Cargando…
Coronary angiography using second-generation dual source computed tomography: Feasibility of low dose and low flow rate to achieve appropriate individual contrast enhancement using a test bolus-based contrast medium protocol—A CONSORT compliant article
Improved contrast enhancement consistency can be achieved using an individualized contrast media (CM) protocol. This study aimed to assess the feasibility of a low-dose, low-flow rate CM protocol to achieve appropriate individual contrast enhancement using a newly advocated individualized test bolus...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer Health
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6086535/ https://www.ncbi.nlm.nih.gov/pubmed/30024514 http://dx.doi.org/10.1097/MD.0000000000011425 |
_version_ | 1783346534701596672 |
---|---|
author | Zhu, Xiaomei Yu, Yusheng Xu, Dinghu Zhang, Hong Tang, Lijun |
author_facet | Zhu, Xiaomei Yu, Yusheng Xu, Dinghu Zhang, Hong Tang, Lijun |
author_sort | Zhu, Xiaomei |
collection | PubMed |
description | Improved contrast enhancement consistency can be achieved using an individualized contrast media (CM) protocol. This study aimed to assess the feasibility of a low-dose, low-flow rate CM protocol to achieve appropriate individual contrast enhancement using a newly advocated individualized test bolus-based protocol for second-generation dual-source computed tomography angiography. CM containing iodine (370 mg I/mL) was used in this study. A CM flow rate of 3.5 mL/s for patients with a body mass index (BMI) <25.0 kg/m(2), and 4.5 mL/s for those with BMI ≥25.0 kg/m(2) was used in group 1 (n = 189). An individualized test-bolus based contrast injection protocol was then derived from the information gained from the test bolus and coronary enhancements in group 1. The proposed individualized test-bolus based CM injection protocol was applied in group 2 (n = 219). Ascending aortic attenuations (AAo) were measured and compared with both groups. The contrast enhancement consistency of AAo in group 2 improved significantly (31.8 vs 56.3 Hounsfield units [HU]; P < .001). The number of patients in group 2 with a contrast flow rate ≤3 mL/s was 63 (28.8%), with 77 (35.2%) using a contrast dose ≤40 mL. In group 2, no significant differences in mean AAo were found among subgroups with contrast flow rates ≤3.0, 3.1 to 4.0, 4.1 to 5.0 and >5.0 mL/s (351, 344, 346, and 348 HU, respectively), nor among subgroups with contrast doses ≤40, 41 to 50, 51 to 60, and >60 mL (349, 345, 344, and 350 HU, respectively). Improved individual contrast enhancement uniformity can be achieved using an individualized CM protocol tailored to a test bolus. Approximately, one-third of patients received CM at a flow rate of no more than 3 mL/s and a total dose of no more than 40 mL. |
format | Online Article Text |
id | pubmed-6086535 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Wolters Kluwer Health |
record_format | MEDLINE/PubMed |
spelling | pubmed-60865352018-08-17 Coronary angiography using second-generation dual source computed tomography: Feasibility of low dose and low flow rate to achieve appropriate individual contrast enhancement using a test bolus-based contrast medium protocol—A CONSORT compliant article Zhu, Xiaomei Yu, Yusheng Xu, Dinghu Zhang, Hong Tang, Lijun Medicine (Baltimore) Research Article Improved contrast enhancement consistency can be achieved using an individualized contrast media (CM) protocol. This study aimed to assess the feasibility of a low-dose, low-flow rate CM protocol to achieve appropriate individual contrast enhancement using a newly advocated individualized test bolus-based protocol for second-generation dual-source computed tomography angiography. CM containing iodine (370 mg I/mL) was used in this study. A CM flow rate of 3.5 mL/s for patients with a body mass index (BMI) <25.0 kg/m(2), and 4.5 mL/s for those with BMI ≥25.0 kg/m(2) was used in group 1 (n = 189). An individualized test-bolus based contrast injection protocol was then derived from the information gained from the test bolus and coronary enhancements in group 1. The proposed individualized test-bolus based CM injection protocol was applied in group 2 (n = 219). Ascending aortic attenuations (AAo) were measured and compared with both groups. The contrast enhancement consistency of AAo in group 2 improved significantly (31.8 vs 56.3 Hounsfield units [HU]; P < .001). The number of patients in group 2 with a