Cargando…

To intubate or not: ventilation is the question. A manikin-based observational study

INTRODUCTION: There is a continuous debate concerning the superiority of endotracheal intubation on bag-valve-mask (BVM) ventilation in patients with cardiac arrest. In this manikin-based observational study, we evaluate and compare the performance of manual ventilation through a facemask (BVM) and...

Descripción completa

Detalles Bibliográficos
Autores principales: Sall, Fatimata Seydou, De Luca, Alban, Pazart, Lionel, Pugin, Aurore, Capellier, Gilles, Khoury, Abdo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BMJ Publishing Group 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6089311/
https://www.ncbi.nlm.nih.gov/pubmed/30116535
http://dx.doi.org/10.1136/bmjresp-2017-000261
_version_ 1783347001281216512
author Sall, Fatimata Seydou
De Luca, Alban
Pazart, Lionel
Pugin, Aurore
Capellier, Gilles
Khoury, Abdo
author_facet Sall, Fatimata Seydou
De Luca, Alban
Pazart, Lionel
Pugin, Aurore
Capellier, Gilles
Khoury, Abdo
author_sort Sall, Fatimata Seydou
collection PubMed
description INTRODUCTION: There is a continuous debate concerning the superiority of endotracheal intubation on bag-valve-mask (BVM) ventilation in patients with cardiac arrest. In this manikin-based observational study, we evaluate and compare the performance of manual ventilation through a facemask (BVM) and an endotracheal tube (ETT). METHODS: One hundred and forty healthcare providers were instructed to manually ventilate a manikin as they would do for a 75 kg adult patient in respiratory arrest. Each one was ventilating both through a facemask and an ETT for a 5 min period in a random order. Ventilatory parameters were measured by the ASL 5000 lung simulator and ventilation performance was analysed using a sliding window method published in a previous study to assess accurately ventilation efficiency. RESULTS: The mean ventilation rate was high whatever the technique used (24 bpm). A weak relationship between manual ventilation performance and the type of interface used was observed (p=0.0484). The overall rate of adequate ventilation was low even if we noticed a slight improvement when ventilating through an ETT (13.21% vs 7.5% of adequate ventilation). However, the rate of hyperventilation did not differ between mask and tube (79% vs 77%). A significant relationship is observed between professional category, the size of the hand squeezing the bag and manual ventilation performance (p<0.05). CONCLUSION: Whatever the interface used, healthcare professionals are still struggling to perform manual ventilation efficiently according to international guidelines. Ventilation with an ETT does not prove to be significantly more efficient than with a facemask. It would be therefore important to recentre the debate on controlling ventilatory parameters with current devices. Focusing on training may maximise manual ventilation efficiency and minimise the loss of time during cardiopulmonary resuscitation.
format Online
Article
Text
id pubmed-6089311
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher BMJ Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-60893112018-08-16 To intubate or not: ventilation is the question. A manikin-based observational study Sall, Fatimata Seydou De Luca, Alban Pazart, Lionel Pugin, Aurore Capellier, Gilles Khoury, Abdo BMJ Open Respir Res Non-Invasive Ventilation INTRODUCTION: There is a continuous debate concerning the superiority of endotracheal intubation on bag-valve-mask (BVM) ventilation in patients with cardiac arrest. In this manikin-based observational study, we evaluate and compare the performance of manual ventilation through a facemask (BVM) and an endotracheal tube (ETT). METHODS: One hundred and forty healthcare providers were instructed to manually ventilate a manikin as they would do for a 75 kg adult patient in respiratory arrest. Each one was ventilating both through a facemask and an ETT for a 5 min period in a random order. Ventilatory parameters were measured by the ASL 5000 lung simulator and ventilation performance was analysed using a sliding window method published in a previous study to assess accurately ventilation efficiency. RESULTS: The mean ventilation rate was high whatever the technique used (24 bpm). A weak relationship between manual ventilation performance and the type of interface used was observed (p=0.0484). The overall rate of adequate ventilation was low even if we noticed a slight improvement when ventilating through an ETT (13.21% vs 7.5% of adequate ventilation). However, the rate of hyperventilation did not differ between mask and tube (79% vs 77%). A significant relationship is observed between professional category, the size of the hand squeezing the bag and manual ventilation performance (p<0.05). CONCLUSION: Whatever the interface used, healthcare professionals are still struggling to perform manual ventilation efficiently according to international guidelines. Ventilation with an ETT does not prove to be significantly more efficient than with a facemask. It would be therefore important to recentre the debate on controlling ventilatory parameters with current devices. Focusing on training may maximise manual ventilation efficiency and minimise the loss of time during cardiopulmonary resuscitation. BMJ Publishing Group 2018-07-17 /pmc/articles/PMC6089311/ /pubmed/30116535 http://dx.doi.org/10.1136/bmjresp-2017-000261 Text en © Author(s) (or their employer(s)) 2018. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ. This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/.
spellingShingle Non-Invasive Ventilation
Sall, Fatimata Seydou
De Luca, Alban
Pazart, Lionel
Pugin, Aurore
Capellier, Gilles
Khoury, Abdo
To intubate or not: ventilation is the question. A manikin-based observational study
title To intubate or not: ventilation is the question. A manikin-based observational study
title_full To intubate or not: ventilation is the question. A manikin-based observational study
title_fullStr To intubate or not: ventilation is the question. A manikin-based observational study
title_full_unstemmed To intubate or not: ventilation is the question. A manikin-based observational study
title_short To intubate or not: ventilation is the question. A manikin-based observational study
title_sort to intubate or not: ventilation is the question. a manikin-based observational study
topic Non-Invasive Ventilation
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6089311/
https://www.ncbi.nlm.nih.gov/pubmed/30116535
http://dx.doi.org/10.1136/bmjresp-2017-000261
work_keys_str_mv AT sallfatimataseydou tointubateornotventilationisthequestionamanikinbasedobservationalstudy
AT delucaalban tointubateornotventilationisthequestionamanikinbasedobservationalstudy
AT pazartlionel tointubateornotventilationisthequestionamanikinbasedobservationalstudy
AT puginaurore tointubateornotventilationisthequestionamanikinbasedobservationalstudy
AT capelliergilles tointubateornotventilationisthequestionamanikinbasedobservationalstudy
AT khouryabdo tointubateornotventilationisthequestionamanikinbasedobservationalstudy