Cargando…

Coronary angiography using second-generation dual source computed tomography: Feasibility of low dose and low flow rate to achieve appropriate individual contrast enhancement using a test bolus-based contrast medium protocol—A CONSORT compliant article

Improved contrast enhancement consistency can be achieved using an individualized contrast media (CM) protocol. This study aimed to assess the feasibility of a low-dose, low-flow rate CM protocol to achieve appropriate individual contrast enhancement using a newly advocated individualized test bolus...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhu, Xiaomei, Yu, Yusheng, Xu, Dinghu, Zhang, Hong, Tang, Lijun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer Health 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6086535/
https://www.ncbi.nlm.nih.gov/pubmed/30024514
http://dx.doi.org/10.1097/MD.0000000000011425
_version_ 1783346534701596672
author Zhu, Xiaomei
Yu, Yusheng
Xu, Dinghu
Zhang, Hong
Tang, Lijun
author_facet Zhu, Xiaomei
Yu, Yusheng
Xu, Dinghu
Zhang, Hong
Tang, Lijun
author_sort Zhu, Xiaomei
collection PubMed
description Improved contrast enhancement consistency can be achieved using an individualized contrast media (CM) protocol. This study aimed to assess the feasibility of a low-dose, low-flow rate CM protocol to achieve appropriate individual contrast enhancement using a newly advocated individualized test bolus-based protocol for second-generation dual-source computed tomography angiography. CM containing iodine (370 mg I/mL) was used in this study. A CM flow rate of 3.5 mL/s for patients with a body mass index (BMI) <25.0 kg/m(2), and 4.5 mL/s for those with BMI ≥25.0 kg/m(2) was used in group 1 (n = 189). An individualized test-bolus based contrast injection protocol was then derived from the information gained from the test bolus and coronary enhancements in group 1. The proposed individualized test-bolus based CM injection protocol was applied in group 2 (n = 219). Ascending aortic attenuations (AAo) were measured and compared with both groups. The contrast enhancement consistency of AAo in group 2 improved significantly (31.8 vs 56.3 Hounsfield units [HU]; P < .001). The number of patients in group 2 with a contrast flow rate ≤3 mL/s was 63 (28.8%), with 77 (35.2%) using a contrast dose ≤40 mL. In group 2, no significant differences in mean AAo were found among subgroups with contrast flow rates ≤3.0, 3.1 to 4.0, 4.1 to 5.0 and >5.0 mL/s (351, 344, 346, and 348 HU, respectively), nor among subgroups with contrast doses ≤40, 41 to 50, 51 to 60, and >60 mL (349, 345, 344, and 350 HU, respectively). Improved individual contrast enhancement uniformity can be achieved using an individualized CM protocol tailored to a test bolus. Approximately, one-third of patients received CM at a flow rate of no more than 3 mL/s and a total dose of no more than 40 mL.
format Online
Article
Text
id pubmed-6086535
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Wolters Kluwer Health
record_format MEDLINE/PubMed
spelling pubmed-60865352018-08-17 Coronary angiography using second-generation dual source computed tomography: Feasibility of low dose and low flow rate to achieve appropriate individual contrast enhancement using a test bolus-based contrast medium protocol—A CONSORT compliant article Zhu, Xiaomei Yu, Yusheng Xu, Dinghu Zhang, Hong Tang, Lijun Medicine (Baltimore) Research Article Improved contrast enhancement consistency can be achieved using an individualized contrast media (CM) protocol. This study aimed to assess the feasibility of a low-dose, low-flow rate CM protocol to achieve appropriate individual contrast enhancement using a newly advocated individualized test bolus-based protocol for second-generation dual-source computed tomography angiography. CM containing iodine (370 mg I/mL) was used in this study. A CM flow rate of 3.5 mL/s for patients with a body mass index (BMI) <25.0 kg/m(2), and 4.5 mL/s for those with BMI ≥25.0 kg/m(2) was used in group 1 (n = 189). An individualized test-bolus based contrast injection protocol was then derived from the information gained from the test bolus and coronary enhancements in group 1. The proposed individualized test-bolus based CM injection protocol was applied in group 2 (n = 219). Ascending aortic attenuations (AAo) were measured and compared with both groups. The contrast enhancement consistency of AAo in group 2 improved significantly (31.8 vs 56.3 Hounsfield units [HU]; P < .001). The number of patients in group 2 with a contrast flow rate ≤3 mL/s was 63 (28.8%), with 77 (35.2%) using a contrast dose ≤40 mL. In group 2, no significant differences in mean AAo were found among subgroups with contrast flow rates ≤3.0, 3.1 to 4.0, 4.1 to 5.0 and >5.0 mL/s (351, 344, 346, and 348 HU, respectively), nor among subgroups with contrast doses ≤40, 41 to 50, 51 to 60, and >60 mL (349, 345, 344, and 350 HU, respectively). Improved individual contrast enhancement uniformity can be achieved using an individualized CM protocol tailored to a test bolus. Approximately, one-third of patients received CM at a flow rate of no more than 3 mL/s and a total dose of no more than 40 mL. Wolters Kluwer Health 2018-07-20 /pmc/articles/PMC6086535/ /pubmed/30024514 http://dx.doi.org/10.1097/MD.0000000000011425 Text en Copyright © 2018 the Author(s). Published by Wolters Kluwer Health, Inc. http://creativecommons.org/licenses/by-nc/4.0 This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial License 4.0 (CCBY-NC), where it is permissible to download, share, remix, transform, and buildup the work provided it is properly cited. The work cannot be used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc/4.0
spellingShingle Research Article
Zhu, Xiaomei
Yu, Yusheng
Xu, Dinghu
Zhang, Hong
Tang, Lijun
Coronary angiography using second-generation dual source computed tomography: Feasibility of low dose and low flow rate to achieve appropriate individual contrast enhancement using a test bolus-based contrast medium protocol—A CONSORT compliant article
title Coronary angiography using second-generation dual source computed tomography: Feasibility of low dose and low flow rate to achieve appropriate individual contrast enhancement using a test bolus-based contrast medium protocol—A CONSORT compliant article
title_full Coronary angiography using second-generation dual source computed tomography: Feasibility of low dose and low flow rate to achieve appropriate individual contrast enhancement using a test bolus-based contrast medium protocol—A CONSORT compliant article
title_fullStr Coronary angiography using second-generation dual source computed tomography: Feasibility of low dose and low flow rate to achieve appropriate individual contrast enhancement using a test bolus-based contrast medium protocol—A CONSORT compliant article
title_full_unstemmed Coronary angiography using second-generation dual source computed tomography: Feasibility of low dose and low flow rate to achieve appropriate individual contrast enhancement using a test bolus-based contrast medium protocol—A CONSORT compliant article
title_short Coronary angiography using second-generation dual source computed tomography: Feasibility of low dose and low flow rate to achieve appropriate individual contrast enhancement using a test bolus-based contrast medium protocol—A CONSORT compliant article
title_sort coronary angiography using second-generation dual source computed tomography: feasibility of low dose and low flow rate to achieve appropriate individual contrast enhancement using a test bolus-based contrast medium protocol—a consort compliant article
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6086535/
https://www.ncbi.nlm.nih.gov/pubmed/30024514
http://dx.doi.org/10.1097/MD.0000000000011425
work_keys_str_mv AT zhuxiaomei coronaryangiographyusingsecondgenerationdualsourcecomputedtomographyfeasibilityoflowdoseandlowflowratetoachieveappropriateindividualcontrastenhancementusingatestbolusbasedcontrastmediumprotocolaconsortcompliantarticle
AT yuyusheng coronaryangiographyusingsecondgenerationdualsourcecomputedtomographyfeasibilityoflowdoseandlowflowratetoachieveappropriateindividualcontrastenhancementusingatestbolusbasedcontrastmediumprotocolaconsortcompliantarticle
AT xudinghu coronaryangiographyusingsecondgenerationdualsourcecomputedtomographyfeasibilityoflowdoseandlowflowratetoachieveappropriateindividualcontrastenhancementusingatestbolusbasedcontrastmediumprotocolaconsortcompliantarticle
AT zhanghong coronaryangiographyusingsecondgenerationdualsourcecomputedtomographyfeasibilityoflowdoseandlowflowratetoachieveappropriateindividualcontrastenhancementusingatestbolusbasedcontrastmediumprotocolaconsortcompliantarticle
AT tanglijun coronaryangiographyusingsecondgenerationdualsourcecomputedtomographyfeasibilityoflowdoseandlowflowratetoachieveappropriateindividualcontrastenhancementusingatestbolusbasedcontrastmediumprotocolaconsortcompliantarticle