Cargando…
Effect of low-intensity pulsed ultrasound on distraction osteogenesis: a systematic review and meta-analysis of randomized controlled trials
BACKGROUND: Low-intensity pulsed ultrasound (LIPUS) is a common adjunct used to promote bone healing for fresh fractures and non-unions, but its efficacy for bone distraction osteogenesis remains uncertain. This study aims to determine whether LIPUS can effectively and safely reduce the associated t...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6098620/ https://www.ncbi.nlm.nih.gov/pubmed/30119631 http://dx.doi.org/10.1186/s13018-018-0907-x |
_version_ | 1783348514848243712 |
---|---|
author | Lou, Shenghan Lv, Houchen Li, Zhirui Tang, Peifu Wang, Yansong |
author_facet | Lou, Shenghan Lv, Houchen Li, Zhirui Tang, Peifu Wang, Yansong |
author_sort | Lou, Shenghan |
collection | PubMed |
description | BACKGROUND: Low-intensity pulsed ultrasound (LIPUS) is a common adjunct used to promote bone healing for fresh fractures and non-unions, but its efficacy for bone distraction osteogenesis remains uncertain. This study aims to determine whether LIPUS can effectively and safely reduce the associated treatment time for patients undergoing distraction osteogenesis. METHODS: MEDLINE, EMBASE, and the Cochrane Library were searched until May 1, 2018, without language restriction. Studies should be randomized controlled trials (RCTs) or quasi-RCTs of LIPUS compared with sham devices or no devices in patients who undergo distraction osteogenesis. The primary outcome was the treatment time. The secondary outcome was the risk of complications. Treatment effects were assessed using mean differences, standardized mean differences, or risk ratios using a random-effects model. The Cochrane risk-of-bias tool was used to assess the risk of bias. The I(2) statistic was used to assess the heterogeneity. The GRADE system was used to evaluate the evidence quality. RESULTS: A total of 7 trials with 172 patients were included. The pooled results suggested that during the process of distraction osteogenesis, LIPUS therapy did not show a statistically significant reduction in the treatment time (mean difference, − 8.75 days/cm; 95% CI, − 20.68 to 3.18 days/cm; P = 0.15; I(2) = 72%) or in the risk of complications (risk ratio, 0.90 in favor of LIPUS; 95% CI, 0.65 to 1.24; I(2) = 0%). Also, LIPUS therapy did not show a significant effect on the radiological gap fill area (standardized mean difference, 0.48 in favor of control; 95%CI, − 1.49 to 0.52; I(2) = 0%), the histological gap fill length (standardized mean difference, 0.76 in favor of control; 95%CI, − 1.78 to 0.27; I(2) = 0%), or the bone density increase (standardized mean difference, 0.43 in favor of LIPUS; 95%CI, − 0.02 to 0.88; I(2) = 0%). CONCLUSIONS: Among patients undergoing distraction osteogenesis, neither the treatment time nor the risk of complications could be reduced by LIPUS therapy. The currently available evidence is insufficient to support the routine use of this intervention in clinical practice. TRIAL REGISTRATION: CRD 42017073596 ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s13018-018-0907-x) contains supplementary material, which is available to authorized users. |
format | Online Article Text |
id | pubmed-6098620 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-60986202018-08-23 Effect of low-intensity pulsed ultrasound on distraction osteogenesis: a systematic review and meta-analysis of randomized controlled trials Lou, Shenghan Lv, Houchen Li, Zhirui Tang, Peifu Wang, Yansong J Orthop Surg Res Systematic Review BACKGROUND: Low-intensity pulsed ultrasound (LIPUS) is a common adjunct used to promote bone healing for fresh fractures and non-unions, but its efficacy for bone distraction osteogenesis remains uncertain. This study aims to determine whether LIPUS can effectively and safely reduce the associated treatment time for patients undergoing distraction osteogenesis. METHODS: MEDLINE, EMBASE, and the Cochrane Library were searched until May 1, 2018, without language restriction. Studies should be