Cargando…
Comparative evaluation of tomographic and biometric characteristics in bilateral keratoconus patients with unilateral corneal Vogt’s striae: a contralateral eye study
PURPOSE: The aim of this study was to evaluate and compare tomographic and biometric characteristics measured by the corneal tomography and ocular biometry in bilateral keratoconus (KCN) patients with and without corneal Vogt’s striae. METHODS: Ninety-two eyes of 46 subjects with a reliable diagnosi...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove Medical Press
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6086105/ https://www.ncbi.nlm.nih.gov/pubmed/30122891 http://dx.doi.org/10.2147/OPTH.S169266 |
_version_ | 1783346460980412416 |
---|---|
author | Sedaghat, Mohamad-Reza Askarizadeh, Farshad Narooie-Noori, Foroozan Rakhshandadi, Tahereh Ostadi-moghadam, Hadi Rajabi, Sattar |
author_facet | Sedaghat, Mohamad-Reza Askarizadeh, Farshad Narooie-Noori, Foroozan Rakhshandadi, Tahereh Ostadi-moghadam, Hadi Rajabi, Sattar |
author_sort | Sedaghat, Mohamad-Reza |
collection | PubMed |
description | PURPOSE: The aim of this study was to evaluate and compare tomographic and biometric characteristics measured by the corneal tomography and ocular biometry in bilateral keratoconus (KCN) patients with and without corneal Vogt’s striae. METHODS: Ninety-two eyes of 46 subjects with a reliable diagnosis of bilateral KCN with unilateral Vogt’s striae were enrolled in this cross-sectional contralateral eye study. In addition to refraction (calculated by vectorial analysis) and visual acuity, corneal tomographic measurements were obtained by the Pentacam (Scheimpflug-based anterior segment tomography). Also, ocular biometric characteristics were evaluated using the Ocuscan(®) RxP (ultrasound biometer). The KCN eyes were categorized into two groups, including eyes with Vogt’s striae and eyes without Vogt’s striae. RESULTS: Our results showed significant differences in the sphere, cylinder, spherical equivalent, J0, corrected and uncorrected distance visual acuity, flat, steep and maximum keratometry, anterior chamber depth (ACD), and central corneal thickness (CCT) between the two groups (all P<0.001). The eyes without Vogt’s striae had a shorter ACD measured by the Pentacam and biometer. There were no differences in axial length (AL) and vitreous length (VL) between the two groups (all P>0.05). Also, there was poor agreement between the measurements of the Pentacam and ultrasound biometer for ACD in the study groups. CONCLUSION: Corneal tomographic and ocular biometric measurements showed significant differences between KCN eyes with and without Vogt’s striae except for AL and VL. These differences should be noticed in clinical evaluations and treatment of KCN patients. |
format | Online Article Text |
id | pubmed-6086105 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Dove Medical Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-60861052018-08-17 Comparative evaluation of tomographic and biometric characteristics in bilateral keratoconus patients with unilateral corneal Vogt’s striae: a contralateral eye study Sedaghat, Mohamad-Reza Askarizadeh, Farshad Narooie-Noori, Foroozan Rakhshandadi, Tahereh Ostadi-moghadam, Hadi Rajabi, Sattar Clin Ophthalmol Original Research PURPOSE: The aim of this study was to evaluate and compare tomographic and biometric characteristics measured by the corneal tomography and ocular biometry in bilateral keratoconus (KCN) patients with and without corneal Vogt’s striae. METHODS: Ninety-two eyes of 46 subjects with a reliable diagnosis of bilateral KCN with unilateral Vogt’s striae were enrolled in this cross-sectional contralateral eye study. In addition to refraction (calculated by vectorial analysis) and visual acuity, corneal tomographic measurements were obtained by the Pentacam (Scheimpflug-based anterior segment tomography). Also, ocular biometric