Cargando…
Computed tomography image quality of aortic stents in patients with aortic coarctation: a multicentre evaluation
BACKGROUND: Stents are commonly used to treat aortic coarctation. The objective of this study was to evaluate the post-implantation computed tomography (CT) image quality of different stent types used to treat aortic coarctation. METHODS: Adult and paediatric patients with stent-treated aortic coarc...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6091724/ https://www.ncbi.nlm.nih.gov/pubmed/33252748 http://dx.doi.org/10.1186/s41747-018-0046-5 |
_version_ | 1783347418649067520 |
---|---|
author | Boccalini, Sara den Harder, Annemarie M. Witsenburg, Maarten Breur, Johannes P. J. M. Krestin, Gabriel P. van Beynum, Ingrid M. Attrach, Mohamed Stagnaro, Nicola Marasini, Maurizio de Jong, Pim A. Leiner, Tim Budde, Ricardo P. J. |
author_facet | Boccalini, Sara den Harder, Annemarie M. Witsenburg, Maarten Breur, Johannes P. J. M. Krestin, Gabriel P. van Beynum, Ingrid M. Attrach, Mohamed Stagnaro, Nicola Marasini, Maurizio de Jong, Pim A. Leiner, Tim Budde, Ricardo P. J. |
author_sort | Boccalini, Sara |
collection | PubMed |
description | BACKGROUND: Stents are commonly used to treat aortic coarctation. The objective of this study was to evaluate the post-implantation computed tomography (CT) image quality of different stent types used to treat aortic coarctation. METHODS: Adult and paediatric patients with stent-treated aortic coarctation who underwent contrast-enhanced CT were retrospectively included from three tertiary care centres. CT scans were subjectively scored for image quality using a 4-point scale (1 = unacceptable; 2 = poor; 3 = good; 4 = excellent). Furthermore, the amount of stent-induced blooming artefacts was measured as the percentage of the difference between outer and inner stent diameters over the outer stent diameter. RESULTS: A total of 35 children and 34 adults implanted with 71 stents of six different types were included. The most commonly used stent type was the Cheatham Platinum stent (52 stents, 73%). The subjective image quality of the Cheatham Platinum stents was moderate with a score of 2.0±0.8 (mean ± standard deviation) in children and 2.3±0.6 in adults. The image quality in patients with Formula stents was 2.3±1.2. The Cheatham Platinum stents induced 34–48% blooming, the Formula stents 44–55%. The image quality in patients with the less commonly used Atrium Advanta V12, IntraStent, AndraStent and Palmaz stents was scored 3 (good) to 4 (excellent) with less blooming. The electrocardiographic gating and tube voltage (kVp) did not affect image quality. CONCLUSIONS: There is a substantial variation in CT image quality and blooming artefacts for different stent types used to treat aortic coarctation. |
format | Online Article Text |
id | pubmed-6091724 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Springer International Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-60917242018-09-27 Computed tomography image quality of aortic stents in patients with aortic coarctation: a multicentre evaluation Boccalini, Sara den Harder, Annemarie M. Witsenburg, Maarten Breur, Johannes P. J. M. Krestin, Gabriel P. van Beynum, Ingrid M. Attrach, Mohamed Stagnaro, Nicola Marasini, Maurizio de Jong, Pim A. Leiner, Tim Budde, Ricardo P. J. Eur Radiol Exp Original Article BACKGROUND: Stents are commonly used to treat aortic coarctation. The objective of this study was to evaluate the post-implantation computed tomography (CT) image quality of different stent types used to treat aortic coarctation. METHODS: Adult and paediatric patients with stent-treated aortic coarctation who underwent contrast-enhanced CT were retrospectively included from three tertiary care centres. CT scans were subjectively scored for image quality using a 4-point scale (1 = unacceptable; 2 = poor; 3 = good; 4 = excellent). Furthermore, the amount of stent-induced blooming