Cargando…

Computed tomography image quality of aortic stents in patients with aortic coarctation: a multicentre evaluation

BACKGROUND: Stents are commonly used to treat aortic coarctation. The objective of this study was to evaluate the post-implantation computed tomography (CT) image quality of different stent types used to treat aortic coarctation. METHODS: Adult and paediatric patients with stent-treated aortic coarc...

Descripción completa

Detalles Bibliográficos
Autores principales: Boccalini, Sara, den Harder, Annemarie M., Witsenburg, Maarten, Breur, Johannes P. J. M., Krestin, Gabriel P., van Beynum, Ingrid M., Attrach, Mohamed, Stagnaro, Nicola, Marasini, Maurizio, de Jong, Pim A., Leiner, Tim, Budde, Ricardo P. J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6091724/
https://www.ncbi.nlm.nih.gov/pubmed/33252748
http://dx.doi.org/10.1186/s41747-018-0046-5
_version_ 1783347418649067520
author Boccalini, Sara
den Harder, Annemarie M.
Witsenburg, Maarten
Breur, Johannes P. J. M.
Krestin, Gabriel P.
van Beynum, Ingrid M.
Attrach, Mohamed
Stagnaro, Nicola
Marasini, Maurizio
de Jong, Pim A.
Leiner, Tim
Budde, Ricardo P. J.
author_facet Boccalini, Sara
den Harder, Annemarie M.
Witsenburg, Maarten
Breur, Johannes P. J. M.
Krestin, Gabriel P.
van Beynum, Ingrid M.
Attrach, Mohamed
Stagnaro, Nicola
Marasini, Maurizio
de Jong, Pim A.
Leiner, Tim
Budde, Ricardo P. J.
author_sort Boccalini, Sara
collection PubMed
description BACKGROUND: Stents are commonly used to treat aortic coarctation. The objective of this study was to evaluate the post-implantation computed tomography (CT) image quality of different stent types used to treat aortic coarctation. METHODS: Adult and paediatric patients with stent-treated aortic coarctation who underwent contrast-enhanced CT were retrospectively included from three tertiary care centres. CT scans were subjectively scored for image quality using a 4-point scale (1 = unacceptable; 2 = poor; 3 = good; 4 = excellent). Furthermore, the amount of stent-induced blooming artefacts was measured as the percentage of the difference between outer and inner stent diameters over the outer stent diameter. RESULTS: A total of 35 children and 34 adults implanted with 71 stents of six different types were included. The most commonly used stent type was the Cheatham Platinum stent (52 stents, 73%). The subjective image quality of the Cheatham Platinum stents was moderate with a score of 2.0±0.8 (mean ± standard deviation) in children and 2.3±0.6 in adults. The image quality in patients with Formula stents was 2.3±1.2. The Cheatham Platinum stents induced 34–48% blooming, the Formula stents 44–55%. The image quality in patients with the less commonly used Atrium Advanta V12, IntraStent, AndraStent and Palmaz stents was scored 3 (good) to 4 (excellent) with less blooming. The electrocardiographic gating and tube voltage (kVp) did not affect image quality. CONCLUSIONS: There is a substantial variation in CT image quality and blooming artefacts for different stent types used to treat aortic coarctation.
format Online
Article
Text
id pubmed-6091724
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-60917242018-09-27 Computed tomography image quality of aortic stents in patients with aortic coarctation: a multicentre evaluation Boccalini, Sara den Harder, Annemarie M. Witsenburg, Maarten Breur, Johannes P. J. M. Krestin, Gabriel P. van Beynum, Ingrid M. Attrach, Mohamed Stagnaro, Nicola Marasini, Maurizio de Jong, Pim A. Leiner, Tim Budde, Ricardo P. J. Eur Radiol Exp Original Article BACKGROUND: Stents are commonly used to treat aortic coarctation. The objective of this study was to evaluate the post-implantation computed tomography (CT) image quality of different stent types used to treat aortic coarctation. METHODS: Adult and paediatric patients with stent-treated aortic coarctation who underwent contrast-enhanced CT were retrospectively included from three tertiary care centres. CT scans were subjectively scored for image quality using a 