Cargando…

Standard and optimal cut-off values of serum ca-125, HE4 and ROMA in preoperative prediction of ovarian cancer in Vietnam

OBJECTIVES: To evaluate the validity of serum CA-125, Human Epididymis protein 4 (HE4) and Risk of Malignancy Algorithm (ROMA) at standard and optimal cut-offs, in preoperative prediction of epithelial ovarian carcinoma (EOC) in Vietnam. SUBJECTS AND METHODS: Cross-sectional, descriptive study on 27...

Descripción completa

Detalles Bibliográficos
Autores principales: Huy, Nguyen Vu Quoc, Van Khoa, Vo, Tam, Le Minh, Vinh, Truong Quang, Tung, Nguyen Sanh, Thanh, Cao Ngoc, Chuang, Linus
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6090087/
https://www.ncbi.nlm.nih.gov/pubmed/30109256
http://dx.doi.org/10.1016/j.gore.2018.07.002
_version_ 1783347139430055936
author Huy, Nguyen Vu Quoc
Van Khoa, Vo
Tam, Le Minh
Vinh, Truong Quang
Tung, Nguyen Sanh
Thanh, Cao Ngoc
Chuang, Linus
author_facet Huy, Nguyen Vu Quoc
Van Khoa, Vo
Tam, Le Minh
Vinh, Truong Quang
Tung, Nguyen Sanh
Thanh, Cao Ngoc
Chuang, Linus
author_sort Huy, Nguyen Vu Quoc
collection PubMed
description OBJECTIVES: To evaluate the validity of serum CA-125, Human Epididymis protein 4 (HE4) and Risk of Malignancy Algorithm (ROMA) at standard and optimal cut-offs, in preoperative prediction of epithelial ovarian carcinoma (EOC) in Vietnam. SUBJECTS AND METHODS: Cross-sectional, descriptive study on 277 patients with ovarian masses hospitalized at the OBGYN Departments, Hue University Hospital and Hue Central Hospital, Vietnam, from 01/2016 to 11/2017. All patients had measurements of serum CA-125 by Elecsys 2010 system and HE4 by immunoassay ARCHITECT® HE4 kits; ROMA calculated, and preoperative malignancy risk estimated. Matching these values to postoperative histopathology resulted in the preoperative prediction values. RESULTS: There were 30 (10.8%) cases of EOC. Median values of CA 125, HE4, and ROMA of EOC and benign tumors were 214.20 U/ml, 18.91 U/ml; 90.00 pmol/l, 39.80 pmol/l; and 55.20%, 4.80%, respectively. The sensitivities and specificity of CA125, HE4, and ROMA to distinguish between malignant and benign tumors at standard cut-offs were 83.3% and 78.5%; 50% and 98.38%; 80.0% and 84,6%, and those at optimal cut-offs were 83.3% and 86.6%; 80.0% and 91.5%, 86.7% and 88.7%, respectively. AUCs of CA-125, HE4, and ROMA were 0.872, 0.894, 0.912; and those for the post-menopausal group were 0.900, 0.894 and 0.924, respectively. CONCLUSION: Serum CA 125 and HE4 levels and ROMA have good validity in the diagnosis of EOC, of which ROMA gives the best result. The ROMA index should be applied in clinical practice to help in the assessment and management of patients with suspected ovarian cancer.
format Online
Article
Text
id pubmed-6090087
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-60900872018-08-14 Standard and optimal cut-off values of serum ca-125, HE4 and ROMA in preoperative prediction of ovarian cancer in Vietnam Huy, Nguyen Vu Quoc Van Khoa, Vo Tam, Le Minh Vinh, Truong Quang Tung, Nguyen Sanh Thanh, Cao Ngoc Chuang, Linus Gynecol Oncol Rep Special Section on Gynecologic Cancers in Resource-constrained Countries; Edited by Linus Chuang and Thomas Randall OBJECTIVES: To evaluate the validity of serum CA-125, Human Epididymis protein 4 (HE4) and Risk of Malignancy Algorithm (ROMA) at standard and optimal cut-offs, in preoperative prediction of epithelial ovarian carcinoma (EOC) in Vietnam. SUBJECTS AND METHODS: Cross-sectional, descriptive study on 277 patients with ovarian masses hospitalized at the OBGYN Departments, Hue University Hospital and Hue Central