artefacts was measured as the percentage of the difference between outer and inner stent diameters over the outer stent diameter. RESULTS: A total of 35 children and 34 adults implanted with 71 stents of six different types were included. The most commonly used stent type was the Cheatham Platinum stent (52 stents, 73%). The subjective image quality of the Cheatham Platinum stents was moderate with a score of 2.0±0.8 (mean ± standard deviation) in children and 2.3±0.6 in adults. The image quality in patients with Formula stents was 2.3±1.2. The Cheatham Platinum stents induced 34–48% blooming, the Formula stents 44–55%. The image quality in patients with the less commonly used Atrium Advanta V12, IntraStent, AndraStent and Palmaz stents was scored 3 (good) to 4 (excellent) with less blooming. The electrocardiographic gating and tube voltage (kVp) did not affect image quality. CONCLUSIONS: There is a substantial variation in CT image quality and blooming artefacts for different stent types used to treat aortic coarctation. Springer International Publishing 2018-07-18 /pmc/articles/PMC6091724/ /pubmed/33252748 http://dx.doi.org/10.1186/s41747-018-0046-5 Text en © The Author(s) 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Original Article Boccalini, Sara den Harder, Annemarie M. Witsenburg, Maarten Breur, Johannes P. J. M. Krestin, Gabriel P. van Beynum, Ingrid M. Attrach, Mohamed Stagnaro, Nicola Marasini, Maurizio de Jong, Pim A. Leiner, Tim Budde, Ricardo P. J. Computed tomography image quality of aortic stents in patients with aortic coarctation: a multicentre evaluation |
title | Computed tomography image quality of aortic stents in patients with aortic coarctation: a multicentre evaluation |
title_full | Computed tomography image quality of aortic stents in patients with aortic coarctation: a multicentre evaluation |
title_fullStr | Computed tomography image quality of aortic stents in patients with aortic coarctation: a multicentre evaluation |
title_full_unstemmed | Computed tomography image quality of aortic stents in patients with aortic coarctation: a multicentre evaluation |
title_short | Computed tomography image quality of aortic stents in patients with aortic coarctation: a multicentre evaluation |
title_sort | computed tomography image quality of aortic stents in patients with aortic coarctation: a multicentre evaluation |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6091724/ https://www.ncbi.nlm.nih.gov/pubmed/33252748 http://dx.doi.org/10.1186/s41747-018-0046-5 |
work_keys_str_mv | AT boccalinisara computedtomographyimagequalityofaorticstentsinpatientswithaorticcoarctationamulticentreevaluation AT denharderannemariem computedtomographyimagequalityofaorticstentsinpatientswithaorticcoarctationamulticentreevaluation AT witsenburgmaarten computedtomographyimagequalityofaorticstentsinpatientswithaorticcoarctationamulticentreevaluation AT breurjohannespjm computedtomographyimagequalityofaorticstentsinpatientswithaorticcoarctationamulticentreevaluation AT krestingabrielp computedtomographyimagequalityofaorticstentsinpatientswithaorticcoarctationamulticentreevaluation AT vanbeynumingridm computedtomographyimagequalityofaorticstentsinpatientswithaorticcoarctationamulticentreevaluation AT attrachmohamed computedtomographyimagequalityofaorticstentsinpatientswithaorticcoarctationamulticentreevaluation AT stagnaronicola computedtomographyimagequalityofaorticstentsinpatientswithaorticcoarctationamulticentreevaluation AT marasinimaurizio computedtomographyimagequalityofaorticstentsinpatientswithaorticcoarctationamulticentreevaluation AT dejongpima computedtomographyimagequalityofaorticstentsinpatientswithaorticcoarctationamulticentreevaluation AT leinertim computedtomographyimagequalityofaorticstentsinpatientswithaorticcoarctationamulticentreevaluation AT buddericardopj computedtomographyimagequalityofaorticstentsinpatientswithaorticcoarctationamulticentreevaluation |