Cargando…

Association of renal systolic time intervals with brachial-ankle pulse wave velocity

Aims: The renal systolic time intervals (STIs), including renal pre-ejection period (PEP), renal ejection time (ET), and renal PEP/renal ET measured by renal Doppler ultrasound, were associated with poor cardiac function and adverse cardiac outcomes. However, the relationship between renal hemodynam...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Wen-Hsien, Hsu, Po-Chao, Chu, Chun-Yuan, Chen, Szu-Chia, Lee, Hung-Hao, Chen, Ying-Chih, Lee, Meng-Kuang, Lee, Chee-Siong, Yen, Hsueh-Wei, Lin, Tsung-Hsien, Voon, Wen-Chol, Lai, Wen-Ter, Sheu, Sheng-Hsiung, Kuo, Po-Lin, Su, Ho-Ming
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Ivyspring International Publisher 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6097254/
https://www.ncbi.nlm.nih.gov/pubmed/30123062
http://dx.doi.org/10.7150/ijms.24451
_version_ 1783348263313735680
author Lee, Wen-Hsien
Hsu, Po-Chao
Chu, Chun-Yuan
Chen, Szu-Chia
Lee, Hung-Hao
Chen, Ying-Chih
Lee, Meng-Kuang
Lee, Chee-Siong
Yen, Hsueh-Wei
Lin, Tsung-Hsien
Voon, Wen-Chol
Lai, Wen-Ter
Sheu, Sheng-Hsiung
Kuo, Po-Lin
Su, Ho-Ming
author_facet Lee, Wen-Hsien
Hsu, Po-Chao
Chu, Chun-Yuan
Chen, Szu-Chia
Lee, Hung-Hao
Chen, Ying-Chih
Lee, Meng-Kuang
Lee, Chee-Siong
Yen, Hsueh-Wei
Lin, Tsung-Hsien
Voon, Wen-Chol
Lai, Wen-Ter
Sheu, Sheng-Hsiung
Kuo, Po-Lin
Su, Ho-Ming
author_sort Lee, Wen-Hsien
collection PubMed
description Aims: The renal systolic time intervals (STIs), including renal pre-ejection period (PEP), renal ejection time (ET), and renal PEP/renal ET measured by renal Doppler ultrasound, were associated with poor cardiac function and adverse cardiac outcomes. However, the relationship between renal hemodynamic parameters and arterial stiffness in terms of brachial-ankle pulse wave velocity (baPWV) has never been evaluated. The aim of this study was to assess the relationship between renal STIs and baPWV. Methods: This cross-sectional study enrolled 230 patients. The renal hemodynamics was measured from Doppler ultrasonography and baPWV was measured from ABI-form device by an oscillometric method. Results: Patients with baPWV ≧ 1672 cm/s had a higher value of renal resistive index (RI) and lower values of renal PEP and renal PEP/ET (all P< 0.001). In univariable analysis, baPWV was significantly associated with renal RI, renal PEP, and renal PEP/renal ET (all P< 0.001). In multivariable analysis, renal PEP (unstandardized coefficient β = -3.185; 95% confidence interval = -5.169 to -1.201; P = 0.002) and renal PEP/renal ET (unstandardized coefficient β = -5.605; 95% CI = -10.217 to -0.992; P = 0.018), but not renal RI, were still the independent determinants of baPWV. Conclusion: Our results found that renal PEP and renal PEP/renal ET were independently associated with baPWV. Hence, renal STIs measured from renal echo may have a significant correlation with arterial stiffness.
