Cargando…

Improvement of Mycobacterium tuberculosis detection by Xpert MTB/RIF Ultra: A head-to-head comparison on Xpert-negative samples

BACKGROUND: The new Xpert MTB/RIF Ultra assay (Ultra, Cepheid, Sunnyvale, USA) is a cartridge-based automated diagnostic test that can simultaneously identify Mycobacterium tuberculosis complex (MTB) and resistance to Rifampicin (RIF). With respect to the previous version Xpert MTB/RIF assay (Xpert)...

Descripción completa

Detalles Bibliográficos
Autores principales: Bisognin, Francesco, Lombardi, Giulia, Lombardo, Donatella, Re, Maria Carla, Dal Monte, Paola
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6089413/
https://www.ncbi.nlm.nih.gov/pubmed/30102737
http://dx.doi.org/10.1371/journal.pone.0201934
_version_ 1783347014915850240
author Bisognin, Francesco
Lombardi, Giulia
Lombardo, Donatella
Re, Maria Carla
Dal Monte, Paola
author_facet Bisognin, Francesco
Lombardi, Giulia
Lombardo, Donatella
Re, Maria Carla
Dal Monte, Paola
author_sort Bisognin, Francesco
collection PubMed
description BACKGROUND: The new Xpert MTB/RIF Ultra assay (Ultra, Cepheid, Sunnyvale, USA) is a cartridge-based automated diagnostic test that can simultaneously identify Mycobacterium tuberculosis complex (MTB) and resistance to Rifampicin (RIF). With respect to the previous version Xpert MTB/RIF assay (Xpert), IS6110/IS1081 repetitive elements probes have been added allowing the detection of lower MTB load, defined by the new semi-quantitative category “trace” with indeterminate RIF resistance. The aim of this study was to evaluate performance of the new version Ultra on Xpert-negative, but TB culture-positive clinical samples. METHODS: The de-identified frozen samples (-20 °C) collected over a 4-year period (February 2014-October 2017), which had previously resulted smear-negative, Xpert-negative but MTB culture-positive, were analyzed with Ultra. The de-frosted samples were loaded into the cartridge using the same process as the previous version, according to manufacturer’s instruction. RESULTS: During the study period 382 MTB culture-positive samples were archived: 314 resulted Xpert-positive and 68 Xpert-negative. Thirty-one of the 68 Xpert-negative samples resulted positive with Ultra, with an overall improvement in MTB detection of 45.6%. Out of 36 Xpert-negative respiratory samples, 18 resulted Ultra-positive with the following semi-quantitative loads: “low”(n = 1), “very low”(n = 11), “trace”(n = 6), with an improvement in MTB detection of 50%. The best performance was achieved on bronchoalveolar lavage specimens (53.8%). Out of 32 Xpert-negative non-respiratory samples, 13 resulted Ultra-positive with the following semi-quantitative loads: “very low”(n = 7), “trace”(n = 6), with an improvement in MTB detection of 40.6%. The best performance was achieved on biopsies (55.6%) and lymph nodes (50%). The new category “trace” detected 12 out of the 31 Ultra-positive MTB samples; in the remaining 19 samples RIF susceptibility was determined with 100% concordance with the phenotypic susceptibility test. The mean time to positivity of samples found negative by Ultra was significantly longer in comparison to positive samples in liquid culture. CONCLUSIONS: Our results are consistent with the few studies published so far and confirm the better performance of Ultra compared to the previous version in both respiratory and non-respiratory smear-negative samples, with an overall improvement of 45.6%.
format Online
Article
Text
id pubmed-6089413
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-60894132018-08-30 Improvement of Mycobacterium tuberculosis detection by Xpert MTB/RIF Ultra: A head-to-head comparison on Xpert-negative samples Bisognin, Francesco Lombardi, Giulia Lombardo, Donatella Re, Maria Carla Dal Monte, Paola PLoS One Research Article BACKGROUND: The new Xpert MTB/RIF Ultra assay (Ultra, Cepheid, Sunnyvale, USA) is a cartridge-based automated diagnostic test that can simultaneously identify Mycobacterium tuberculosis complex (MTB) and resistance to Rifampicin (RIF). With respect to the previous version Xpert MTB/RIF assay (Xpert), IS6110/IS1081 repetitive