Cargando…

Comparative evaluation of tomographic and biometric characteristics in bilateral keratoconus patients with unilateral corneal Vogt’s striae: a contralateral eye study

PURPOSE: The aim of this study was to evaluate and compare tomographic and biometric characteristics measured by the corneal tomography and ocular biometry in bilateral keratoconus (KCN) patients with and without corneal Vogt’s striae. METHODS: Ninety-two eyes of 46 subjects with a reliable diagnosi...

Descripción completa

Detalles Bibliográficos
Autores principales: Sedaghat, Mohamad-Reza, Askarizadeh, Farshad, Narooie-Noori, Foroozan, Rakhshandadi, Tahereh, Ostadi-moghadam, Hadi, Rajabi, Sattar
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove Medical Press 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6086105/
https://www.ncbi.nlm.nih.gov/pubmed/30122891
http://dx.doi.org/10.2147/OPTH.S169266
_version_ 1783346460980412416
author Sedaghat, Mohamad-Reza
Askarizadeh, Farshad
Narooie-Noori, Foroozan
Rakhshandadi, Tahereh
Ostadi-moghadam, Hadi
Rajabi, Sattar
author_facet Sedaghat, Mohamad-Reza
Askarizadeh, Farshad
Narooie-Noori, Foroozan
Rakhshandadi, Tahereh
Ostadi-moghadam, Hadi
Rajabi, Sattar
author_sort Sedaghat, Mohamad-Reza
collection PubMed
description PURPOSE: The aim of this study was to evaluate and compare tomographic and biometric characteristics measured by the corneal tomography and ocular biometry in bilateral keratoconus (KCN) patients with and without corneal Vogt’s striae. METHODS: Ninety-two eyes of 46 subjects with a reliable diagnosis of bilateral KCN with unilateral Vogt’s striae were enrolled in this cross-sectional contralateral eye study. In addition to refraction (calculated by vectorial analysis) and visual acuity, corneal tomographic measurements were obtained by the Pentacam (Scheimpflug-based anterior segment tomography). Also, ocular biometric characteristics were evaluated using the Ocuscan(®) RxP (ultrasound biometer). The KCN eyes were categorized into two groups, including eyes with Vogt’s striae and eyes without Vogt’s striae. RESULTS: Our results showed significant differences in the sphere, cylinder, spherical equivalent, J0, corrected and uncorrected distance visual acuity, flat, steep and maximum keratometry, anterior chamber depth (ACD), and central corneal thickness (CCT) between the two groups (all P<0.001). The eyes without Vogt’s striae had a shorter ACD measured by the Pentacam and biometer. There were no differences in axial length (AL) and vitreous length (VL) between the two groups (all P>0.05). Also, there was poor agreement between the measurements of the Pentacam and ultrasound biometer for ACD in the study groups. CONCLUSION: Corneal tomographic and ocular biometric measurements showed significant differences between KCN eyes with and without Vogt’s striae except for AL and VL. These differences should be noticed in clinical evaluations and treatment of KCN patients.
format Online
Article
Text
id pubmed-6086105
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Dove Medical Press
record_format MEDLINE/PubMed
spelling pubmed-60861052018-08-17 Comparative evaluation of tomographic and biometric characteristics in bilateral keratoconus patients with unilateral corneal Vogt’s striae: a contralateral eye study Sedaghat, Mohamad-Reza Askarizadeh, Farshad Narooie-Noori, Foroozan Rakhshandadi, Tahereh Ostadi-moghadam, Hadi Rajabi, Sattar Clin Ophthalmol Original Research PURPOSE: The aim of this study was to evaluate and compare tomographic and biometric characteristics measured by the corneal tomography and ocular biometry in bilateral keratoconus (KCN) patients with and without corneal Vogt’s striae. METHODS: Ninety-two eyes of 46 subjects with a reliable diagnosis of bilateral KCN with unilateral Vogt’s striae were enrolled in this cross-sectional contralateral eye study. In addition to refraction (calculated by vectorial analysis) and visual acuity, corneal tomographic measurements were