Cargando…
Impact of the third generation cryoballoon on atrial fibrillation ablation: An useful tool?
BACKGROUND: Third-generation cryoballoon (CB3) is characterized by a 40% shorter distal tip designed to increase the rate of pulmonary veins real-time signal recording in order to measure time necessary to isolate veins, the “Time to effect” (TTE). Few data are currently available on clinical follow...
Autores principales: | , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6090001/ https://www.ncbi.nlm.nih.gov/pubmed/29476904 http://dx.doi.org/10.1016/j.ipej.2018.02.003 |
_version_ | 1783347118864334848 |
---|---|
author | Sciarra, Luigi Iacopino, Saverio Palamà, Zefferino De Ruvo, Ermenegildo Filannino, Pasquale Borrelli, Alessio Artale, Paolo Caragliano, Alberto Scarà, Antonio Golia, Paolo De Luca, Lucia Grieco, Domenico Rebecchi, Marco Favale, Stefano Calò, Leonardo |
author_facet | Sciarra, Luigi Iacopino, Saverio Palamà, Zefferino De Ruvo, Ermenegildo Filannino, Pasquale Borrelli, Alessio Artale, Paolo Caragliano, Alberto Scarà, Antonio Golia, Paolo De Luca, Lucia Grieco, Domenico Rebecchi, Marco Favale, Stefano Calò, Leonardo |
author_sort | Sciarra, Luigi |
collection | PubMed |
description | BACKGROUND: Third-generation cryoballoon (CB3) is characterized by a 40% shorter distal tip designed to increase the rate of pulmonary veins real-time signal recording in order to measure time necessary to isolate veins, the “Time to effect” (TTE). Few data are currently available on clinical follow up of CB3 treated patients. METHODS: Sixtyeight consecutive patients (mean age 57.8 ± 9.6 years, 48 male) with paroxysmal or persistent atrial fibrillation (AF) were enrolled. Thirthyfour (25 paroxysmal AF) underwent to a 28 mmCB3 pulmonary veins isolation and were compared to 34 treated (21 paroxysmal AF) with 28 mmCB2. RESULTS: CB3 use was correlated to significant increase of the possibility to measure TTE in every treated veins (left superior 82,35% vs 23,53%, left inferior 70,59% vs 38,24%, right superior 58,82% vs 14,71%, right inferior 52,94% vs 17,65%). When it is measured, TTE wasn't different between two groups. Higher nadir temperature was observed in CB3 patients (−39.4 ± 5.2 °C vs −43.0 ± 7.2 °C, p = 0.03). CB3 procedures were shorter (91.4 ± 21.7 vs 110.9 ± 31.8 min, p = 0.018), with a significant reduction in cryoenergy delivery time (24.2 ± 8.5 vs 20.3 ± 6.7 min, p < 0.05), and a significant reduction in left atrium dwell time (59.3 ± 9.8 vs 69.3 ± 10.8 min, p = 0.02, p < 0.05). At one year follow up period the Kaplan-Meier curve didn't show any significant difference in AF-free survival (Log p = 0,49). CONCLUSIONS: Novel CB3 is a useful tool in order to simplify AF cryoballoon ablation when compared to second generation cryoballoon, as observed in our experience. Follow up data seem confirm a clinical CB3 efficacy at least comparable CB2. |
format | Online Article Text |
id | pubmed-6090001 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-60900012018-08-16 Impact of the third generation cryoballoon on atrial fibrillation ablation: An useful tool? Sciarra, Luigi Iacopino, Saverio Palamà, Zefferino De Ruvo, Ermenegildo Filannino, Pasquale Borrelli, Alessio Artale, Paolo Caragliano, Alberto Scarà, Antonio Golia, Paolo De Luca, Lucia Grieco, Domenico Rebecchi, Marco Favale, Stefano Calò, Leonardo Indian Pacing Electrophysiol J Original Article BACKGROUND: Third-generation cryoballoon (CB3) is characterized by a 40% shorter distal tip designed to increase the rate of pulmonary veins real-time signal recording in order to measure time necessary to isolate veins, the “Time to effect” (TTE). Few data are currently available on clinical follow up of CB3 treated patients. METHODS: Sixtyeight consecutive patients (mean age 57.8 ± 9.6 years, 48 male) with paroxysmal or persistent atrial fibrillation (AF) were enrolled. Thirthyfour (25 paroxysmal AF) underwent to a 28 mmCB3 pulmonary veins isolation and