Cargando…
Association of renal systolic time intervals with brachial-ankle pulse wave velocity
Aims: The renal systolic time intervals (STIs), including renal pre-ejection period (PEP), renal ejection time (ET), and renal PEP/renal ET measured by renal Doppler ultrasound, were associated with poor cardiac function and adverse cardiac outcomes. However, the relationship between renal hemodynam...
Autores principales: | , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Ivyspring International Publisher
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6097254/ https://www.ncbi.nlm.nih.gov/pubmed/30123062 http://dx.doi.org/10.7150/ijms.24451 |
_version_ | 1783348263313735680 |
---|---|
author | Lee, Wen-Hsien Hsu, Po-Chao Chu, Chun-Yuan Chen, Szu-Chia Lee, Hung-Hao Chen, Ying-Chih Lee, Meng-Kuang Lee, Chee-Siong Yen, Hsueh-Wei Lin, Tsung-Hsien Voon, Wen-Chol Lai, Wen-Ter Sheu, Sheng-Hsiung Kuo, Po-Lin Su, Ho-Ming |
author_facet | Lee, Wen-Hsien Hsu, Po-Chao Chu, Chun-Yuan Chen, Szu-Chia Lee, Hung-Hao Chen, Ying-Chih Lee, Meng-Kuang Lee, Chee-Siong Yen, Hsueh-Wei Lin, Tsung-Hsien Voon, Wen-Chol Lai, Wen-Ter Sheu, Sheng-Hsiung Kuo, Po-Lin Su, Ho-Ming |
author_sort | Lee, Wen-Hsien |
collection | PubMed |
description | Aims: The renal systolic time intervals (STIs), including renal pre-ejection period (PEP), renal ejection time (ET), and renal PEP/renal ET measured by renal Doppler ultrasound, were associated with poor cardiac function and adverse cardiac outcomes. However, the relationship between renal hemodynamic parameters and arterial stiffness in terms of brachial-ankle pulse wave velocity (baPWV) has never been evaluated. The aim of this study was to assess the relationship between renal STIs and baPWV. Methods: This cross-sectional study enrolled 230 patients. The renal hemodynamics was measured from Doppler ultrasonography and baPWV was measured from ABI-form device by an oscillometric method. Results: Patients with baPWV ≧ 1672 cm/s had a higher value of renal resistive index (RI) and lower values of renal PEP and renal PEP/ET (all P< 0.001). In univariable analysis, baPWV was significantly associated with renal RI, renal PEP, and renal PEP/renal ET (all P< 0.001). In multivariable analysis, renal PEP (unstandardized coefficient β = -3.185; 95% confidence interval = -5.169 to -1.201; P = 0.002) and renal PEP/renal ET (unstandardized coefficient β = -5.605; 95% CI = -10.217 to -0.992; P = 0.018), but not renal RI, were still the independent determinants of baPWV. Conclusion: Our results found that renal PEP and renal PEP/renal ET were independently associated with baPWV. Hence, renal STIs measured from renal echo may have a significant correlation with arterial stiffness. |
format | Online Article Text |
id | pubmed-6097254 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Ivyspring International Publisher |
record_format | MEDLINE/PubMed |
spelling | pubmed-60972542018-08-17 Association of renal systolic time intervals with brachial-ankle pulse wave velocity Lee, Wen-Hsien Hsu, Po-Chao Chu, Chun-Yuan Chen, Szu-Chia Lee, Hung-Hao Chen, Ying-Chih Lee, Meng-Kuang Lee, Chee-Siong Yen, Hsueh-Wei Lin, Tsung-Hsien Voon, Wen-Chol Lai, Wen-Ter Sheu, Sheng-Hsiung Kuo, Po-Lin Su, Ho-Ming Int J Med Sci Research Paper Aims: The renal systolic time intervals (STIs), including renal pre-ejection period (PEP), renal ejection time (ET), and renal PEP/renal ET measured by renal Doppler ultrasound, were associated with poor cardiac function and adverse cardiac outcomes. However, the relationship between renal hemodynamic parameters and arterial stiffness in terms of brachial-ankle pulse wave velocity (baPWV) has never been evaluated. The aim of this study was to assess the relationship between renal STIs and baPWV. Methods: This cross-sectional study