format Online
Article
Text
id pubmed-6097254
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Ivyspring International Publisher
record_format MEDLINE/PubMed
spelling pubmed-60972542018-08-17 Association of renal systolic time intervals with brachial-ankle pulse wave velocity Lee, Wen-Hsien Hsu, Po-Chao Chu, Chun-Yuan Chen, Szu-Chia Lee, Hung-Hao Chen, Ying-Chih Lee, Meng-Kuang Lee, Chee-Siong Yen, Hsueh-Wei Lin, Tsung-Hsien Voon, Wen-Chol Lai, Wen-Ter Sheu, Sheng-Hsiung Kuo, Po-Lin Su, Ho-Ming Int J Med Sci Research Paper Aims: The renal systolic time intervals (STIs), including renal pre-ejection period (PEP), renal ejection time (ET), and renal PEP/renal ET measured by renal Doppler ultrasound, were associated with poor cardiac function and adverse cardiac outcomes. However, the relationship between renal hemodynamic parameters and arterial stiffness in terms of brachial-ankle pulse wave velocity (baPWV) has never been evaluated. The aim of this study was to assess the relationship between renal STIs and baPWV. Methods: This cross-sectional study enrolled 230 patients. The renal hemodynamics was measured from Doppler ultrasonography and baPWV was measured from ABI-form device by an oscillometric method. Results: Patients with baPWV ≧ 1672 cm/s had a higher value of renal resistive index (RI) and lower values of renal PEP and renal PEP/ET (all P< 0.001). In univariable analysis, baPWV was significantly associated with renal RI, renal PEP, and renal PEP/renal ET (all P< 0.001). In multivariable analysis, renal PEP (unstandardized coefficient β = -3.185; 95% confidence interval = -5.169 to -1.201; P = 0.002) and renal PEP/renal ET (unstandardized coefficient β = -5.605; 95% CI = -10.217 to -0.992; P = 0.018), but not renal RI, were still the independent determinants of baPWV. Conclusion: Our results found that renal PEP and renal PEP/renal ET were independently associated with baPWV. Hence, renal STIs measured from renal echo may have a significant correlation with arterial stiffness. Ivyspring International Publisher 2018-07-30 /pmc/articles/PMC6097254/ /pubmed/30123062 http://dx.doi.org/10.7150/ijms.24451 Text en © Ivyspring International Publisher This is an open access article distributed under the terms of the Creative Commons Attribution (CC BY-NC) license (https://creativecommons.org/licenses/by-nc/4.0/). See http://ivyspring.com/terms for full terms and conditions.
spellingShingle Research Paper
Lee, Wen-Hsien
Hsu, Po-Chao
Chu, Chun-Yuan
Chen, Szu-Chia
Lee, Hung-Hao
Chen, Ying-Chih
Lee, Meng-Kuang
Lee, Chee-Siong
Yen, Hsueh-Wei
Lin, Tsung-Hsien
Voon, Wen-Chol
Lai, Wen-Ter
Sheu, Sheng-Hsiung
Kuo, Po-Lin
Su, Ho-Ming
Association of renal systolic time intervals with brachial-ankle pulse wave velocity
title Association of renal systolic time intervals with brachial-ankle pulse wave velocity
title_full Association of renal systolic time intervals with brachial-ankle pulse wave velocity
title_fullStr Association of renal systolic time intervals with brachial-ankle pulse wave velocity
title_full_unstemmed Association of renal systolic time intervals with brachial-ankle pulse wave velocity
title_short Association of renal systolic time intervals with brachial-ankle pulse wave velocity
title_sort association of renal systolic time intervals with brachial-ankle pulse wave velocity
topic Research Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6097254/
https://www.ncbi.nlm.nih.gov/pubmed/30123062
http://dx.doi.org/10.7150/ijms.24451
work_keys_str_mv AT leewenhsien associationofrenalsystolictimeintervalswithbrachialanklepulsewavevelocity
AT hsupochao associationofrenalsystolictimeintervalswithbrachialanklepulsewavevelocity
AT chuchunyuan associationofrenalsystolictimeintervalswithbrachialanklepulsewavevelocity
AT chenszuchia associationofrenalsystolictimeintervalswithbrachialanklepulsewavevelocity
AT leehunghao associationofrenalsystolictimeintervalswithbrachialanklepulsewavevelocity
AT chenyingchih associationofrenalsystolictimeintervalswithbrachialanklepulsewavevelocity
AT leemengkuang associationofrenalsystolictimeintervalswithbrachialanklepulsewavevelocity
AT leecheesiong associationofrenalsystolictimeintervalswithbrachialanklepulsewavevelocity
AT yenhsuehwei associationofrenalsystolictimeintervalswithbrachialanklepulsewavevelocity
AT lintsunghsien associationofrenalsystolictimeintervalswithbrachialanklepulsewavevelocity
AT voonwenchol associationofrenalsystolictimeintervalswithbrachialanklepulsewavevelocity
AT laiwenter associationofrenalsystolictimeintervalswithbrachialanklepulsewavevelocity
AT sheushenghsiung associationofrenalsystolictimeintervalswithbrachialanklepulsewavevelocity
AT kuopolin associationofrenalsystolictimeintervalswithbrachialanklepulsewavevelocity
AT suhoming associationofrenalsystolictimeintervalswithbrachialanklepulsewavevelocity