Effect of the screw type (S2-alar-iliac and iliac), screw length, and screw head angle on the risk of screw and adjacent bone failures after a spinopelvic fixation technique: A finite element analysis
PURPOSE: Spinopelvic fixations involving the S2-alar-iliac (S2AI) and iliac screws are commonly used in various spinal fusion surgeries. This study aimed to compare the biomechanical characteristics, specifically the risk of screw and adjacent bone failures of S2AI screw fixation with those of iliac...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6095501/ https://www.ncbi.nlm.nih.gov/pubmed/30114271 http://dx.doi.org/10.1371/journal.pone.0201801 |
_version_ | 1783347945868886016 |
---|---|
author | Shin, Jong Ki Lim, Beop-Yong Goh, Tae Sik Son, Seung Min Kim, Hyung-Sik Lee, Jung Sub Lee, Chi-Seung |
author_facet | Shin, Jong Ki Lim, Beop-Yong Goh, Tae Sik Son, Seung Min Kim, Hyung-Sik Lee, Jung Sub Lee, Chi-Seung |
author_sort | Shin, Jong Ki |
collection | PubMed |
description | PURPOSE: Spinopelvic fixations involving the S2-alar-iliac (S2AI) and iliac screws are commonly used in various spinal fusion surgeries. This study aimed to compare the biomechanical characteristics, specifically the risk of screw and adjacent bone failures of S2AI screw fixation with those of iliac screw fixation using a finite element analysis (FEA). METHODS: A three-dimensional finite element (FE) model of a healthy spinopelvis was generated. The pedicle screws were placed on the L3-S1 with three different lengths of the S2AI and iliac screws (60 mm, 75 mm, and 90 mm). In particular, two types of the S2AI screw, 15°- and 30°-angled polyaxial screw, were adopted. Physiological loads, such as a combination of compression, torsion, and flexion/extension loads, were applied to the spinopelvic FE model, and the stress distribution as well as the maximum von Mises equivalent stress values were calculated. RESULTS: For the iliac screw, the highest stress on the screw was observed with the 75-mm screw, rather than the 60-mm screw. The bones around the iliac screw indicated that the maximum equivalent stress decreased as the screw length increased. For the S2AI screw, the lowest stress was observed in the 90-mm screw length with a 30° head angle. The bones around the S2AI screw indicated that the lowest stress was observed in the 90-mm screw length and a 15° head angle. CONCLUSIONS: It was found that the S2AI screw, rather than the iliac screw, reduced the risk of implant failure for the spinopelvic fixation technique, and the 90-mm screw length with a 15° head angle for the S2AI screw could be biomechanically advantageous. |
format | Online Article Text |
id | pubmed-6095501 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-60955012018-08-30 Effect of the screw type (S2-alar-iliac and iliac), screw length, and screw head angle on the risk of screw and adjacent bone failures after a spinopelvic fixation technique: A finite element analysis Shin, Jong Ki Lim, Beop-Yong Goh, Tae Sik Son, Seung Min Kim, Hyung-Sik Lee, Jung Sub Lee, Chi-Seung PLoS One Research Article PURPOSE: Spinopelvic fixations involving the S2-alar-iliac (S2AI) and iliac screws are commonly used in various spinal fusion surgeries. This study aimed to compare the biomechanical characteristics, specifically the risk of screw and adjacent bone failures of S2AI screw fixation with those of iliac screw fixation using a finite element analysis (FEA). METHODS: A three-dimensional finite element (FE) model of a healthy spinopelvis was generated. The pedicle screws were placed on the L3-S1 with three different lengths of the S2AI and iliac screws (60 mm, 75 mm, and 90 mm). In particular, two types of the S2AI screw, 15°- and 30°-angled polyaxial screw, were adopted. Physiological loads, such as a combination of compression, torsion, and flexion/extension loads, were applied to the spinopelvic FE model, and the stress distribution as well as the maximum von Mises equivalent