Cargando…

X-ray micro-computed tomography (μCT): an emerging opportunity in parasite imaging

X-ray micro-computed tomography (μCT) is a technique which can obtain three-dimensional images of a sample, including its internal structure, without the need for destructive sectioning. Here, we review the capability of the technique and examine its potential to provide novel insights into the life...

Descripción completa

Detalles Bibliográficos
Autores principales: O'Sullivan, James D. B., Behnsen, Julia, Starborg, Tobias, MacDonald, Andrew S., Phythian-Adams, Alexander T., Else, Kathryn J., Cruickshank, Sheena M., Withers, Philip J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cambridge University Press 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6088774/
https://www.ncbi.nlm.nih.gov/pubmed/29179788
http://dx.doi.org/10.1017/S0031182017002074
_version_ 1783346901962194944
author O'Sullivan, James D. B.
Behnsen, Julia
Starborg, Tobias
MacDonald, Andrew S.
Phythian-Adams, Alexander T.
Else, Kathryn J.
Cruickshank, Sheena M.
Withers, Philip J.
author_facet O'Sullivan, James D. B.
Behnsen, Julia
Starborg, Tobias
MacDonald, Andrew S.
Phythian-Adams, Alexander T.
Else, Kathryn J.
Cruickshank, Sheena M.
Withers, Philip J.
author_sort O'Sullivan, James D. B.
collection PubMed
description X-ray micro-computed tomography (μCT) is a technique which can obtain three-dimensional images of a sample, including its internal structure, without the need for destructive sectioning. Here, we review the capability of the technique and examine its potential to provide novel insights into the lifestyles of parasites embedded within host tissue. The current capabilities and limitations of the technology in producing contrast in soft tissues are discussed, as well as the potential solutions for parasitologists looking to apply this technique. We present example images of the mouse whipworm Trichuris muris and discuss the application of μCT to provide unique insights into parasite behaviour and pathology, which are inaccessible to other imaging modalities.
format Online
Article
Text
id pubmed-6088774
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Cambridge University Press
record_format MEDLINE/PubMed
spelling pubmed-60887742018-08-16 X-ray micro-computed tomography (μCT): an emerging opportunity in parasite imaging O'Sullivan, James D. B. Behnsen, Julia Starborg, Tobias MacDonald, Andrew S. Phythian-Adams, Alexander T. Else, Kathryn J. Cruickshank, Sheena M. Withers, Philip J. Parasitology Review Article X-ray micro-computed tomography (μCT) is a technique which can obtain three-dimensional images of a sample, including its internal structure, without the need for destructive sectioning. Here, we review the capability of the technique and examine its potential to provide novel insights into the lifestyles of parasites embedded within host tissue. The current capabilities and limitations of the technology in producing contrast in soft tissues are discussed, as well as the potential solutions for parasitologists looking to apply this technique. We present example images of the mouse whipworm Trichuris muris and discuss the application of μCT to provide unique insights into parasite behaviour and pathology, which are inaccessible to other imaging modalities. Cambridge University Press 2018-06 2017-11-28 /pmc/articles/PMC6088774/ /pubmed/29179788 http://dx.doi.org/10.1017/S0031182017002074 Text en © Cambridge University Press 2017 http://creativecommons.org/licenses/by/4.0/ This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted re-use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Review Article
O'Sullivan, James D. B.
Behnsen, Julia
Starborg, Tobias
MacDonald, Andrew S.
Phythian-Adams, Alexander T.
Else, Kathryn J.
Cruickshank, Sheena M.
Withers, Philip J.
X-ray micro-computed tomography (μCT): an emerging opportunity in parasite imaging
title X-ray micro-computed tomography (μCT): an emerging opportunity in parasite imaging
title_full X-ray micro-computed tomography (μCT): an emerging opportunity in parasite imaging
title_fullStr X-ray micro-computed tomography (μCT): an emerging opportunity in parasite imaging
title_full_unstemmed X-ray micro-computed tomography (μCT): an emerging opportunity in parasite imaging
title_short X-ray micro-computed tomography (μCT): an emerging opportunity in parasite imaging
title_sort x-ray micro-computed tomography (μct): an emerging opportunity in parasite imaging
topic Review Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6088774/
https://www.ncbi.nlm.nih.gov/pubmed/29179788
http://dx.doi.org/10.1017/S0031182017002074
work_keys_str_mv AT osullivanjamesdb xraymicrocomputedtomographymctanemergingopportunityinparasiteimaging
AT behnsenjulia xraymicrocomputedtomographymctanemergingopportunityinparasiteimaging
AT starborgtobias xraymicrocomputedtomographymctanemergingopportunityinparasiteimaging
AT macdonaldandrews xraymicrocomputedtomographymctanemergingopportunityinparasiteimaging
AT phythianadamsalexandert xraymicrocomputedtomographymctanemergingopportunityinparasiteimaging
AT elsekathrynj xraymicrocomputedtomographymctanemergingopportunityinparasiteimaging
AT cruickshanksheenam xraymicrocomputedtomographymctanemergingopportunityinparasiteimaging
AT withersphilipj xraymicrocomputedtomographymctanemergingopportunityinparasiteimaging