Cargando…
Improvement of Mycobacterium tuberculosis detection by Xpert MTB/RIF Ultra: A head-to-head comparison on Xpert-negative samples
BACKGROUND: The new Xpert MTB/RIF Ultra assay (Ultra, Cepheid, Sunnyvale, USA) is a cartridge-based automated diagnostic test that can simultaneously identify Mycobacterium tuberculosis complex (MTB) and resistance to Rifampicin (RIF). With respect to the previous version Xpert MTB/RIF assay (Xpert)...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6089413/ https://www.ncbi.nlm.nih.gov/pubmed/30102737 http://dx.doi.org/10.1371/journal.pone.0201934 |
_version_ | 1783347014915850240 |
---|---|
author | Bisognin, Francesco Lombardi, Giulia Lombardo, Donatella Re, Maria Carla Dal Monte, Paola |
author_facet | Bisognin, Francesco Lombardi, Giulia Lombardo, Donatella Re, Maria Carla Dal Monte, Paola |
author_sort | Bisognin, Francesco |
collection | PubMed |
description | BACKGROUND: The new Xpert MTB/RIF Ultra assay (Ultra, Cepheid, Sunnyvale, USA) is a cartridge-based automated diagnostic test that can simultaneously identify Mycobacterium tuberculosis complex (MTB) and resistance to Rifampicin (RIF). With respect to the previous version Xpert MTB/RIF assay (Xpert), IS6110/IS1081 repetitive elements probes have been added allowing the detection of lower MTB load, defined by the new semi-quantitative category “trace” with indeterminate RIF resistance. The aim of this study was to evaluate performance of the new version Ultra on Xpert-negative, but TB culture-positive clinical samples. METHODS: The de-identified frozen samples (-20 °C) collected over a 4-year period (February 2014-October 2017), which had previously resulted smear-negative, Xpert-negative but MTB culture-positive, were analyzed with Ultra. The de-frosted samples were loaded into the cartridge using the same process as the previous version, according to manufacturer’s instruction. RESULTS: During the study period 382 MTB culture-positive samples were archived: 314 resulted Xpert-positive and 68 Xpert-negative. Thirty-one of the 68 Xpert-negative samples resulted positive with Ultra, with an overall improvement in MTB detection of 45.6%. Out of 36 Xpert-negative respiratory samples, 18 resulted Ultra-positive with the following semi-quantitative loads: “low”(n = 1), “very low”(n = 11), “trace”(n = 6), with an improvement in MTB detection of 50%. The best performance was achieved on bronchoalveolar lavage specimens (53.8%). Out of 32 Xpert-negative non-respiratory samples, 13 resulted Ultra-positive with the following semi-quantitative loads: “very low”(n = 7), “trace”(n = 6), with an improvement in MTB detection of 40.6%. The best performance was achieved on biopsies (55.6%) and lymph nodes (50%). The new category “trace” detected 12 out of the 31 Ultra-positive MTB samples; in the remaining 19 samples RIF susceptibility was determined with 100% concordance with the phenotypic susceptibility test. The mean time to positivity of samples found negative by Ultra was significantly longer in comparison to positive samples in liquid culture. CONCLUSIONS: Our results are consistent with the few studies published so far and confirm the better performance of Ultra compared to the previous version in both respiratory and non-respiratory smear-negative samples, with an overall improvement of 45.6%. |
format | Online Article Text |
id | pubmed-6089413 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-60894132018-08-30 Improvement of Mycobacterium tuberculosis detection by Xpert MTB/RIF Ultra: A head-to-head comparison on Xpert-negative samples Bisognin, Francesco Lombardi, Giulia Lombardo, Donatella Re, Maria Carla Dal Monte, Paola PLoS One Research Article BACKGROUND: The new Xpert MTB/RIF Ultra assay (Ultra, Cepheid, Sunnyvale, USA) is a cartridge-based automated diagnostic test that can simultaneously identify Mycobacterium tuberculosis complex (MTB) and resistance to Rifampicin (RIF). With respect to the previous version Xpert MTB/RIF assay (Xpert), IS6110/IS1081 repetitive elements probes have been added allowing the detection of lower MTB load, defined