Cargando…
Finite Element Analysis of Different Double-Plate Angles in the Treatment of the Femoral Shaft Nonunion with No Cortical Support opposite the Primary Lateral Plate
OBJECTIVES: We evaluated the biomechanical outcome of different plate fixation strategies (the single plate construct, 45° double-plate construct, 90° double-plate construct, 135° double-plate construct, and 180° double-plate construct) used for the fixation of the femoral shaft nonunion with no cor...
Autores principales: | Zhang, Hao, Li, Jiantao, Zhou, Jianfeng, Li, Lianting, Hao, Ming, Wang, Kun, Xu, Gaoxiang, Li, Chen, Zhang, Wei, Tang, Peifu |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6091371/ https://www.ncbi.nlm.nih.gov/pubmed/30151378 http://dx.doi.org/10.1155/2018/3267107 |
Ejemplares similares
-
Clinical outcomes of femoral shaft non-union: dual plating versus exchange nailing with augmentation plating
por: Zhang, Wei, et al.
Publicado: (2018) -
Sliding bone graft combined with double locking plate fixation for the treatment of femoral shaft nonunion
por: Xing, Wenzhao, et al.
Publicado: (2019) -
Outcome of locking compression plates in humeral shaft nonunions
por: Biraris, Sandeep R, et al.
Publicado: (2013) -
Outcome of locking compression plates in humeral shaft nonunions
por: Kumar, Malhar N, et al.
Publicado: (2013) -
The comparison of single plate and double plate fixation methods for treatment of humeral shaft nonunions
por: Tecimel, Osman, et al.
Publicado: (2021)