Cargando…
The diagnostic accuracy of a real-time optoelectronic device in cervical cancer screening: A PRISMA-compliant systematic review and meta-analysis
BACKGROUND: This study aimed to assess the diagnostic accuracy of a real-time optoelectronic device (TruScreen) for uterine cervical cancer screening. METHODS: On the basis of Preferred Reporting Items for Systematic Reviews and Meta-analyses (the PRISMA statement) we performed this systematic revie...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer Health
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6086506/ https://www.ncbi.nlm.nih.gov/pubmed/30024517 http://dx.doi.org/10.1097/MD.0000000000011439 |
_version_ | 1783346527851249664 |
---|---|
author | Yang, Huixia Zhang, Xinmiao Hao, Zengping |
author_facet | Yang, Huixia Zhang, Xinmiao Hao, Zengping |
author_sort | Yang, Huixia |
collection | PubMed |
description | BACKGROUND: This study aimed to assess the diagnostic accuracy of a real-time optoelectronic device (TruScreen) for uterine cervical cancer screening. METHODS: On the basis of Preferred Reporting Items for Systematic Reviews and Meta-analyses (the PRISMA statement) we performed this systematic review and meta-analysis. We searched PubMed, EMBASE, the Cochrane Library, CNKI, CBM, and WanFang Data using medical subject headings (MeSH) and text words. Title/abstract screening, full text check, data extraction, and methodological quality assessment (with the QUADAS-2 tool) were performed by 2 reviewers independently. The pooled sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), the summary receiver operator characteristic curve, and the area under the curve (AUC) were analyzed with Meta-DiSc software. Statistical heterogeneity was evaluated by Cochran's Q test and I(2), meta-regression was conducted based on patient type, and the possibility of publication bias was evaluated using Deeks funnel plot in Stata software. RESULTS: Of 293 publications, nine met our inclusion criteria. These studies included a total of 2730 patients and 567 cervical intraepithelial neoplasias. The pooled test characteristics for the TruScreen were as follows: sensitivity 76% (95% CI, 73–80%), specificity 69% (95% CI, 67%–71%), PLR 2.30 (95% CI, 1.59–3.33), and NLR 0.34 (95% CI, 0.23–0.51). The corresponding pooled DOR was 7.03 (95% CI, 3.40–14.55). The AUC was 0.7859 (Q(∗) = 0.7236). CONCLUSION: The diagnostic accuracy of the TruScreen device is moderately good. The study findings are based on Chinese studies only and could not be generalized to other populations. |
format | Online Article Text |
id | pubmed-6086506 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Wolters Kluwer Health |
record_format | MEDLINE/PubMed |
spelling | pubmed-60865062018-08-17 The diagnostic accuracy of a real-time optoelectronic device in cervical cancer screening: A PRISMA-compliant systematic review and meta-analysis Yang, Huixia Zhang, Xinmiao Hao, Zengping Medicine (Baltimore) Research Article BACKGROUND: This study aimed to assess the diagnostic accuracy of a real-time optoelectronic device (TruScreen) for uterine cervical cancer screening. METHODS: On the basis of Preferred Reporting Items for Systematic Reviews and Meta-analyses (the PRISMA statement) we performed this systematic review and meta-analysis. We searched PubMed, EMBASE, the Cochrane Library, CNKI, CBM, and WanFang Data using medical subject headings (MeSH) and text words. Title/abstract screening, full text check, data extraction, and methodological quality assessment (with the QUADAS-2 tool) were performed by 2 reviewers independently. The pooled sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), the summary receiver operator characteristic curve, and the area under the curve (AUC) were analyzed with Meta-DiSc software. Statistical heterogeneity was evaluated by Cochran's Q test and I(2), meta-regression was conducted based on patient type, and the possibility of publication bias was evaluated using Deeks funnel plot in Stata software. RESULTS: Of 293 publications, nine met our inclusion criteria. These studies included a total of 2730 patients and 567 cervical intraepithelial neoplasias. The pooled test characteristics for the TruScreen were as follows: sensitivity 76% (95% CI, 73–80%), specificity 69% (95% CI, 67%–71%), PLR 2.30 (95% CI, 1.59–3.33), and NLR 0.34 (95% CI, 0.23–0.51). The corresponding pooled DOR was 7.03 (95% CI, 3.40–14.55). The AUC was 0.7859 (Q(∗) = 0.7236). CONCLUSION: The diagnostic accuracy of the TruScreen device is moderately good. The study findings are based on Chinese studies only and could not be generalized to other populations. Wolters Kluwer Health 2018-07-20 /pmc/articles/PMC6086506/ /pubmed/30024517 http://dx.doi.org/10.1097/MD.0000000000011439 Text en Copyright © 2018 the Author(s). Published by Wolters Kluwer Health, Inc. http://creativecommons.org/licenses/by/4.0 This is an open access article distributed under the Creative Commons Attribution License 4.0 (CCBY), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. http://creativecommons.org/licenses/by/4.0 |
spellingShingle | Research Article Yang, Huixia Zhang, Xinmiao Hao, Zengping The diagnostic accuracy of a real-time optoelectronic device in cervical cancer screening: A PRISMA-compliant systematic review and meta-analysis |
title | The diagnostic accuracy of a real-time optoelectronic device in cervical cancer screening: A PRISMA-compliant systematic review and meta-analysis |
title_full | The diagnostic accuracy of a real-time optoelectronic device in cervical cancer screening: A PRISMA-compliant systematic review and meta-analysis |
title_fullStr | The diagnostic accuracy of a real-time optoelectronic device in cervical cancer screening: A PRISMA-compliant systematic review and meta-analysis |
title_full_unstemmed | The diagnostic accuracy of a real-time optoelectronic device in cervical cancer screening: A PRISMA-compliant systematic review and meta-analysis |
title_short | The diagnostic accuracy of a real-time optoelectronic device in cervical cancer screening: A PRISMA-compliant systematic review and meta-analysis |
title_sort | diagnostic accuracy of a real-time optoelectronic device in cervical cancer screening: a prisma-compliant systematic review and meta-analysis |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6086506/ https://www.ncbi.nlm.nih.gov/pubmed/30024517 http://dx.doi.org/10.1097/MD.0000000000011439 |
work_keys_str_mv | AT yanghuixia thediagnosticaccuracyofarealtimeoptoelectronicdeviceincervicalcancerscreeningaprismacompliantsystematicreviewandmetaanalysis AT zhangxinmiao thediagnosticaccuracyofarealtimeoptoelectronicdeviceincervicalcancerscreeningaprismacompliantsystematicreviewandmetaanalysis AT haozengping thediagnosticaccuracyofarealtimeoptoelectronicdeviceincervicalcancerscreeningaprismacompliantsystematicreviewandmetaanalysis AT yanghuixia diagnosticaccuracyofarealtimeoptoelectronicdeviceincervicalcancerscreeningaprismacompliantsystematicreviewandmetaanalysis AT zhangxinmiao diagnosticaccuracyofarealtimeoptoelectronicdeviceincervicalcancerscreeningaprismacompliantsystematicreviewandmetaanalysis AT haozengping diagnosticaccuracyofarealtimeoptoelectronicdeviceincervicalcancerscreeningaprismacompliantsystematicreviewandmetaanalysis |