contrast flow rate ≤3 mL/s was 63 (28.8%), with 77 (35.2%) using a contrast dose ≤40 mL. In group 2, no significant differences in mean AAo were found among subgroups with contrast flow rates ≤3.0, 3.1 to 4.0, 4.1 to 5.0 and >5.0 mL/s (351, 344, 346, and 348 HU, respectively), nor among subgroups with contrast doses ≤40, 41 to 50, 51 to 60, and >60 mL (349, 345, 344, and 350 HU, respectively). Improved individual contrast enhancement uniformity can be achieved using an individualized CM protocol tailored to a test bolus. Approximately, one-third of patients received CM at a flow rate of no more than 3 mL/s and a total dose of no more than 40 mL. Wolters Kluwer Health 2018-07-20 /pmc/articles/PMC6086535/ /pubmed/30024514 http://dx.doi.org/10.1097/MD.0000000000011425 Text en Copyright © 2018 the Author(s). Published by Wolters Kluwer Health, Inc. http://creativecommons.org/licenses/by-nc/4.0 This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial License 4.0 (CCBY-NC), where it is permissible to download, share, remix, transform, and buildup the work provided it is properly cited. The work cannot be used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc/4.0 |
spellingShingle | Research Article Zhu, Xiaomei Yu, Yusheng Xu, Dinghu Zhang, Hong Tang, Lijun Coronary angiography using second-generation dual source computed tomography: Feasibility of low dose and low flow rate to achieve appropriate individual contrast enhancement using a test bolus-based contrast medium protocol—A CONSORT compliant article |
title | Coronary angiography using second-generation dual source computed tomography: Feasibility of low dose and low flow rate to achieve appropriate individual contrast enhancement using a test bolus-based contrast medium protocol—A CONSORT compliant article |
title_full | Coronary angiography using second-generation dual source computed tomography: Feasibility of low dose and low flow rate to achieve appropriate individual contrast enhancement using a test bolus-based contrast medium protocol—A CONSORT compliant article |
title_fullStr | Coronary angiography using second-generation dual source computed tomography: Feasibility of low dose and low flow rate to achieve appropriate individual contrast enhancement using a test bolus-based contrast medium protocol—A CONSORT compliant article |
title_full_unstemmed | Coronary angiography using second-generation dual source computed tomography: Feasibility of low dose and low flow rate to achieve appropriate individual contrast enhancement using a test bolus-based contrast medium protocol—A CONSORT compliant article |
title_short | Coronary angiography using second-generation dual source computed tomography: Feasibility of low dose and low flow rate to achieve appropriate individual contrast enhancement using a test bolus-based contrast medium protocol—A CONSORT compliant article |
title_sort | coronary angiography using second-generation dual source computed tomography: feasibility of low dose and low flow rate to achieve appropriate individual contrast enhancement using a test bolus-based contrast medium protocol—a consort compliant article |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6086535/ https://www.ncbi.nlm.nih.gov/pubmed/30024514 http://dx.doi.org/10.1097/MD.0000000000011425 |
work_keys_str_mv | AT zhuxiaomei coronaryangiographyusingsecondgenerationdualsourcecomputedtomographyfeasibilityoflowdoseandlowflowratetoachieveappropriateindividualcontrastenhancementusingatestbolusbasedcontrastmediumprotocolaconsortcompliantarticle AT yuyusheng coronaryangiographyusingsecondgenerationdualsourcecomputedtomographyfeasibilityoflowdoseandlowflowratetoachieveappropriateindividualcontrastenhancementusingatestbolusbasedcontrastmediumprotocolaconsortcompliantarticle AT xudinghu coronaryangiographyusingsecondgenerationdualsourcecomputedtomographyfeasibilityoflowdoseandlowflowratetoachieveappropriateindividualcontrastenhancementusingatestbolusbasedcontrastmediumprotocolaconsortcompliantarticle AT zhanghong coronaryangiographyusingsecondgenerationdualsourcecomputedtomographyfeasibilityoflowdoseandlowflowratetoachieveappropriateindividualcontrastenhancementusingatestbolusbasedcontrastmediumprotocolaconsortcompliantarticle AT tanglijun coronaryangiographyusingsecondgenerationdualsourcecomputedtomographyfeasibilityoflowdoseandlowflowratetoachieveappropriateindividualcontrastenhancementusingatestbolusbasedcontrastmediumprotocolaconsortcompliantarticle |