Cargando…
Atrial electrogram quality in single-pass defibrillator leads with floating atrial bipole in patients with permanent atrial fibrillation and cardiac resynchronization therapy
Many patients receiving cardiac resynchronization therapy (CRT) suffer from permanent atrial fibrillation (AF). Knowledge of the atrial rhythm is important to direct pharmacological or interventional treatment as well as maintaining AV-synchronous biventricular pacing if sinus rhythm can be restored...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6090003/ https://www.ncbi.nlm.nih.gov/pubmed/29596906 http://dx.doi.org/10.1016/j.ipej.2018.03.005 |
_version_ | 1783347119334096896 |
---|---|
author | Sticherling, Christian Müller, Dirk Schaer, Beat A. Krüger, Silke Kolb, Christof |
author_facet | Sticherling, Christian Müller, Dirk Schaer, Beat A. Krüger, Silke Kolb, Christof |
author_sort | Sticherling, Christian |
collection | PubMed |
description | Many patients receiving cardiac resynchronization therapy (CRT) suffer from permanent atrial fibrillation (AF). Knowledge of the atrial rhythm is important to direct pharmacological or interventional treatment as well as maintaining AV-synchronous biventricular pacing if sinus rhythm can be restored. A single pass single-coil defibrillator lead with a floating atrial bipole has been shown to obtain reliable information about the atrial rhythm but has never been employed in a CRT-system. The purpose of this study was to assess the feasibility of implanting a single coil right ventricular ICD lead with a floating atrial bipole and the signal quality of atrial electrograms (AEGM) in CRT-defibrillator recipients with permanent AF. METHODS AND RESULTS: Seventeen patients (16 males, mean age 73 ± 6 years, mean EF 25 ± 5%) with permanent AF and an indication for CRT-defibrillator placement were implanted with a designated CRT-D system comprising a single pass defibrillator lead with a atrial floating bipole. They were followed-up for 103 ± 22 days using remote monitoring for AEGM transmission. All patients had at last one AEGM suitable for atrial rhythm diagnosis and of 100 AEGM 99% were suitable for visual atrial rhythm assessment. Four patients were discharged in sinus rhythm and one reverted to AF during follow-up. CONCLUSION: Atrial electrograms retrieved from a single-pass defibrillator lead with a floating atrial bipole can be reliably used for atrial rhythm diagnosis in CRT recipients with permanent AF. Hence, a single pass ventricular defibrillator lead with a floating bipole can be considered in this population. |
format | Online Article Text |
id | pubmed-6090003 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-60900032018-08-16 Atrial electrogram quality in single-pass defibrillator leads with floating atrial bipole in patients with permanent atrial fibrillation and cardiac resynchronization therapy Sticherling, Christian Müller, Dirk Schaer, Beat A. Krüger, Silke Kolb, Christof Indian Pacing Electrophysiol J Original Article Many patients receiving cardiac resynchronization therapy (CRT) suffer from permanent atrial fibrillation (AF). Knowledge of the atrial rhythm is important to direct pharmacological or interventional treatment as well as maintaining AV-synchronous biventricular pacing if sinus rhythm can be restored. A single pass single-coil defibrillator lead with a floating atrial bipole has been shown to obtain reliable information about the atrial rhythm but has never been employed in a CRT-system. The purpose of this study was to assess the feasibility of implanting a single coil right ventricular ICD lead with a floating atrial bipole and the signal quality of atrial electrograms (AEGM) in CRT-defibrillator recipients with permanent AF. METHODS AND RESULTS: Seventeen patients (16 males, mean age 73 ± 6 years, mean EF 25 ± 5%) with permanent AF and an indication for CRT-defibrillator placement were implanted with a designated CRT-D system comprising a single pass defibrillator lead with a atrial floating bipole. They were followed-up for 103 ± 22 days using remote monitoring for AEGM transmission. All patients had at last one AEGM suitable for atrial rhythm diagnosis and of 100 AEGM 99% were suitable for visual atrial rhythm assessment. Four patients were discharged in sinus rhythm and one reverted to AF during follow-up. CONCLUSION: Atrial electrograms retrieved from a single-pass defibrillator lead with a floating atrial bipole can be reliably used for atrial rhythm diagnosis in CRT recipients with permanent AF. Hence, a single pass ventricular defibrillator lead with a floating bipole can be considered in this population. Elsevier 2018-03-27 /pmc/articles/PMC6090003/ /pubmed/29596906 http://dx.doi.org/10.1016/j.ipej.2018.03.005 Text en © 2018 Indian Heart Rhythm Society. Production and hosting by Elsevier B.V. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Original Article Sticherling, Christian Müller, Dirk Schaer, Beat A. Krüger, Silke Kolb, Christof Atrial electrogram quality in single-pass defibrillator leads with floating atrial bipole in patients with permanent atrial fibrillation and cardiac resynchronization therapy |
title | Atrial electrogram quality in single-pass defibrillator leads with floating atrial bipole in patients with permanent atrial fibrillation and cardiac resynchronization therapy |
title_full | Atrial electrogram quality in single-pass defibrillator leads with floating atrial bipole in patients with permanent atrial fibrillation and cardiac resynchronization therapy |
title_fullStr | Atrial electrogram quality in single-pass defibrillator leads with floating atrial bipole in patients with permanent atrial fibrillation and cardiac resynchronization therapy |
title_full_unstemmed | Atrial electrogram quality in single-pass defibrillator leads with floating atrial bipole in patients with permanent atrial fibrillation and cardiac resynchronization therapy |
title_short | Atrial electrogram quality in single-pass defibrillator leads with floating atrial bipole in patients with permanent atrial fibrillation and cardiac resynchronization therapy |
title_sort | atrial electrogram quality in single-pass defibrillator leads with floating atrial bipole in patients with permanent atrial fibrillation and cardiac resynchronization therapy |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6090003/ https://www.ncbi.nlm.nih.gov/pubmed/29596906 http://dx.doi.org/10.1016/j.ipej.2018.03.005 |
work_keys_str_mv | AT sticherlingchristian atrialelectrogramqualityinsinglepassdefibrillatorleadswithfloatingatrialbipoleinpatientswithpermanentatrialfibrillationandcardiacresynchronizationtherapy AT mullerdirk atrialelectrogramqualityinsinglepassdefibrillatorleadswithfloatingatrialbipoleinpatientswithpermanentatrialfibrillationandcardiacresynchronizationtherapy AT schaerbeata atrialelectrogramqualityinsinglepassdefibrillatorleadswithfloatingatrialbipoleinpatientswithpermanentatrialfibrillationandcardiacresynchronizationtherapy AT krugersilke atrialelectrogramqualityinsinglepassdefibrillatorleadswithfloatingatrialbipoleinpatientswithpermanentatrialfibrillationandcardiacresynchronizationtherapy AT kolbchristof atrialelectrogramqualityinsinglepassdefibrillatorleadswithfloatingatrialbipoleinpatientswithpermanentatrialfibrillationandcardiacresynchronizationtherapy AT atrialelectrogramqualityinsinglepassdefibrillatorleadswithfloatingatrialbipoleinpatientswithpermanentatrialfibrillationandcardiacresynchronizationtherapy |