Cargando…

Improving accuracy of corneal power measurement with partial coherence interferometry after corneal refractive surgery using a multivariate polynomial approach

BACKGROUND: To improve accuracy of IOLMaster (Carl Zeiss, Jena, Germany) in corneal power measurement after myopic excimer corneal refractive surgery (MECRS) using multivariate polynomial analysis (MPA). METHODS: One eye of each of 403 patients (mean age 31.53 ± 8.47 years) was subjected to MECRS fo...

Descripción completa

Detalles Bibliográficos
Autores principales: Lanza, Michele, Koprowski, Robert, Bifani Sconocchia, Mario
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6090680/
https://www.ncbi.nlm.nih.gov/pubmed/30103748
http://dx.doi.org/10.1186/s12938-018-0542-0
_version_ 1783347234126954496
author Lanza, Michele
Koprowski, Robert
Bifani Sconocchia, Mario
author_facet Lanza, Michele
Koprowski, Robert
Bifani Sconocchia, Mario
author_sort Lanza, Michele
collection PubMed
description BACKGROUND: To improve accuracy of IOLMaster (Carl Zeiss, Jena, Germany) in corneal power measurement after myopic excimer corneal refractive surgery (MECRS) using multivariate polynomial analysis (MPA). METHODS: One eye of each of 403 patients (mean age 31.53 ± 8.47 years) was subjected to MECRS for a myopic defect, measured as spherical equivalent, ranging from − 9.50 to − 1 D (mean − 4.55 ± 2.20 D). Each patient underwent a complete eye examination and IOLMaster scan before surgery and at 1, 3 and 6 months follow up. Axial length (AL), flatter keratometry value (K1), steeper keratometry value (K2), mean keratometry value (KM) and anterior chamber depth measured from the corneal endothelium to the anterior surface of the lens (ACD) were used in a MPA to devise a method to improve accuracy of KM measurements. RESULTS: Using AL, K1, K2 and ACD measured after surgery in polynomial degree 2 analysis, mean error of corneal power evaluation after MECRS was + 0.16 ± 0.19 D. CONCLUSIONS: MPA was found to be an effective tool in devising a method to improve precision in corneal power evaluation in eyes previously subjected to MECRS, according to our results.
format Online
Article
Text
id pubmed-6090680
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-60906802018-08-17 Improving accuracy of corneal power measurement with partial coherence interferometry after corneal refractive surgery using a multivariate polynomial approach Lanza, Michele Koprowski, Robert Bifani Sconocchia, Mario Biomed Eng Online Research BACKGROUND: To improve accuracy of IOLMaster (Carl Zeiss, Jena, Germany) in corneal power measurement after myopic excimer corneal refractive surgery (MECRS) using multivariate polynomial analysis (MPA). METHODS: One eye of each of 403 patients (mean age 31.53 ± 8.47 years) was subjected to MECRS for a myopic defect, measured as spherical equivalent, ranging from − 9.50 to − 1 D (mean − 4.55 ± 2.20 D). Each patient underwent a complete eye examination and IOLMaster scan before surgery and at 1, 3 and 6 months follow up. Axial length (AL), flatter keratometry value (K1), steeper keratometry value (K2), mean keratometry value (KM) and anterior chamber depth measured from the corneal endothelium to the anterior surface of the lens (ACD) were used in a MPA to devise a method to improve accuracy of KM measurements. RESULTS: Using AL, K1, K2 and ACD measured after surgery in polynomial degree 2 analysis, mean error of corneal power evaluation after MECRS was + 0.16 ± 0.19 D. CONCLUSIONS: MPA was found to be an effective tool in devising a method to improve precision in corneal power evaluation in eyes previously subjected to MECRS, according to our results. BioMed Central 2018-08-13 /pmc/articles/PMC6090680/ /pubmed/30103748 http://dx.doi.org/10.1186/s12938-018-0542-0 Text en © The Author(s) 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Lanza, Michele
Koprowski, Robert
Bifani Sconocchia, Mario
Improving accuracy of corneal power measurement with partial coherence interferometry after corneal refractive surgery using a multivariate polynomial approach
title Improving accuracy of corneal power measurement with partial coherence interferometry after corneal refractive surgery using a multivariate polynomial approach
title_full Improving accuracy of corneal power measurement with partial coherence interferometry after corneal refractive surgery using a multivariate polynomial approach
title_fullStr Improving accuracy of corneal power measurement with partial coherence interferometry after corneal refractive surgery using a multivariate polynomial approach
title_full_unstemmed Improving accuracy of corneal power measurement with partial coherence interferometry after corneal refractive surgery using a multivariate polynomial approach
title_short Improving accuracy of corneal power measurement with partial coherence interferometry after corneal refractive surgery using a multivariate polynomial approach
title_sort improving accuracy of corneal power measurement with partial coherence interferometry after corneal refractive surgery using a multivariate polynomial approach
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6090680/
https://www.ncbi.nlm.nih.gov/pubmed/30103748
http://dx.doi.org/10.1186/s12938-018-0542-0
work_keys_str_mv AT lanzamichele improvingaccuracyofcornealpowermeasurementwithpartialcoherenceinterferometryaftercornealrefractivesurgeryusingamultivariatepolynomialapproach
AT koprowskirobert improvingaccuracyofcornealpowermeasurementwithpartialcoherenceinterferometryaftercornealrefractivesurgeryusingamultivariatepolynomialapproach
AT bifanisconocchiamario improvingaccuracyofcornealpowermeasurementwithpartialcoherenceinterferometryaftercornealrefractivesurgeryusingamultivariatepolynomialapproach