randomized controlled trials (RCTs) or quasi-RCTs of LIPUS compared with sham devices or no devices in patients who undergo distraction osteogenesis. The primary outcome was the treatment time. The secondary outcome was the risk of complications. Treatment effects were assessed using mean differences, standardized mean differences, or risk ratios using a random-effects model. The Cochrane risk-of-bias tool was used to assess the risk of bias. The I(2) statistic was used to assess the heterogeneity. The GRADE system was used to evaluate the evidence quality. RESULTS: A total of 7 trials with 172 patients were included. The pooled results suggested that during the process of distraction osteogenesis, LIPUS therapy did not show a statistically significant reduction in the treatment time (mean difference, − 8.75 days/cm; 95% CI, − 20.68 to 3.18 days/cm; P = 0.15; I(2) = 72%) or in the risk of complications (risk ratio, 0.90 in favor of LIPUS; 95% CI, 0.65 to 1.24; I(2) = 0%). Also, LIPUS therapy did not show a significant effect on the radiological gap fill area (standardized mean difference, 0.48 in favor of control; 95%CI, − 1.49 to 0.52; I(2) = 0%), the histological gap fill length (standardized mean difference, 0.76 in favor of control; 95%CI, − 1.78 to 0.27; I(2) = 0%), or the bone density increase (standardized mean difference, 0.43 in favor of LIPUS; 95%CI, − 0.02 to 0.88; I(2) = 0%). CONCLUSIONS: Among patients undergoing distraction osteogenesis, neither the treatment time nor the risk of complications could be reduced by LIPUS therapy. The currently available evidence is insufficient to support the routine use of this intervention in clinical practice. TRIAL REGISTRATION: CRD 42017073596 ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s13018-018-0907-x) contains supplementary material, which is available to authorized users. BioMed Central 2018-08-17 /pmc/articles/PMC6098620/ /pubmed/30119631 http://dx.doi.org/10.1186/s13018-018-0907-x Text en © The Author(s). 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Systematic Review Lou, Shenghan Lv, Houchen Li, Zhirui Tang, Peifu Wang, Yansong Effect of low-intensity pulsed ultrasound on distraction osteogenesis: a systematic review and meta-analysis of randomized controlled trials |
title | Effect of low-intensity pulsed ultrasound on distraction osteogenesis: a systematic review and meta-analysis of randomized controlled trials |
title_full | Effect of low-intensity pulsed ultrasound on distraction osteogenesis: a systematic review and meta-analysis of randomized controlled trials |
title_fullStr | Effect of low-intensity pulsed ultrasound on distraction osteogenesis: a systematic review and meta-analysis of randomized controlled trials |
title_full_unstemmed | Effect of low-intensity pulsed ultrasound on distraction osteogenesis: a systematic review and meta-analysis of randomized controlled trials |
title_short | Effect of low-intensity pulsed ultrasound on distraction osteogenesis: a systematic review and meta-analysis of randomized controlled trials |
title_sort | effect of low-intensity pulsed ultrasound on distraction osteogenesis: a systematic review and meta-analysis of randomized controlled trials |
topic | Systematic Review |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6098620/ https://www.ncbi.nlm.nih.gov/pubmed/30119631 http://dx.doi.org/10.1186/s13018-018-0907-x |
work_keys_str_mv | AT loushenghan effectoflowintensitypulsedultrasoundondistractionosteogenesisasystematicreviewandmetaanalysisofrandomizedcontrolledtrials AT lvhouchen effectoflowintensitypulsedultrasoundondistractionosteogenesisasystematicreviewandmetaanalysisofrandomizedcontrolledtrials AT lizhirui effectoflowintensitypulsedultrasoundondistractionosteogenesisasystematicreviewandmetaanalysisofrandomizedcontrolledtrials AT tangpeifu effectoflowintensitypulsedultrasoundondistractionosteogenesisasystematicreviewandmetaanalysisofrandomizedcontrolledtrials AT wangyansong effectoflowintensitypulsedultrasoundondistractionosteogenesisasystematicreviewandmetaanalysisofrandomizedcontrolledtrials |