characteristics were evaluated using the Ocuscan(®) RxP (ultrasound biometer). The KCN eyes were categorized into two groups, including eyes with Vogt’s striae and eyes without Vogt’s striae. RESULTS: Our results showed significant differences in the sphere, cylinder, spherical equivalent, J0, corrected and uncorrected distance visual acuity, flat, steep and maximum keratometry, anterior chamber depth (ACD), and central corneal thickness (CCT) between the two groups (all P<0.001). The eyes without Vogt’s striae had a shorter ACD measured by the Pentacam and biometer. There were no differences in axial length (AL) and vitreous length (VL) between the two groups (all P>0.05). Also, there was poor agreement between the measurements of the Pentacam and ultrasound biometer for ACD in the study groups. CONCLUSION: Corneal tomographic and ocular biometric measurements showed significant differences between KCN eyes with and without Vogt’s striae except for AL and VL. These differences should be noticed in clinical evaluations and treatment of KCN patients. Dove Medical Press 2018-08-07 /pmc/articles/PMC6086105/ /pubmed/30122891 http://dx.doi.org/10.2147/OPTH.S169266 Text en © 2018 Sedaghat et al. This work is published and licensed by Dove Medical Press Limited The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. |
spellingShingle | Original Research Sedaghat, Mohamad-Reza Askarizadeh, Farshad Narooie-Noori, Foroozan Rakhshandadi, Tahereh Ostadi-moghadam, Hadi Rajabi, Sattar Comparative evaluation of tomographic and biometric characteristics in bilateral keratoconus patients with unilateral corneal Vogt’s striae: a contralateral eye study |
title | Comparative evaluation of tomographic and biometric characteristics in bilateral keratoconus patients with unilateral corneal Vogt’s striae: a contralateral eye study |
title_full | Comparative evaluation of tomographic and biometric characteristics in bilateral keratoconus patients with unilateral corneal Vogt’s striae: a contralateral eye study |
title_fullStr | Comparative evaluation of tomographic and biometric characteristics in bilateral keratoconus patients with unilateral corneal Vogt’s striae: a contralateral eye study |
title_full_unstemmed | Comparative evaluation of tomographic and biometric characteristics in bilateral keratoconus patients with unilateral corneal Vogt’s striae: a contralateral eye study |
title_short | Comparative evaluation of tomographic and biometric characteristics in bilateral keratoconus patients with unilateral corneal Vogt’s striae: a contralateral eye study |
title_sort | comparative evaluation of tomographic and biometric characteristics in bilateral keratoconus patients with unilateral corneal vogt’s striae: a contralateral eye study |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6086105/ https://www.ncbi.nlm.nih.gov/pubmed/30122891 http://dx.doi.org/10.2147/OPTH.S169266 |
work_keys_str_mv | AT sedaghatmohamadreza comparativeevaluationoftomographicandbiometriccharacteristicsinbilateralkeratoconuspatientswithunilateralcornealvogtsstriaeacontralateraleyestudy AT askarizadehfarshad comparativeevaluationoftomographicandbiometriccharacteristicsinbilateralkeratoconuspatientswithunilateralcornealvogtsstriaeacontralateraleyestudy AT narooienooriforoozan comparativeevaluationoftomographicandbiometriccharacteristicsinbilateralkeratoconuspatientswithunilateralcornealvogtsstriaeacontralateraleyestudy AT rakhshandaditahereh comparativeevaluationoftomographicandbiometriccharacteristicsinbilateralkeratoconuspatientswithunilateralcornealvogtsstriaeacontralateraleyestudy AT ostadimoghadamhadi comparativeevaluationoftomographicandbiometriccharacteristicsinbilateralkeratoconuspatientswithunilateralcornealvogtsstriaeacontralateraleyestudy AT rajabisattar comparativeevaluationoftomographicandbiometriccharacteristicsinbilateralkeratoconuspatientswithunilateralcornealvogtsstriaeacontralateraleyestudy |