elements probes have been added allowing the detection of lower MTB load, defined by the new semi-quantitative category “trace” with indeterminate RIF resistance. The aim of this study was to evaluate performance of the new version Ultra on Xpert-negative, but TB culture-positive clinical samples. METHODS: The de-identified frozen samples (-20 °C) collected over a 4-year period (February 2014-October 2017), which had previously resulted smear-negative, Xpert-negative but MTB culture-positive, were analyzed with Ultra. The de-frosted samples were loaded into the cartridge using the same process as the previous version, according to manufacturer’s instruction. RESULTS: During the study period 382 MTB culture-positive samples were archived: 314 resulted Xpert-positive and 68 Xpert-negative. Thirty-one of the 68 Xpert-negative samples resulted positive with Ultra, with an overall improvement in MTB detection of 45.6%. Out of 36 Xpert-negative respiratory samples, 18 resulted Ultra-positive with the following semi-quantitative loads: “low”(n = 1), “very low”(n = 11), “trace”(n = 6), with an improvement in MTB detection of 50%. The best performance was achieved on bronchoalveolar lavage specimens (53.8%). Out of 32 Xpert-negative non-respiratory samples, 13 resulted Ultra-positive with the following semi-quantitative loads: “very low”(n = 7), “trace”(n = 6), with an improvement in MTB detection of 40.6%. The best performance was achieved on biopsies (55.6%) and lymph nodes (50%). The new category “trace” detected 12 out of the 31 Ultra-positive MTB samples; in the remaining 19 samples RIF susceptibility was determined with 100% concordance with the phenotypic susceptibility test. The mean time to positivity of samples found negative by Ultra was significantly longer in comparison to positive samples in liquid culture. CONCLUSIONS: Our results are consistent with the few studies published so far and confirm the better performance of Ultra compared to the previous version in both respiratory and non-respiratory smear-negative samples, with an overall improvement of 45.6%. Public Library of Science 2018-08-13 /pmc/articles/PMC6089413/ /pubmed/30102737 http://dx.doi.org/10.1371/journal.pone.0201934 Text en © 2018 Bisognin et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Bisognin, Francesco
Lombardi, Giulia
Lombardo, Donatella
Re, Maria Carla
Dal Monte, Paola
Improvement of Mycobacterium tuberculosis detection by Xpert MTB/RIF Ultra: A head-to-head comparison on Xpert-negative samples
title Improvement of Mycobacterium tuberculosis detection by Xpert MTB/RIF Ultra: A head-to-head comparison on Xpert-negative samples
title_full Improvement of Mycobacterium tuberculosis detection by Xpert MTB/RIF Ultra: A head-to-head comparison on Xpert-negative samples
title_fullStr Improvement of Mycobacterium tuberculosis detection by Xpert MTB/RIF Ultra: A head-to-head comparison on Xpert-negative samples
title_full_unstemmed Improvement of Mycobacterium tuberculosis detection by Xpert MTB/RIF Ultra: A head-to-head comparison on Xpert-negative samples
title_short Improvement of Mycobacterium tuberculosis detection by Xpert MTB/RIF Ultra: A head-to-head comparison on Xpert-negative samples
title_sort improvement of mycobacterium tuberculosis detection by xpert mtb/rif ultra: a head-to-head comparison on xpert-negative samples
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6089413/
https://www.ncbi.nlm.nih.gov/pubmed/30102737
http://dx.doi.org/10.1371/journal.pone.0201934
work_keys_str_mv AT bisogninfrancesco improvementofmycobacteriumtuberculosisdetectionbyxpertmtbrifultraaheadtoheadcomparisononxpertnegativesamples
AT lombardigiulia improvementofmycobacteriumtuberculosisdetectionbyxpertmtbrifultraaheadtoheadcomparisononxpertnegativesamples
AT lombardodonatella improvementofmycobacteriumtuberculosisdetectionbyxpertmtbrifultraaheadtoheadcomparisononxpertnegativesamples
AT remariacarla improvementofmycobacteriumtuberculosisdetectionbyxpertmtbrifultraaheadtoheadcomparisononxpertnegativesamples
AT dalmontepaola improvementofmycobacteriumtuberculosisdetectionbyxpertmtbrifultraaheadtoheadcomparisononxpertnegativesamples