4-point scale (1 = unacceptable; 2 = poor; 3 = good; 4 = excellent). Furthermore, the amount of stent-induced blooming artefacts was measured as the percentage of the difference between outer and inner stent diameters over the outer stent diameter. RESULTS: A total of 35 children and 34 adults implanted with 71 stents of six different types were included. The most commonly used stent type was the Cheatham Platinum stent (52 stents, 73%). The subjective image quality of the Cheatham Platinum stents was moderate with a score of 2.0±0.8 (mean ± standard deviation) in children and 2.3±0.6 in adults. The image quality in patients with Formula stents was 2.3±1.2. The Cheatham Platinum stents induced 34–48% blooming, the Formula stents 44–55%. The image quality in patients with the less commonly used Atrium Advanta V12, IntraStent, AndraStent and Palmaz stents was scored 3 (good) to 4 (excellent) with less blooming. The electrocardiographic gating and tube voltage (kVp) did not affect image quality. CONCLUSIONS: There is a substantial variation in CT image quality and blooming artefacts for different stent types used to treat aortic coarctation. Springer International Publishing 2018-07-18 /pmc/articles/PMC6091724/ /pubmed/33252748 http://dx.doi.org/10.1186/s41747-018-0046-5 Text en © The Author(s) 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Original Article
Boccalini, Sara
den Harder, Annemarie M.
Witsenburg, Maarten
Breur, Johannes P. J. M.
Krestin, Gabriel P.
van Beynum, Ingrid M.
Attrach, Mohamed
Stagnaro, Nicola
Marasini, Maurizio
de Jong, Pim A.
Leiner, Tim
Budde, Ricardo P. J.
Computed tomography image quality of aortic stents in patients with aortic coarctation: a multicentre evaluation
title Computed tomography image quality of aortic stents in patients with aortic coarctation: a multicentre evaluation
title_full Computed tomography image quality of aortic stents in patients with aortic coarctation: a multicentre evaluation
title_fullStr Computed tomography image quality of aortic stents in patients with aortic coarctation: a multicentre evaluation
title_full_unstemmed Computed tomography image quality of aortic stents in patients with aortic coarctation: a multicentre evaluation
title_short Computed tomography image quality of aortic stents in patients with aortic coarctation: a multicentre evaluation
title_sort computed tomography image quality of aortic stents in patients with aortic coarctation: a multicentre evaluation
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6091724/
https://www.ncbi.nlm.nih.gov/pubmed/33252748
http://dx.doi.org/10.1186/s41747-018-0046-5
work_keys_str_mv AT boccalinisara computedtomographyimagequalityofaorticstentsinpatientswithaorticcoarctationamulticentreevaluation
AT denharderannemariem computedtomographyimagequalityofaorticstentsinpatientswithaorticcoarctationamulticentreevaluation
AT witsenburgmaarten computedtomographyimagequalityofaorticstentsinpatientswithaorticcoarctationamulticentreevaluation
AT breurjohannespjm computedtomographyimagequalityofaorticstentsinpatientswithaorticcoarctationamulticentreevaluation
AT krestingabrielp computedtomographyimagequalityofaorticstentsinpatientswithaorticcoarctationamulticentreevaluation
AT vanbeynumingridm computedtomographyimagequalityofaorticstentsinpatientswithaorticcoarctationamulticentreevaluation
AT attrachmohamed computedtomographyimagequalityofaorticstentsinpatientswithaorticcoarctationamulticentreevaluation
AT stagnaronicola computedtomographyimagequalityofaorticstentsinpatientswithaorticcoarctationamulticentreevaluation
AT marasinimaurizio computedtomographyimagequalityofaorticstentsinpatientswithaorticcoarctationamulticentreevaluation
AT dejongpima computedtomographyimagequalityofaorticstentsinpatientswithaorticcoarctationamulticentreevaluation
AT leinertim computedtomographyimagequalityofaorticstentsinpatientswithaorticcoarctationamulticentreevaluation
AT buddericardopj computedtomographyimagequalityofaorticstentsinpatientswithaorticcoarctationamulticentreevaluation