enrolled 230 patients. The renal hemodynamics was measured from Doppler ultrasonography and baPWV was measured from ABI-form device by an oscillometric method. Results: Patients with baPWV ≧ 1672 cm/s had a higher value of renal resistive index (RI) and lower values of renal PEP and renal PEP/ET (all P< 0.001). In univariable analysis, baPWV was significantly associated with renal RI, renal PEP, and renal PEP/renal ET (all P< 0.001). In multivariable analysis, renal PEP (unstandardized coefficient β = -3.185; 95% confidence interval = -5.169 to -1.201; P = 0.002) and renal PEP/renal ET (unstandardized coefficient β = -5.605; 95% CI = -10.217 to -0.992; P = 0.018), but not renal RI, were still the independent determinants of baPWV. Conclusion: Our results found that renal PEP and renal PEP/renal ET were independently associated with baPWV. Hence, renal STIs measured from renal echo may have a significant correlation with arterial stiffness. Ivyspring International Publisher 2018-07-30 /pmc/articles/PMC6097254/ /pubmed/30123062 http://dx.doi.org/10.7150/ijms.24451 Text en © Ivyspring International Publisher This is an open access article distributed under the terms of the Creative Commons Attribution (CC BY-NC) license (https://creativecommons.org/licenses/by-nc/4.0/). See http://ivyspring.com/terms for full terms and conditions. |
spellingShingle | Research Paper Lee, Wen-Hsien Hsu, Po-Chao Chu, Chun-Yuan Chen, Szu-Chia Lee, Hung-Hao Chen, Ying-Chih Lee, Meng-Kuang Lee, Chee-Siong Yen, Hsueh-Wei Lin, Tsung-Hsien Voon, Wen-Chol Lai, Wen-Ter Sheu, Sheng-Hsiung Kuo, Po-Lin Su, Ho-Ming Association of renal systolic time intervals with brachial-ankle pulse wave velocity |
title | Association of renal systolic time intervals with brachial-ankle pulse wave velocity |
title_full | Association of renal systolic time intervals with brachial-ankle pulse wave velocity |
title_fullStr | Association of renal systolic time intervals with brachial-ankle pulse wave velocity |
title_full_unstemmed | Association of renal systolic time intervals with brachial-ankle pulse wave velocity |
title_short | Association of renal systolic time intervals with brachial-ankle pulse wave velocity |
title_sort | association of renal systolic time intervals with brachial-ankle pulse wave velocity |
topic | Research Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6097254/ https://www.ncbi.nlm.nih.gov/pubmed/30123062 http://dx.doi.org/10.7150/ijms.24451 |
work_keys_str_mv | AT leewenhsien associationofrenalsystolictimeintervalswithbrachialanklepulsewavevelocity AT hsupochao associationofrenalsystolictimeintervalswithbrachialanklepulsewavevelocity AT chuchunyuan associationofrenalsystolictimeintervalswithbrachialanklepulsewavevelocity AT chenszuchia associationofrenalsystolictimeintervalswithbrachialanklepulsewavevelocity AT leehunghao associationofrenalsystolictimeintervalswithbrachialanklepulsewavevelocity AT chenyingchih associationofrenalsystolictimeintervalswithbrachialanklepulsewavevelocity AT leemengkuang associationofrenalsystolictimeintervalswithbrachialanklepulsewavevelocity AT leecheesiong associationofrenalsystolictimeintervalswithbrachialanklepulsewavevelocity AT yenhsuehwei associationofrenalsystolictimeintervalswithbrachialanklepulsewavevelocity AT lintsunghsien associationofrenalsystolictimeintervalswithbrachialanklepulsewavevelocity AT voonwenchol associationofrenalsystolictimeintervalswithbrachialanklepulsewavevelocity AT laiwenter associationofrenalsystolictimeintervalswithbrachialanklepulsewavevelocity AT sheushenghsiung associationofrenalsystolictimeintervalswithbrachialanklepulsewavevelocity AT kuopolin associationofrenalsystolictimeintervalswithbrachialanklepulsewavevelocity AT suhoming associationofrenalsystolictimeintervalswithbrachialanklepulsewavevelocity |