Cargando…
Complex Proximal Humeral Fracture Fixation with PHILOS Plate using Minimal Invasive Percutaneous Plate Osteosynthesis (MIPPO) Technique: A Series of 30 Patients
Introduction: Proximal humerus fracture fixation using plate osteosynthesis depends on the quality of the bone, design of the fixation devices and intra-operative soft tissue dissection. This study evaluates the functional outcome of minimally invasive percutaneous plate osteosynthesis using locking...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Malaysian Orthopaedic Association
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6092542/ https://www.ncbi.nlm.nih.gov/pubmed/30112124 http://dx.doi.org/10.5704/MOJ.1807.004 |
_version_ | 1783347547238039552 |
---|---|
author | Narayanan, VL Balasubramanian, N |
author_facet | Narayanan, VL Balasubramanian, N |
author_sort | Narayanan, VL |
collection | PubMed |
description | Introduction: Proximal humerus fracture fixation using plate osteosynthesis depends on the quality of the bone, design of the fixation devices and intra-operative soft tissue dissection. This study evaluates the functional outcome of minimally invasive percutaneous plate osteosynthesis using locking compression plate in proximal humerus fracture treatment. Materials and Methods: The study was conducted on 30 patients with complex proximal humerus fractures treated by minimally invasive percutaneous plate osteosynthesis using locking compression plate (PHILOS). There were 21 males and 9 females. The average age of our study group was 58.8 years. All the patients were evaluated at six weeks, three months, four months, six months and 12 months following surgery. Results: All patients had fracture union at an average of 13.2 weeks. The mean DASH score at the follow-up was 8.69 (2.5 to 17.16), the average range of flexion was 143.83 degrees (100 to 170 degrees) and abduction was 121.49 degrees (90 to 160 degrees). We had superficial infection in three patients which resolved with a short course of antibiotics. There was excellent outcome in 26 patients, good and fair in two patients each. Conclusion: Proximal humerus fractures treated with minimally invasive percutaneous plate osteosynthesis using locking compression plate with minimal soft tissue dissection, provides good functional outcome and early return of shoulder function. |
format | Online Article Text |
id | pubmed-6092542 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Malaysian Orthopaedic Association |
record_format | MEDLINE/PubMed |
spelling | pubmed-60925422018-08-15 Complex Proximal Humeral Fracture Fixation with PHILOS Plate using Minimal Invasive Percutaneous Plate Osteosynthesis (MIPPO) Technique: A Series of 30 Patients Narayanan, VL Balasubramanian, N Malays Orthop J Original Article Introduction: Proximal humerus fracture fixation using plate osteosynthesis depends on the quality of the bone, design of the fixation devices and intra-operative soft tissue dissection. This study evaluates the functional outcome of minimally invasive percutaneous plate osteosynthesis using locking compression plate in proximal humerus fracture treatment. Materials and Methods: The study was conducted on 30 patients with complex proximal humerus fractures treated by minimally invasive percutaneous plate osteosynthesis using locking compression plate (PHILOS). There were 21 males and 9 females. The average age of our study group was 58.8 years. All the patients were evaluated at six weeks, three months, four months, six months and 12 months following surgery. Results: All patients had fracture union at an average of 13.2 weeks. The mean DASH score at the follow-up was 8.69 (2.5 to 17.16), the average range of flexion was 143.83 degrees (100 to 170 degrees) and abduction was 121.49 degrees (90 to 160 degrees). We had superficial infection in three patients which resolved with a short course of antibiotics. There was excellent outcome in 26 patients, good and fair in two patients each. Conclusion: Proximal humerus fractures treated with minimally invasive percutaneous plate osteosynthesis using locking compression plate with minimal soft tissue dissection, provides good functional outcome and early return of shoulder function. Malaysian Orthopaedic Association 2018-07 /pmc/articles/PMC6092542/ /pubmed/30112124 http://dx.doi.org/10.5704/MOJ.1807.004 Text en © 2018 Malaysian Orthopaedic Association (MOA). All Rights Reserved http://creativecommons.org/licenses/by/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited |
spellingShingle | Original Article Narayanan, VL Balasubramanian, N Complex Proximal Humeral Fracture Fixation with PHILOS Plate using Minimal Invasive Percutaneous Plate Osteosynthesis (MIPPO) Technique: A Series of 30 Patients |
title | Complex Proximal Humeral Fracture Fixation with PHILOS Plate using Minimal Invasive Percutaneous Plate Osteosynthesis (MIPPO) Technique: A Series of 30 Patients |
title_full | Complex Proximal Humeral Fracture Fixation with PHILOS Plate using Minimal Invasive Percutaneous Plate Osteosynthesis (MIPPO) Technique: A Series of 30 Patients |
title_fullStr | Complex Proximal Humeral Fracture Fixation with PHILOS Plate using Minimal Invasive Percutaneous Plate Osteosynthesis (MIPPO) Technique: A Series of 30 Patients |
title_full_unstemmed | Complex Proximal Humeral Fracture Fixation with PHILOS Plate using Minimal Invasive Percutaneous Plate Osteosynthesis (MIPPO) Technique: A Series of 30 Patients |
title_short | Complex Proximal Humeral Fracture Fixation with PHILOS Plate using Minimal Invasive Percutaneous Plate Osteosynthesis (MIPPO) Technique: A Series of 30 Patients |
title_sort | complex proximal humeral fracture fixation with philos plate using minimal invasive percutaneous plate osteosynthesis (mippo) technique: a series of 30 patients |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6092542/ https://www.ncbi.nlm.nih.gov/pubmed/30112124 http://dx.doi.org/10.5704/MOJ.1807.004 |
work_keys_str_mv | AT narayananvl complexproximalhumeralfracturefixationwithphilosplateusingminimalinvasivepercutaneousplateosteosynthesismippotechniqueaseriesof30patients AT balasubramaniann complexproximalhumeralfracturefixationwithphilosplateusingminimalinvasivepercutaneousplateosteosynthesismippotechniqueaseriesof30patients |