stress values were calculated. RESULTS: For the iliac screw, the highest stress on the screw was observed with the 75-mm screw, rather than the 60-mm screw. The bones around the iliac screw indicated that the maximum equivalent stress decreased as the screw length increased. For the S2AI screw, the lowest stress was observed in the 90-mm screw length with a 30° head angle. The bones around the S2AI screw indicated that the lowest stress was observed in the 90-mm screw length and a 15° head angle. CONCLUSIONS: It was found that the S2AI screw, rather than the iliac screw, reduced the risk of implant failure for the spinopelvic fixation technique, and the 90-mm screw length with a 15° head angle for the S2AI screw could be biomechanically advantageous. Public Library of Science 2018-08-16 /pmc/articles/PMC6095501/ /pubmed/30114271 http://dx.doi.org/10.1371/journal.pone.0201801 Text en © 2018 Shin et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Shin, Jong Ki Lim, Beop-Yong Goh, Tae Sik Son, Seung Min Kim, Hyung-Sik Lee, Jung Sub Lee, Chi-Seung Effect of the screw type (S2-alar-iliac and iliac), screw length, and screw head angle on the risk of screw and adjacent bone failures after a spinopelvic fixation technique: A finite element analysis |
title | Effect of the screw type (S2-alar-iliac and iliac), screw length, and screw head angle on the risk of screw and adjacent bone failures after a spinopelvic fixation technique: A finite element analysis |
title_full | Effect of the screw type (S2-alar-iliac and iliac), screw length, and screw head angle on the risk of screw and adjacent bone failures after a spinopelvic fixation technique: A finite element analysis |
title_fullStr | Effect of the screw type (S2-alar-iliac and iliac), screw length, and screw head angle on the risk of screw and adjacent bone failures after a spinopelvic fixation technique: A finite element analysis |
title_full_unstemmed | Effect of the screw type (S2-alar-iliac and iliac), screw length, and screw head angle on the risk of screw and adjacent bone failures after a spinopelvic fixation technique: A finite element analysis |
title_short | Effect of the screw type (S2-alar-iliac and iliac), screw length, and screw head angle on the risk of screw and adjacent bone failures after a spinopelvic fixation technique: A finite element analysis |
title_sort | effect of the screw type (s2-alar-iliac and iliac), screw length, and screw head angle on the risk of screw and adjacent bone failures after a spinopelvic fixation technique: a finite element analysis |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6095501/ https://www.ncbi.nlm.nih.gov/pubmed/30114271 http://dx.doi.org/10.1371/journal.pone.0201801 |
work_keys_str_mv | AT shinjongki effectofthescrewtypes2alariliacandiliacscrewlengthandscrewheadangleontheriskofscrewandadjacentbonefailuresafteraspinopelvicfixationtechniqueafiniteelementanalysis AT limbeopyong effectofthescrewtypes2alariliacandiliacscrewlengthandscrewheadangleontheriskofscrewandadjacentbonefailuresafteraspinopelvicfixationtechniqueafiniteelementanalysis AT gohtaesik effectofthescrewtypes2alariliacandiliacscrewlengthandscrewheadangleontheriskofscrewandadjacentbonefailuresafteraspinopelvicfixationtechniqueafiniteelementanalysis AT sonseungmin effectofthescrewtypes2alariliacandiliacscrewlengthandscrewheadangleontheriskofscrewandadjacentbonefailuresafteraspinopelvicfixationtechniqueafiniteelementanalysis AT kimhyungsik effectofthescrewtypes2alariliacandiliacscrewlengthandscrewheadangleontheriskofscrewandadjacentbonefailuresafteraspinopelvicfixationtechniqueafiniteelementanalysis AT leejungsub effectofthescrewtypes2alariliacandiliacscrewlengthandscrewheadangleontheriskofscrewandadjacentbonefailuresafteraspinopelvicfixationtechniqueafiniteelementanalysis AT leechiseung effectofthescrewtypes2alariliacandiliacscrewlengthandscrewheadangleontheriskofscrewandadjacentbonefailuresafteraspinopelvicfixationtechniqueafiniteelementanalysis |