Cargando…

Fabrication of Magnetically Actuated Fluidic Drug Delivery Device Using Polyvinyl Chloride Adhesive Stencils

In this paper, a polydimethylsiloxane (PDMS) fabrication method is introduced. It eliminates the need for conventional fabrication methods, such as photolithography and etching. Only a series of oxygen plasma treatments, silanization, and polyvinyl chloride (PVC) adhesive stencils were used to devel...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Hyun, Seo, Jong-mo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6082295/
https://www.ncbi.nlm.nih.gov/pubmed/30424291
http://dx.doi.org/10.3390/mi9070358
_version_ 1783345785719488512
author Kim, Hyun
Seo, Jong-mo
author_facet Kim, Hyun
Seo, Jong-mo
author_sort Kim, Hyun
collection PubMed
description In this paper, a polydimethylsiloxane (PDMS) fabrication method is introduced. It eliminates the need for conventional fabrication methods, such as photolithography and etching. Only a series of oxygen plasma treatments, silanization, and polyvinyl chloride (PVC) adhesive stencils were used to develop multi-layer designs. The fabrication method was applied to fabricate a PDMS-based drug delivery device with an actively controllable, magnetically actuated valve. Above all, this fabrication method eliminated the use of a power-consuming pump. Fluidic substances were injected into the circular shaped primary chamber through a syringe. A secondary chamber, similar to the primary chamber’s structure but with a smaller radius and thinner membrane, was connected via a microchannel to regulate the amount released. When actuated with a permanent magnet for one second, the volume in the secondary chamber first depletes. As the magnet is removed, the valve closes. Subsequently, the primary chamber replenishes the secondary chamber. This process can be repeated until the primary chamber reaches a saturation state that can no longer inflate the secondary chamber. The device could release a few microliters per actuation. Various combinations of size and thickness of primary, and secondary chambers can realize release rate of desired amount.
format Online
Article
Text
id pubmed-6082295
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-60822952018-11-01 Fabrication of Magnetically Actuated Fluidic Drug Delivery Device Using Polyvinyl Chloride Adhesive Stencils Kim, Hyun Seo, Jong-mo Micromachines (Basel) Article In this paper, a polydimethylsiloxane (PDMS) fabrication method is introduced. It eliminates the need for conventional fabrication methods, such as photolithography and etching. Only a series of oxygen plasma treatments, silanization, and polyvinyl chloride (PVC) adhesive stencils were used to develop multi-layer designs. The fabrication method was applied to fabricate a PDMS-based drug delivery device with an actively controllable, magnetically actuated valve. Above all, this fabrication method eliminated the use of a power-consuming pump. Fluidic substances were injected into the circular shaped primary chamber through a syringe. A secondary chamber, similar to the primary chamber’s structure but with a smaller radius and thinner membrane, was connected via a microchannel to regulate the amount released. When actuated with a permanent magnet for one second, the volume in the secondary chamber first depletes. As the magnet is removed, the valve closes. Subsequently, the primary chamber replenishes the secondary chamber. This process can be repeated until the primary chamber reaches a saturation state that can no longer inflate the secondary chamber. The device could release a few microliters per actuation. Various combinations of size and thickness of primary, and secondary chambers can realize release rate of desired amount. MDPI 2018-07-19 /pmc/articles/PMC6082295/ /pubmed/30424291 http://dx.doi.org/10.3390/mi9070358 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Kim, Hyun
Seo, Jong-mo
Fabrication of Magnetically Actuated Fluidic Drug Delivery Device Using Polyvinyl Chloride Adhesive Stencils
title Fabrication of Magnetically Actuated Fluidic Drug Delivery Device Using Polyvinyl Chloride Adhesive Stencils
title_full Fabrication of Magnetically Actuated Fluidic Drug Delivery Device Using Polyvinyl Chloride Adhesive Stencils
title_fullStr Fabrication of Magnetically Actuated Fluidic Drug Delivery Device Using Polyvinyl Chloride Adhesive Stencils
title_full_unstemmed Fabrication of Magnetically Actuated Fluidic Drug Delivery Device Using Polyvinyl Chloride Adhesive Stencils
title_short Fabrication of Magnetically Actuated Fluidic Drug Delivery Device Using Polyvinyl Chloride Adhesive Stencils
title_sort fabrication of magnetically actuated fluidic drug delivery device using polyvinyl chloride adhesive stencils
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6082295/
https://www.ncbi.nlm.nih.gov/pubmed/30424291
http://dx.doi.org/10.3390/mi9070358
work_keys_str_mv AT kimhyun fabricationofmagneticallyactuatedfluidicdrugdeliverydeviceusingpolyvinylchlorideadhesivestencils
AT seojongmo fabricationofmagneticallyactuatedfluidicdrugdeliverydeviceusingpolyvinylchlorideadhesivestencils