A Novel 12-Lead Electrocardiographic System for Home Use: Development and Usability Testing

BACKGROUND: Cardiovascular diseases (CVD) are the leading cause of morbidity and mortality worldwide. Early diagnosis is of pivotal importance for patients with cardiac arrhythmias and ischemia to minimize the consequences like strokes and myocardial infarctions. The chance of capturing signals of a...

Descripción completa

Detalles Bibliográficos
Autores principales: Steijlen, Annemarijn SM, Jansen, Kaspar MB, Albayrak, Armagan, Verschure, Derk O, Van Wijk, Diederik F
Formato: Online Artículo Texto
Lenguaje:English
Publicado: JMIR Publications 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6090173/
https://www.ncbi.nlm.nih.gov/pubmed/30061094
http://dx.doi.org/10.2196/10126
_version_ 1783347150358315008
author Steijlen, Annemarijn SM
Jansen, Kaspar MB
Albayrak, Armagan
Verschure, Derk O
Van Wijk, Diederik F
author_facet Steijlen, Annemarijn SM
Jansen, Kaspar MB
Albayrak, Armagan
Verschure, Derk O
Van Wijk, Diederik F
author_sort Steijlen, Annemarijn SM
collection PubMed
description BACKGROUND: Cardiovascular diseases (CVD) are the leading cause of morbidity and mortality worldwide. Early diagnosis is of pivotal importance for patients with cardiac arrhythmias and ischemia to minimize the consequences like strokes and myocardial infarctions. The chance of capturing signals of arrhythmias or ischemia is substantially high when a 12-lead electrocardiogram (ECG) can be recorded at the moment when a patient experiences the symptoms. However, until now, available diagnostic systems (Holter monitors and other wearable ECG sensors) have not enabled patients to record a reliable 12-lead ECG at home. OBJECTIVE: The objective of this project was to develop a user-friendly system that enables persons with cardiac complaints to record a reliable 12-lead ECG at home to improve the diagnostic process and, consequently, reduce the time between the onset of symptoms and adequate treatment. METHODS: Using an iterative design approach, ECGraph was developed. The system consists of an ECG measurement system and a mobile app, which were developed with the help of several concept tests. To evaluate the design, a prototype of the final design was built and a final technical performance test and usability test were executed. RESULTS: The ECG measurement system consists of a belt and 4 limb straps. Ten wet Ag/AgCl electrodes are placed in the belt to optimize skin-electrode contact. The product is controlled via an app on the mobile phone of the user. Once a person experiences symptoms, he or she can put on the belt and record ECGs within a few minutes. Short instructions, supported by visualizations, offer guidance during use. ECGs are sent wirelessly to the caregiver, and the designated expert can quickly interpret the results. Usability tests with the final prototype (n=6) showed that the participants were able to put on the product within 8 minutes during first-time use. However, we expect that the placement of the product can be executed faster when the user becomes more familiar with the product. Areas of improvement focus mainly on confidence during product use. In the technical performance test, a 12-lead ECG was made and reproduced 6 times. CONCLUSIONS: We developed a new 12-lead ECG system for home use. The product is expected to be more user-friendly than current hospital ECG systems and is designed to record more reliable data than current ECG systems for home use, which makes it suitable for expert interpretation. The system has great potential to be incorporated into an outpatient practice, so that arrhythmias and ischemia can be diagnosed and treated as early as possible.
format Online
Article
Text
id pubmed-6090173
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher JMIR Publications
record_format MEDLINE/PubMed
spelling pubmed-60901732018-08-21 A Novel 12-Lead Electrocardiographic System for Home Use: Development and Usability Testing Steijlen, Annemarijn SM Jansen, Kaspar MB Albayrak, Armagan Verschure, Derk O Van Wijk, Diederik F JMIR Mhealth Uhealth Original Paper BACKGROUND: Cardiovascular diseases (CVD) are the leading cause of morbidity and mortality worldwide. Early diagnosis is of pivotal importance for patients with cardiac arrhythmias and ischemia to minimize the consequences like strokes and myocardial infarctions. The chance of capturing signals of arrhythmias or ischemia is substantially high when a 12-lead electrocardiogram (ECG) can be recorded at the moment when a patient experiences the symptoms. However, until now, available diagnostic systems (Holter