Cargando…

Effect of the LEGe detector collimators on K-series peaks and Compton scattering in XRF analysis using gamma rays

The effect of a low-energy germanium detector collimator with different diameters on the measurement of the X-ray fluorescence of palladium (Pd) was studied experimentally. Changes in the Pd K-series and Compton scattering peaks were measured and analysed with and without a detector collimator, wher...

Descripción completa

Detalles Bibliográficos
Autor principal: Marashdeh, Mohammad W.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6086212/
https://www.ncbi.nlm.nih.gov/pubmed/30105311
http://dx.doi.org/10.1016/j.heliyon.2018.e00724
_version_ 1783346472914255872
author Marashdeh, Mohammad W.
author_facet Marashdeh, Mohammad W.
author_sort Marashdeh, Mohammad W.
collection PubMed
description The effect of a low-energy germanium detector collimator with different diameters on the measurement of the X-ray fluorescence of palladium (Pd) was studied experimentally. Changes in the Pd K-series and Compton scattering peaks were measured and analysed with and without a detector collimator, where for the former, collimators with different diameters were used. The signal-to-noise ratio increased when a shielding collimator was used with a narrow detector collimator. The Compton dispersion and fraction dead time were reduced considerably using a detector collimator by increasing the distance from the source to the detector, and the collimator length-to-diameter ratio. The full width at half maximum (FWHM) of the Pd K(α1) and Pd K(β1) peaks decreased almost linearly with the collimator length-to-diameter ratio. The FWHM illustrated that the spectral resolution was improved when a collimator with a smaller diameter but unchanged length was used. The uncertainties at the Pd K(α1), Pd K(β1), and Compton dispersion peaks were approximately correlated linearly with the collimator length-to-diameter ratio.
format Online
Article
Text
id pubmed-6086212
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-60862122018-08-13 Effect of the LEGe detector collimators on K-series peaks and Compton scattering in XRF analysis using gamma rays Marashdeh, Mohammad W. Heliyon Article The effect of a low-energy germanium detector collimator with different diameters on the measurement of the X-ray fluorescence of palladium (Pd) was studied experimentally. Changes in the Pd K-series and Compton scattering peaks were measured and analysed with and without a detector collimator, where for the former, collimators with different diameters were used. The signal-to-noise ratio increased when a shielding collimator was used with a narrow detector collimator. The Compton dispersion and fraction dead time were reduced considerably using a detector collimator by increasing the distance from the source to the detector, and the collimator length-to-diameter ratio. The full width at half maximum (FWHM) of the Pd K(α1) and Pd K(β1) peaks decreased almost linearly with the collimator length-to-diameter ratio. The FWHM illustrated that the spectral resolution was improved when a collimator with a smaller diameter but unchanged length was used. The uncertainties at the Pd K(α1), Pd K(β1), and Compton dispersion peaks were approximately correlated linearly with the collimator length-to-diameter ratio. Elsevier 2018-08-06 /pmc/articles/PMC6086212/ /pubmed/30105311 http://dx.doi.org/10.1016/j.heliyon.2018.e00724 Text en © 2018 The Author http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Article
Marashdeh, Mohammad W.
Effect of the LEGe detector collimators on K-series peaks and Compton scattering in XRF analysis using gamma rays
title Effect of the LEGe detector collimators on K-series peaks and Compton scattering in XRF analysis using gamma rays
title_full Effect of the LEGe detector collimators on K-series peaks and Compton scattering in XRF analysis using gamma rays
title_fullStr Effect of the LEGe detector collimators on K-series peaks and Compton scattering in XRF analysis using gamma rays
title_full_unstemmed Effect of the LEGe detector collimators on K-series peaks and Compton scattering in XRF analysis using gamma rays
title_short Effect of the LEGe detector collimators on K-series peaks and Compton scattering in XRF analysis using gamma rays
title_sort effect of the lege detector collimators on k-series peaks and compton scattering in xrf analysis using gamma rays
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6086212/
https://www.ncbi.nlm.nih.gov/pubmed/30105311
http://dx.doi.org/10.1016/j.heliyon.2018.e00724
work_keys_str_mv AT marashdehmohammadw effectofthelegedetectorcollimatorsonkseriespeaksandcomptonscatteringinxrfanalysisusinggammarays