by the new semi-quantitative category “trace” with indeterminate RIF resistance. The aim of this study was to evaluate performance of the new version Ultra on Xpert-negative, but TB culture-positive clinical samples. METHODS: The de-identified frozen samples (-20 °C) collected over a 4-year period (February 2014-October 2017), which had previously resulted smear-negative, Xpert-negative but MTB culture-positive, were analyzed with Ultra. The de-frosted samples were loaded into the cartridge using the same process as the previous version, according to manufacturer’s instruction. RESULTS: During the study period 382 MTB culture-positive samples were archived: 314 resulted Xpert-positive and 68 Xpert-negative. Thirty-one of the 68 Xpert-negative samples resulted positive with Ultra, with an overall improvement in MTB detection of 45.6%. Out of 36 Xpert-negative respiratory samples, 18 resulted Ultra-positive with the following semi-quantitative loads: “low”(n = 1), “very low”(n = 11), “trace”(n = 6), with an improvement in MTB detection of 50%. The best performance was achieved on bronchoalveolar lavage specimens (53.8%). Out of 32 Xpert-negative non-respiratory samples, 13 resulted Ultra-positive with the following semi-quantitative loads: “very low”(n = 7), “trace”(n = 6), with an improvement in MTB detection of 40.6%. The best performance was achieved on biopsies (55.6%) and lymph nodes (50%). The new category “trace” detected 12 out of the 31 Ultra-positive MTB samples; in the remaining 19 samples RIF susceptibility was determined with 100% concordance with the phenotypic susceptibility test. The mean time to positivity of samples found negative by Ultra was significantly longer in comparison to positive samples in liquid culture. CONCLUSIONS: Our results are consistent with the few studies published so far and confirm the better performance of Ultra compared to the previous version in both respiratory and non-respiratory smear-negative samples, with an overall improvement of 45.6%. Public Library of Science 2018-08-13 /pmc/articles/PMC6089413/ /pubmed/30102737 http://dx.doi.org/10.1371/journal.pone.0201934 Text en © 2018 Bisognin et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Bisognin, Francesco Lombardi, Giulia Lombardo, Donatella Re, Maria Carla Dal Monte, Paola Improvement of Mycobacterium tuberculosis detection by Xpert MTB/RIF Ultra: A head-to-head comparison on Xpert-negative samples |
title | Improvement of Mycobacterium tuberculosis detection by Xpert MTB/RIF Ultra: A head-to-head comparison on Xpert-negative samples |
title_full | Improvement of Mycobacterium tuberculosis detection by Xpert MTB/RIF Ultra: A head-to-head comparison on Xpert-negative samples |
title_fullStr | Improvement of Mycobacterium tuberculosis detection by Xpert MTB/RIF Ultra: A head-to-head comparison on Xpert-negative samples |
title_full_unstemmed | Improvement of Mycobacterium tuberculosis detection by Xpert MTB/RIF Ultra: A head-to-head comparison on Xpert-negative samples |
title_short | Improvement of Mycobacterium tuberculosis detection by Xpert MTB/RIF Ultra: A head-to-head comparison on Xpert-negative samples |
title_sort | improvement of mycobacterium tuberculosis detection by xpert mtb/rif ultra: a head-to-head comparison on xpert-negative samples |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6089413/ https://www.ncbi.nlm.nih.gov/pubmed/30102737 http://dx.doi.org/10.1371/journal.pone.0201934 |
work_keys_str_mv | AT bisogninfrancesco improvementofmycobacteriumtuberculosisdetectionbyxpertmtbrifultraaheadtoheadcomparisononxpertnegativesamples AT lombardigiulia improvementofmycobacteriumtuberculosisdetectionbyxpertmtbrifultraaheadtoheadcomparisononxpertnegativesamples AT lombardodonatella improvementofmycobacteriumtuberculosisdetectionbyxpertmtbrifultraaheadtoheadcomparisononxpertnegativesamples AT remariacarla improvementofmycobacteriumtuberculosisdetectionbyxpertmtbrifultraaheadtoheadcomparisononxpertnegativesamples AT dalmontepaola improvementofmycobacteriumtuberculosisdetectionbyxpertmtbrifultraaheadtoheadcomparisononxpertnegativesamples |