were compared to 34 treated (21 paroxysmal AF) with 28 mmCB2. RESULTS: CB3 use was correlated to significant increase of the possibility to measure TTE in every treated veins (left superior 82,35% vs 23,53%, left inferior 70,59% vs 38,24%, right superior 58,82% vs 14,71%, right inferior 52,94% vs 17,65%). When it is measured, TTE wasn't different between two groups. Higher nadir temperature was observed in CB3 patients (−39.4 ± 5.2 °C vs −43.0 ± 7.2 °C, p = 0.03). CB3 procedures were shorter (91.4 ± 21.7 vs 110.9 ± 31.8 min, p = 0.018), with a significant reduction in cryoenergy delivery time (24.2 ± 8.5 vs 20.3 ± 6.7 min, p < 0.05), and a significant reduction in left atrium dwell time (59.3 ± 9.8 vs 69.3 ± 10.8 min, p = 0.02, p < 0.05). At one year follow up period the Kaplan-Meier curve didn't show any significant difference in AF-free survival (Log p = 0,49). CONCLUSIONS: Novel CB3 is a useful tool in order to simplify AF cryoballoon ablation when compared to second generation cryoballoon, as observed in our experience. Follow up data seem confirm a clinical CB3 efficacy at least comparable CB2. Elsevier 2018-02-22 /pmc/articles/PMC6090001/ /pubmed/29476904 http://dx.doi.org/10.1016/j.ipej.2018.02.003 Text en © 2018 Indian Heart Rhythm Society. Production and hosting by Elsevier B.V. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Original Article Sciarra, Luigi Iacopino, Saverio Palamà, Zefferino De Ruvo, Ermenegildo Filannino, Pasquale Borrelli, Alessio Artale, Paolo Caragliano, Alberto Scarà, Antonio Golia, Paolo De Luca, Lucia Grieco, Domenico Rebecchi, Marco Favale, Stefano Calò, Leonardo Impact of the third generation cryoballoon on atrial fibrillation ablation: An useful tool? |
title | Impact of the third generation cryoballoon on atrial fibrillation ablation: An useful tool? |
title_full | Impact of the third generation cryoballoon on atrial fibrillation ablation: An useful tool? |
title_fullStr | Impact of the third generation cryoballoon on atrial fibrillation ablation: An useful tool? |
title_full_unstemmed | Impact of the third generation cryoballoon on atrial fibrillation ablation: An useful tool? |
title_short | Impact of the third generation cryoballoon on atrial fibrillation ablation: An useful tool? |
title_sort | impact of the third generation cryoballoon on atrial fibrillation ablation: an useful tool? |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6090001/ https://www.ncbi.nlm.nih.gov/pubmed/29476904 http://dx.doi.org/10.1016/j.ipej.2018.02.003 |
work_keys_str_mv | AT sciarraluigi impactofthethirdgenerationcryoballoononatrialfibrillationablationanusefultool AT iacopinosaverio impactofthethirdgenerationcryoballoononatrialfibrillationablationanusefultool AT palamazefferino impactofthethirdgenerationcryoballoononatrialfibrillationablationanusefultool AT deruvoermenegildo impactofthethirdgenerationcryoballoononatrialfibrillationablationanusefultool AT filanninopasquale impactofthethirdgenerationcryoballoononatrialfibrillationablationanusefultool AT borrellialessio impactofthethirdgenerationcryoballoononatrialfibrillationablationanusefultool AT artalepaolo impactofthethirdgenerationcryoballoononatrialfibrillationablationanusefultool AT caraglianoalberto impactofthethirdgenerationcryoballoononatrialfibrillationablationanusefultool AT scaraantonio impactofthethirdgenerationcryoballoononatrialfibrillationablationanusefultool AT goliapaolo impactofthethirdgenerationcryoballoononatrialfibrillationablationanusefultool AT delucalucia impactofthethirdgenerationcryoballoononatrialfibrillationablationanusefultool AT griecodomenico impactofthethirdgenerationcryoballoononatrialfibrillationablationanusefultool AT rebecchimarco impactofthethirdgenerationcryoballoononatrialfibrillationablationanusefultool AT favalestefano impactofthethirdgenerationcryoballoononatrialfibrillationablationanusefultool AT caloleonardo impactofthethirdgenerationcryoballoononatrialfibrillationablationanusefultool |