drug-Eluting Balloons versus Second-Generation Drug-Eluting Stents for Treating In-Stent Restenosis in Coronary Heart Disease after PCI: A Meta-Analysis
BACKGROUND: In-stent restenosis (ISR) remains a common problem following percutaneous coronary intervention (PCI). However, the best treatment strategy remains uncertain. There is some controversy over the efficacy of drug-eluting balloons (DEBs) and second-generation drug-eluting stents (DESs) for...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6081601/ https://www.ncbi.nlm.nih.gov/pubmed/30155288 http://dx.doi.org/10.1155/2018/7658145 |
_version_ | 1783345682952749056 |
---|---|
author | Xiu, Wen-Juan Yang, Hai-Tao Zheng, Ying-Ying Ma, Yi-Tong Xie, Xiang |
author_facet | Xiu, Wen-Juan Yang, Hai-Tao Zheng, Ying-Ying Ma, Yi-Tong Xie, Xiang |
author_sort | Xiu, Wen-Juan |
collection | PubMed |
description | BACKGROUND: In-stent restenosis (ISR) remains a common problem following percutaneous coronary intervention (PCI). However, the best treatment strategy remains uncertain. There is some controversy over the efficacy of drug-eluting balloons (DEBs) and second-generation drug-eluting stents (DESs) for treating ISR. METHODS: A meta-analysis was used to compare the efficacy of the DEB and second-generation DES in the treatment of ISR. The primary endpoint is the incidence of target lesion revascularization (TLR). The secondary endpoint is the occurrence of target vessel revascularization (TVR), myocardial infarction (MI), all-cause death (ACM), cardiac death (CD), major adverse cardiac events (MACEs), minimum luminal diameter (MLD), late luminal loss (LLL), binary restenosis (BR), and percent diameter stenosis (DS%). RESULTS: A total of 12 studies (4 randomized controlled trials and 8 observational studies) including 2020 patients with a follow-up of 6–25 months were included in the present study. There was a significant difference in the MLD between the two groups during follow-up (P=0.007, RR = 0.23, and 95% CI: 0.06–0.4 mm). There was no significant difference in LLL, BR, or DS% and the overall incidence of MACEs between the two groups. Subgroup analysis showed no significant difference in the incidence of primary and secondary endpoints when considering RCTs or observational studies only. CONCLUSIONS: The efficacy of the DEB and second-generation DES in the treatment of ISR is comparable. However, our results need further verification through multicenter randomized controlled trials. |
format | Online Article Text |
id | pubmed-6081601 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-60816012018-08-28 Drug-Eluting Balloons versus Second-Generation Drug-Eluting Stents for Treating In-Stent Restenosis in Coronary Heart Disease after PCI: A Meta-Analysis Xiu, Wen-Juan Yang, Hai-Tao Zheng, Ying-Ying Ma, Yi-Tong Xie, Xiang Cardiol Res Pract Review Article BACKGROUND: In-stent restenosis (ISR) remains a common problem following percutaneous coronary intervention (PCI). However, the best treatment strategy remains uncertain. There is some controversy over the efficacy of drug-eluting balloons (DEBs) and second-generation drug-eluting stents (DESs) for treating ISR. METHODS: A meta-analysis was used to compare the efficacy of the DEB and second-generation DES in the treatment of ISR. The primary endpoint is the incidence of target lesion revascularization (TLR). The secondary endpoint is the occurrence of target vessel revascularization (TVR), myocardial infarction (MI), all-cause death (ACM), cardiac death (CD), major adverse cardiac events (MACEs), minimum luminal diameter (MLD), late luminal loss (LLL), binary restenosis (BR), and percent diameter stenosis (DS%). RESULTS: A total of 12 studies (4 randomized controlled trials and 8 observational studies) including 2020 patients with a follow-up of 6–25 months were included in the present study. There was a significant difference in the MLD between the two groups during follow-up (P=0.007, RR = 0.23, and 95% CI: 0.06–0.4 mm). There was no significant difference in LLL, BR, or DS% and the overall incidence of MACEs between the two groups. Subgroup analysis showed no significant difference in the incidence of primary and secondary endpoints when considering RCTs or observational studies only. CONCLUSIONS: The efficacy of the DEB and second-generation DES in the treatment of ISR is comparable. However, our results need further verification through multicenter randomized controlled trials. Hindawi 2018-07-24 /pmc/articles/PMC6081601/ /pubmed/30155288 http://dx.doi.org/10.1155/2018/7658145 Text en Copyright © 2018 Wen-Juan Xiu et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Review Article Xiu, Wen-Juan Yang, Hai-Tao Zheng, Ying-Ying Ma, Yi-Tong Xie, Xiang Drug-Eluting Balloons versus Second-Generation Drug-Eluting Stents for Treating In-Stent Restenosis in Coronary Heart Disease after PCI: A Meta-Analysis |
title | Drug-Eluting Balloons versus Second-Generation Drug-Eluting Stents for Treating In-Stent Restenosis in Coronary Heart Disease after PCI: A Meta-Analysis |
title_full | Drug-Eluting Balloons versus Second-Generation Drug-Eluting Stents for Treating In-Stent Restenosis in Coronary Heart Disease after PCI: A Meta-Analysis |
title_fullStr | Drug-Eluting Balloons versus Second-Generation Drug-Eluting Stents for Treating In-Stent Restenosis in Coronary Heart Disease after PCI: A Meta-Analysis |
title_full_unstemmed | Drug-Eluting Balloons versus Second-Generation Drug-Eluting Stents for Treating In-Stent Restenosis in Coronary Heart Disease after PCI: A Meta-Analysis |
title_short | Drug-Eluting Balloons versus Second-Generation Drug-Eluting Stents for Treating In-Stent Restenosis in Coronary Heart Disease after PCI: A Meta-Analysis |
title_sort | drug-eluting balloons versus second-generation drug-eluting stents for treating in-stent restenosis in coronary heart disease after pci: a meta-analysis |
topic | Review Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6081601/ https://www.ncbi.nlm.nih.gov/pubmed/30155288 http://dx.doi.org/10.1155/2018/7658145 |
work_keys_str_mv | AT xiuwenjuan drugelutingballoonsversussecondgenerationdrugelutingstentsfortreatinginstentrestenosisincoronaryheartdiseaseafterpciametaanalysis AT yanghaitao drugelutingballoonsversussecondgenerationdrugelutingstentsfortreatinginstentrestenosisincoronaryheartdiseaseafterpciametaanalysis AT zhengyingying drugelutingballoonsversussecondgenerationdrugelutingstentsfortreatinginstentrestenosisincoronaryheartdiseaseafterpciametaanalysis AT mayitong drugelutingballoonsversussecondgenerationdrugelutingstentsfortreatinginstentrestenosisincoronaryheartdiseaseafterpciametaanalysis AT xiexiang drugelutingballoonsversussecondgenerationdrugelutingstentsfortreatinginstentrestenosisincoronaryheartdiseaseafterpciametaanalysis |