monitors and other wearable ECG sensors) have not enabled patients to record a reliable 12-lead ECG at home. OBJECTIVE: The objective of this project was to develop a user-friendly system that enables persons with cardiac complaints to record a reliable 12-lead ECG at home to improve the diagnostic process and, consequently, reduce the time between the onset of symptoms and adequate treatment. METHODS: Using an iterative design approach, ECGraph was developed. The system consists of an ECG measurement system and a mobile app, which were developed with the help of several concept tests. To evaluate the design, a prototype of the final design was built and a final technical performance test and usability test were executed. RESULTS: The ECG measurement system consists of a belt and 4 limb straps. Ten wet Ag/AgCl electrodes are placed in the belt to optimize skin-electrode contact. The product is controlled via an app on the mobile phone of the user. Once a person experiences symptoms, he or she can put on the belt and record ECGs within a few minutes. Short instructions, supported by visualizations, offer guidance during use. ECGs are sent wirelessly to the caregiver, and the designated expert can quickly interpret the results. Usability tests with the final prototype (n=6) showed that the participants were able to put on the product within 8 minutes during first-time use. However, we expect that the placement of the product can be executed faster when the user becomes more familiar with the product. Areas of improvement focus mainly on confidence during product use. In the technical performance test, a 12-lead ECG was made and reproduced 6 times. CONCLUSIONS: We developed a new 12-lead ECG system for home use. The product is expected to be more user-friendly than current hospital ECG systems and is designed to record more reliable data than current ECG systems for home use, which makes it suitable for expert interpretation. The system has great potential to be incorporated into an outpatient practice, so that arrhythmias and ischemia can be diagnosed and treated as early as possible. JMIR Publications 2018-07-30 /pmc/articles/PMC6090173/ /pubmed/30061094 http://dx.doi.org/10.2196/10126 Text en ©Annemarijn SM Steijlen, Kaspar MB Jansen, Armagan Albayrak, Derk O Verschure, Diederik F Van Wijk. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 30.07.2018. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR mhealth and uhealth, is properly cited. The complete bibliographic information, a link to the original publication on http://mhealth.jmir.org/, as well as this copyright and license information must be included.
spellingShingle Original Paper
Steijlen, Annemarijn SM
Jansen, Kaspar MB
Albayrak, Armagan
Verschure, Derk O
Van Wijk, Diederik F
A Novel 12-Lead Electrocardiographic System for Home Use: Development and Usability Testing
title A Novel 12-Lead Electrocardiographic System for Home Use: Development and Usability Testing
title_full A Novel 12-Lead Electrocardiographic System for Home Use: Development and Usability Testing
title_fullStr A Novel 12-Lead Electrocardiographic System for Home Use: Development and Usability Testing
title_full_unstemmed A Novel 12-Lead Electrocardiographic System for Home Use: Development and Usability Testing
title_short A Novel 12-Lead Electrocardiographic System for Home Use: Development and Usability Testing
title_sort novel 12-lead electrocardiographic system for home use: development and usability testing
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6090173/
https://www.ncbi.nlm.nih.gov/pubmed/30061094
http://dx.doi.org/10.2196/10126
work_keys_str_mv AT steijlenannemarijnsm anovel12leadelectrocardiographicsystemforhomeusedevelopmentandusabilitytesting
AT jansenkasparmb anovel12leadelectrocardiographicsystemforhomeusedevelopmentandusabilitytesting
AT albayrakarmagan anovel12leadelectrocardiographicsystemforhomeusedevelopmentandusabilitytesting
AT verschurederko anovel12leadelectrocardiographicsystemforhomeusedevelopmentandusabilitytesting
AT vanwijkdiederikf anovel12leadelectrocardiographicsystemforhomeusedevelopmentandusabilitytesting
AT steijlenannemarijnsm novel12leadelectrocardiographicsystemforhomeusedevelopmentandusabilitytesting
AT jansenkasparmb novel12leadelectrocardiographicsystemforhomeusedevelopmentandusabilitytesting
AT albayrakarmagan novel12leadelectrocardiographicsystemforhomeusedevelopmentandusabilitytesting
AT verschurederko novel12leadelectrocardiographicsystemforhomeusedevelopmentandusabilitytesting
AT vanwijkdiederikf novel12leadelectrocardiographicsystemforhomeusedevelopmentandusabilitytesting