obtained by the Pentacam (Scheimpflug-based anterior segment tomography). Also, ocular biometric characteristics were evaluated using the Ocuscan(®) RxP (ultrasound biometer). The KCN eyes were categorized into two groups, including eyes with Vogt’s striae and eyes without Vogt’s striae. RESULTS: Our results showed significant differences in the sphere, cylinder, spherical equivalent, J0, corrected and uncorrected distance visual acuity, flat, steep and maximum keratometry, anterior chamber depth (ACD), and central corneal thickness (CCT) between the two groups (all P<0.001). The eyes without Vogt’s striae had a shorter ACD measured by the Pentacam and biometer. There were no differences in axial length (AL) and vitreous length (VL) between the two groups (all P>0.05). Also, there was poor agreement between the measurements of the Pentacam and ultrasound biometer for ACD in the study groups. CONCLUSION: Corneal tomographic and ocular biometric measurements showed significant differences between KCN eyes with and without Vogt’s striae except for AL and VL. These differences should be noticed in clinical evaluations and treatment of KCN patients. Dove Medical Press 2018-08-07 /pmc/articles/PMC6086105/ /pubmed/30122891 http://dx.doi.org/10.2147/OPTH.S169266 Text en © 2018 Sedaghat et al. This work is published and licensed by Dove Medical Press Limited The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed.
spellingShingle Original Research
Sedaghat, Mohamad-Reza
Askarizadeh, Farshad
Narooie-Noori, Foroozan
Rakhshandadi, Tahereh
Ostadi-moghadam, Hadi
Rajabi, Sattar
Comparative evaluation of tomographic and biometric characteristics in bilateral keratoconus patients with unilateral corneal Vogt’s striae: a contralateral eye study
title Comparative evaluation of tomographic and biometric characteristics in bilateral keratoconus patients with unilateral corneal Vogt’s striae: a contralateral eye study
title_full Comparative evaluation of tomographic and biometric characteristics in bilateral keratoconus patients with unilateral corneal Vogt’s striae: a contralateral eye study
title_fullStr Comparative evaluation of tomographic and biometric characteristics in bilateral keratoconus patients with unilateral corneal Vogt’s striae: a contralateral eye study
title_full_unstemmed Comparative evaluation of tomographic and biometric characteristics in bilateral keratoconus patients with unilateral corneal Vogt’s striae: a contralateral eye study
title_short Comparative evaluation of tomographic and biometric characteristics in bilateral keratoconus patients with unilateral corneal Vogt’s striae: a contralateral eye study
title_sort comparative evaluation of tomographic and biometric characteristics in bilateral keratoconus patients with unilateral corneal vogt’s striae: a contralateral eye study
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6086105/
https://www.ncbi.nlm.nih.gov/pubmed/30122891
http://dx.doi.org/10.2147/OPTH.S169266
work_keys_str_mv AT sedaghatmohamadreza comparativeevaluationoftomographicandbiometriccharacteristicsinbilateralkeratoconuspatientswithunilateralcornealvogtsstriaeacontralateraleyestudy
AT askarizadehfarshad comparativeevaluationoftomographicandbiometriccharacteristicsinbilateralkeratoconuspatientswithunilateralcornealvogtsstriaeacontralateraleyestudy
AT narooienooriforoozan comparativeevaluationoftomographicandbiometriccharacteristicsinbilateralkeratoconuspatientswithunilateralcornealvogtsstriaeacontralateraleyestudy
AT rakhshandaditahereh comparativeevaluationoftomographicandbiometriccharacteristicsinbilateralkeratoconuspatientswithunilateralcornealvogtsstriaeacontralateraleyestudy
AT ostadimoghadamhadi comparativeevaluationoftomographicandbiometriccharacteristicsinbilateralkeratoconuspatientswithunilateralcornealvogtsstriaeacontralateraleyestudy
AT rajabisattar comparativeevaluationoftomographicandbiometriccharacteristicsinbilateralkeratoconuspatientswithunilateralcornealvogtsstriaeacontralateraleyestudy