Hospital, Vietnam, from 01/2016 to 11/2017. All patients had measurements of serum CA-125 by Elecsys 2010 system and HE4 by immunoassay ARCHITECT® HE4 kits; ROMA calculated, and preoperative malignancy risk estimated. Matching these values to postoperative histopathology resulted in the preoperative prediction values. RESULTS: There were 30 (10.8%) cases of EOC. Median values of CA 125, HE4, and ROMA of EOC and benign tumors were 214.20 U/ml, 18.91 U/ml; 90.00 pmol/l, 39.80 pmol/l; and 55.20%, 4.80%, respectively. The sensitivities and specificity of CA125, HE4, and ROMA to distinguish between malignant and benign tumors at standard cut-offs were 83.3% and 78.5%; 50% and 98.38%; 80.0% and 84,6%, and those at optimal cut-offs were 83.3% and 86.6%; 80.0% and 91.5%, 86.7% and 88.7%, respectively. AUCs of CA-125, HE4, and ROMA were 0.872, 0.894, 0.912; and those for the post-menopausal group were 0.900, 0.894 and 0.924, respectively. CONCLUSION: Serum CA 125 and HE4 levels and ROMA have good validity in the diagnosis of EOC, of which ROMA gives the best result. The ROMA index should be applied in clinical practice to help in the assessment and management of patients with suspected ovarian cancer. Elsevier 2018-07-18 /pmc/articles/PMC6090087/ /pubmed/30109256 http://dx.doi.org/10.1016/j.gore.2018.07.002 Text en © 2018 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Special Section on Gynecologic Cancers in Resource-constrained Countries; Edited by Linus Chuang and Thomas Randall
Huy, Nguyen Vu Quoc
Van Khoa, Vo
Tam, Le Minh
Vinh, Truong Quang
Tung, Nguyen Sanh
Thanh, Cao Ngoc
Chuang, Linus
Standard and optimal cut-off values of serum ca-125, HE4 and ROMA in preoperative prediction of ovarian cancer in Vietnam
title Standard and optimal cut-off values of serum ca-125, HE4 and ROMA in preoperative prediction of ovarian cancer in Vietnam
title_full Standard and optimal cut-off values of serum ca-125, HE4 and ROMA in preoperative prediction of ovarian cancer in Vietnam
title_fullStr Standard and optimal cut-off values of serum ca-125, HE4 and ROMA in preoperative prediction of ovarian cancer in Vietnam
title_full_unstemmed Standard and optimal cut-off values of serum ca-125, HE4 and ROMA in preoperative prediction of ovarian cancer in Vietnam
title_short Standard and optimal cut-off values of serum ca-125, HE4 and ROMA in preoperative prediction of ovarian cancer in Vietnam
title_sort standard and optimal cut-off values of serum ca-125, he4 and roma in preoperative prediction of ovarian cancer in vietnam
topic Special Section on Gynecologic Cancers in Resource-constrained Countries; Edited by Linus Chuang and Thomas Randall
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6090087/
https://www.ncbi.nlm.nih.gov/pubmed/30109256
http://dx.doi.org/10.1016/j.gore.2018.07.002
work_keys_str_mv AT huynguyenvuquoc standardandoptimalcutoffvaluesofserumca125he4andromainpreoperativepredictionofovariancancerinvietnam
AT vankhoavo standardandoptimalcutoffvaluesofserumca125he4andromainpreoperativepredictionofovariancancerinvietnam
AT tamleminh standardandoptimalcutoffvaluesofserumca125he4andromainpreoperativepredictionofovariancancerinvietnam
AT vinhtruongquang standardandoptimalcutoffvaluesofserumca125he4andromainpreoperativepredictionofovariancancerinvietnam
AT tungnguyensanh standardandoptimalcutoffvaluesofserumca125he4andromainpreoperativepredictionofovariancancerinvietnam
AT thanhcaongoc standardandoptimalcutoffvaluesofserumca125he4andromainpreoperativepredictionofovariancancerinvietnam
AT chuanglinus standardandoptimalcutoffvaluesofserumca125he4andromainpreoperativepredictionofovariancancerinvietnam