Effect of the LEGe detector collimators on K-series peaks and Compton scattering in XRF analysis using gamma rays
The effect of a low-energy germanium detector collimator with different diameters on the measurement of the X-ray fluorescence of palladium (Pd) was studied experimentally. Changes in the Pd K-series and Compton scattering peaks were measured and analysed with and without a detector collimator, wher...
Autor principal: | |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6086212/ https://www.ncbi.nlm.nih.gov/pubmed/30105311 http://dx.doi.org/10.1016/j.heliyon.2018.e00724 |
_version_ | 1783346472914255872 |
---|---|
author | Marashdeh, Mohammad W. |
author_facet | Marashdeh, Mohammad W. |
author_sort | Marashdeh, Mohammad W. |
collection | PubMed |
description | The effect of a low-energy germanium detector collimator with different diameters on the measurement of the X-ray fluorescence of palladium (Pd) was studied experimentally. Changes in the Pd K-series and Compton scattering peaks were measured and analysed with and without a detector collimator, where for the former, collimators with different diameters were used. The signal-to-noise ratio increased when a shielding collimator was used with a narrow detector collimator. The Compton dispersion and fraction dead time were reduced considerably using a detector collimator by increasing the distance from the source to the detector, and the collimator length-to-diameter ratio. The full width at half maximum (FWHM) of the Pd K(α1) and Pd K(β1) peaks decreased almost linearly with the collimator length-to-diameter ratio. The FWHM illustrated that the spectral resolution was improved when a collimator with a smaller diameter but unchanged length was used. The uncertainties at the Pd K(α1), Pd K(β1), and Compton dispersion peaks were approximately correlated linearly with the collimator length-to-diameter ratio. |
format | Online Article Text |
id | pubmed-6086212 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-60862122018-08-13 Effect of the LEGe detector collimators on K-series peaks and Compton scattering in XRF analysis using gamma rays Marashdeh, Mohammad W. Heliyon Article The effect of a low-energy germanium detector collimator with different diameters on the measurement of the X-ray fluorescence of palladium (Pd) was studied experimentally. Changes in the Pd K-series and Compton scattering peaks were measured and analysed with and without a detector collimator, where for the former, collimators with different diameters were used. The signal-to-noise ratio increased when a shielding collimator was used with a narrow detector collimator. The Compton dispersion and fraction dead time were reduced considerably using a detector collimator by increasing the distance from the source to the detector, and the collimator length-to-diameter ratio. The full width at half maximum (FWHM) of the Pd K(α1) and Pd K(β1) peaks decreased almost linearly with the collimator length-to-diameter ratio. The FWHM illustrated that the spectral resolution was improved when a collimator with a smaller diameter but unchanged length was used. The uncertainties at the Pd K(α1), Pd K(β1), and Compton dispersion peaks were approximately correlated linearly with the collimator length-to-diameter ratio. Elsevier 2018-08-06 /pmc/articles/PMC6086212/ /pubmed/30105311 http://dx.doi.org/10.1016/j.heliyon.2018.e00724 Text en © 2018 The Author http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Article Marashdeh, Mohammad W. Effect of the LEGe detector collimators on K-series peaks and Compton scattering in XRF analysis using gamma rays |
title | Effect of the LEGe detector collimators on K-series peaks and Compton scattering in XRF analysis using gamma rays |
title_full | Effect of the LEGe detector collimators on K-series peaks and Compton scattering in XRF analysis using gamma rays |
title_fullStr | Effect of the LEGe detector collimators on K-series peaks and Compton scattering in XRF analysis using gamma rays |
title_full_unstemmed | Effect of the LEGe detector collimators on K-series peaks and Compton scattering in XRF analysis using gamma rays |
title_short | Effect of the LEGe detector collimators on K-series peaks and Compton scattering in XRF analysis using gamma rays |
title_sort | effect of the lege detector collimators on k-series peaks and compton scattering in xrf analysis using gamma rays |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6086212/ https://www.ncbi.nlm.nih.gov/pubmed/30105311 http://dx.doi.org/10.1016/j.heliyon.2018.e00724 |
work_keys_str_mv | AT marashdehmohammadw effectofthelegedetectorcollimatorsonkseriespeaksandcomptonscatteringinxrfanalysisusinggammarays |