Cargando…

Atrial electrogram quality in single-pass defibrillator leads with floating atrial bipole in patients with permanent atrial fibrillation and cardiac resynchronization therapy

Many patients receiving cardiac resynchronization therapy (CRT) suffer from permanent atrial fibrillation (AF). Knowledge of the atrial rhythm is important to direct pharmacological or interventional treatment as well as maintaining AV-synchronous biventricular pacing if sinus rhythm can be restored...

Descripción completa

Detalles Bibliográficos
Autores principales: Sticherling, Christian, Müller, Dirk, Schaer, Beat A., Krüger, Silke, Kolb, Christof
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6090003/
https://www.ncbi.nlm.nih.gov/pubmed/29596906
http://dx.doi.org/10.1016/j.ipej.2018.03.005
_version_ 1783347119334096896
author Sticherling, Christian
Müller, Dirk
Schaer, Beat A.
Krüger, Silke
Kolb, Christof
author_facet Sticherling, Christian
Müller, Dirk
Schaer, Beat A.
Krüger, Silke
Kolb, Christof
author_sort Sticherling, Christian
collection PubMed
description Many patients receiving cardiac resynchronization therapy (CRT) suffer from permanent atrial fibrillation (AF). Knowledge of the atrial rhythm is important to direct pharmacological or interventional treatment as well as maintaining AV-synchronous biventricular pacing if sinus rhythm can be restored. A single pass single-coil defibrillator lead with a floating atrial bipole has been shown to obtain reliable information about the atrial rhythm but has never been employed in a CRT-system. The purpose of this study was to assess the feasibility of implanting a single coil right ventricular ICD lead with a floating atrial bipole and the signal quality of atrial electrograms (AEGM) in CRT-defibrillator recipients with permanent AF. METHODS AND RESULTS: Seventeen patients (16 males, mean age 73 ± 6 years, mean EF 25 ± 5%) with permanent AF and an indication for CRT-defibrillator placement were implanted with a designated CRT-D system comprising a single pass defibrillator lead with a atrial floating bipole. They were followed-up for 103 ± 22 days using remote monitoring for AEGM transmission. All patients had at last one AEGM suitable for atrial rhythm diagnosis and of 100 AEGM 99% were suitable for visual atrial rhythm assessment. Four patients were discharged in sinus rhythm and one reverted to AF during follow-up. CONCLUSION: Atrial electrograms retrieved from a single-pass defibrillator lead with a floating atrial bipole can be reliably used for atrial rhythm diagnosis in CRT recipients with permanent AF. Hence, a single pass ventricular defibrillator lead with a floating bipole can be considered in this population.
format Online
Article
Text
id pubmed-6090003
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-60900032018-08-16 Atrial electrogram quality in single-pass defibrillator leads with floating atrial bipole in patients with permanent atrial fibrillation and cardiac resynchronization therapy Sticherling, Christian Müller, Dirk Schaer, Beat A. Krüger, Silke Kolb, Christof Indian Pacing Electrophysiol J Original Article Many patients receiving cardiac resynchronization therapy (CRT) suffer from permanent atrial fibrillation (AF). Knowledge of the atrial rhythm is important to direct pharmacological or interventional treatment as well as maintaining AV-synchronous biventricular pacing if sinus rhythm can be restored. A single pass single-coil defibrillator lead with a floating atrial bipole has been shown to obtain reliable information about the atrial rhythm but has never been employed in a CRT-system. The purpose of this study was to assess the feasibility of implanting a single coil right ventricular ICD lead with a floating atrial bipole and the signal quality of atrial electrograms (AEGM) in CRT-defibrillator recipients with permanent AF. METHODS AND RESULTS: Seventeen patients (16 males, mean age 73 ± 6 years, mean EF 25 ± 5%) with permanent AF and an indication for CRT-defibrillator placement were implanted with a designated CRT-D system comprising a single pass defibrillator lead with a atrial floating bipole. They were followed-up for 103 ± 22 days using remote monitoring for AEGM transmission. All patients had at last one AEGM suitable for atrial rhythm diagnosis and of 100 AEGM 99% were suitable for visual atrial rhythm assessment. Four patients were discharged in sinus rhythm and one reverted to AF during follow-up. CONCLUSION: Atrial electrograms retrieved from a single-pass defibrillator lead with a floating atrial bipole can be reliably used for atrial rhythm diagnosis in CRT recipients with permanent AF. Hence, a single pass ventricular defibrillator lead with a floating bipole can be considered in this population. Elsevier 2018-03-27 /pmc/articles/PMC6090003/ /pubmed/29596906 http://dx.doi.org/10.1016/j.ipej.2018.03.005 Text en © 2018 Indian Heart Rhythm Society. Production and hosting by Elsevier B.V. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Article
Sticherling, Christian
Müller, Dirk
Schaer, Beat A.
Krüger, Silke
Kolb, Christof
Atrial electrogram quality in single-pass defibrillator leads with floating atrial bipole in patients with permanent atrial fibrillation and cardiac resynchronization therapy
title Atrial electrogram quality in single-pass defibrillator leads with floating atrial bipole in patients with permanent atrial fibrillation and cardiac resynchronization therapy
title_full Atrial electrogram quality in single-pass defibrillator leads with floating atrial bipole in patients with permanent atrial fibrillation and cardiac resynchronization therapy
title_fullStr Atrial electrogram quality in single-pass defibrillator leads with floating atrial bipole in patients with permanent atrial fibrillation and cardiac resynchronization therapy
title_full_unstemmed Atrial electrogram quality in single-pass defibrillator leads with floating atrial bipole in patients with permanent atrial fibrillation and cardiac resynchronization therapy
title_short Atrial electrogram quality in single-pass defibrillator leads with floating atrial bipole in patients with permanent atrial fibrillation and cardiac resynchronization therapy
title_sort atrial electrogram quality in single-pass defibrillator leads with floating atrial bipole in patients with permanent atrial fibrillation and cardiac resynchronization therapy
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6090003/
https://www.ncbi.nlm.nih.gov/pubmed/29596906
http://dx.doi.org/10.1016/j.ipej.2018.03.005
work_keys_str_mv AT sticherlingchristian atrialelectrogramqualityinsinglepassdefibrillatorleadswithfloatingatrialbipoleinpatientswithpermanentatrialfibrillationandcardiacresynchronizationtherapy
AT mullerdirk atrialelectrogramqualityinsinglepassdefibrillatorleadswithfloatingatrialbipoleinpatientswithpermanentatrialfibrillationandcardiacresynchronizationtherapy
AT schaerbeata atrialelectrogramqualityinsinglepassdefibrillatorleadswithfloatingatrialbipoleinpatientswithpermanentatrialfibrillationandcardiacresynchronizationtherapy
AT krugersilke atrialelectrogramqualityinsinglepassdefibrillatorleadswithfloatingatrialbipoleinpatientswithpermanentatrialfibrillationandcardiacresynchronizationtherapy
AT kolbchristof atrialelectrogramqualityinsinglepassdefibrillatorleadswithfloatingatrialbipoleinpatientswithpermanentatrialfibrillationandcardiacresynchronizationtherapy
AT atrialelectrogramqualityinsinglepassdefibrillatorleadswithfloatingatrialbipoleinpatientswithpermanentatrialfibrillationandcardiacresynchronizationtherapy