Cargando…

Radial probe endobronchial ultrasound using a guide sheath for peripheral lung lesions in beginners

BACKGROUND: The diagnostic yields and safety profiles of transbronchial lung biopsy have not been evaluated in inexperienced physicians using the combined modality of radial probe endobronchial ultrasound and a guide sheath (EBUS-GS). This study assessed the utility and safety of EBUS-GS during the...

Descripción completa

Detalles Bibliográficos
Autores principales: Eom, Jung Seop, Mok, Jeong Ha, Kim, Insu, Lee, Min Ki, Lee, Geewon, Park, Hyemi, Lee, Ji Won, Jeong, Yeon Joo, Kim, Won-Young, Jo, Eun Jung, Kim, Mi Hyun, Lee, Kwangha, Kim, Ki Uk, Park, Hye-Kyung
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6090614/
https://www.ncbi.nlm.nih.gov/pubmed/30103727
http://dx.doi.org/10.1186/s12890-018-0704-7
Descripción
Sumario:BACKGROUND: The diagnostic yields and safety profiles of transbronchial lung biopsy have not been evaluated in inexperienced physicians using the combined modality of radial probe endobronchial ultrasound and a guide sheath (EBUS-GS). This study assessed the utility and safety of EBUS-GS during the learning phase by referring to a database of performed EBUS-GS procedures. METHODS: From December 2015 to January 2017, all of the consecutive patients who underwent EBUS-GS were registered. During the study period, two physicians with no previous experience performed the procedure. To assess the diagnostic yields, learning curve, and safety profile of EBUS-GS performed by these inexperienced physicians, the first 100 consecutive EBUS-GS procedures were included in the evaluation. RESULTS: The overall diagnostic yield of EBUS-GS performed by two physicans in 200 patients with a peripheral lung lesion was 73.0%. Learning curve analyses showed that the diagnostic yields were stable, even when the procedure was performed by beginners. Complications related to EBUS-GS occurred in three patients (1.5%): pneumothorax developed in two patients (1%) and resolved spontaneously without chest tube drainage; another patient (0.5%) developed a pulmonary infection after EBUS-GS. There were no cases of pneumothorax requiring chest tube drainage, severe hemorrhage, respiratory failure, premature termination of the procedure, or procedure-related mortality. CONCLUSIONS: EBUS-GS is a safe and stable procedure with an acceptable diagnostic yield, even when performed by physicians with no previous experience. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s12890-018-0704-7) contains supplementary material, which is available to authorized users.