Validity and reliability of evaluating hip abductor strength using different normalization methods in a functional electromechanical device

The hip abductor muscles are vitally important for pelvis stability, and common strength deficits can negatively affect functionality. The muscle strength can be measured using different dynamometers and be evaluated in three positions (side-lying, standing, and supine). Obtained strength data can b...

Descripción completa

Detalles Bibliográficos
Autores principales: Cerda Vega, Enrique, Jerez-Mayorga, Daniel, Machado Payer, Ramón, Campos Jara, Christian, Guzman-Guzman, Iris, Reyes Ponce, Alvaro, Chirosa, Luis Javier
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6101381/
https://www.ncbi.nlm.nih.gov/pubmed/30125320
http://dx.doi.org/10.1371/journal.pone.0202248
_version_ 1783349010560450560
author Cerda Vega, Enrique
Jerez-Mayorga, Daniel
Machado Payer, Ramón
Campos Jara, Christian
Guzman-Guzman, Iris
Reyes Ponce, Alvaro
Chirosa, Luis Javier
author_facet Cerda Vega, Enrique
Jerez-Mayorga, Daniel
Machado Payer, Ramón
Campos Jara, Christian
Guzman-Guzman, Iris
Reyes Ponce, Alvaro
Chirosa, Luis Javier
author_sort Cerda Vega, Enrique
collection PubMed
description The hip abductor muscles are vitally important for pelvis stability, and common strength deficits can negatively affect functionality. The muscle strength can be measured using different dynamometers and be evaluated in three positions (side-lying, standing, and supine). Obtained strength data can be expressed in different ways, with data normalization providing more objective and comparable results. The aim of this study was to establish the validity and reliability of three protocols in evaluating the isometric strength of the hip abductor muscles. A new functional electromechanical dynamometer assessed strength in three positions, with findings subjected to three data normalization methods. In two identical sessions, the hip abductor strengths of 29 subjects were recorded in the side-lying, standing, and supine positions. Peak force was recorded in absolute terms and normalized against body mass, fat-free mass, and an allometric technique. The peak force recorded in the side-lying position was 30% and 27% higher than in the standing and supine positions, respectively, independent of data normalization methodology. High inter-protocol correlations were found (r: 0.72 to 0.98, p ≤ 0.001). The supine position with allometric data normalization had the highest test-retest reliability (0.94 intraclass correlation coefficient and 5.64% coefficient of variation). In contrast, the side-lying position with body mass data normalization had a 0.66 intraclass correlation coefficient and 9.8% coefficient of variation. In conclusion, the functional electromechanical dynamometer is a valid device for measuring isometric strength in the hip abductor muscles. The three assessed positions are reliable, although the supine position with allometric data normalization provided the best results.
format Online
Article
Text
id pubmed-6101381
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-61013812018-08-30 Validity and reliability of evaluating hip abductor strength using different normalization methods in a functional electromechanical device Cerda Vega, Enrique Jerez-Mayorga, Daniel Machado Payer, Ramón Campos Jara, Christian Guzman-Guzman, Iris Reyes Ponce, Alvaro Chirosa, Luis Javier PLoS One Research Article The hip abductor muscles are vitally important for pelvis stability, and common strength deficits can negatively affect functionality. The muscle strength can be measured using different dynamometers and be evaluated in three positions (side-lying, standing, and supine). Obtained strength data can be expressed in different ways, with data normalization providing more objective and comparable results. The aim of this study was to establish the validity and reliability of three protocols in evaluating the isometric strength of the hip abductor muscles. A new functional electromechanical dynamometer assessed strength in three positions, with findings subjected to three data normalization methods. In two identical sessions, the hip abductor strengths of 29 subjects were recorded in the side-lying, standing, and supine positions. Peak force was recorded in absolute terms and normalized against body mass, fat-free mass, and an allometric technique. The peak force recorded in the side-lying position was 30% and 27% higher than in the standing and supine positions, respectively, independent of data normalization methodology. High inter-protocol correlations were found (r: 0.72 to 0.98, p ≤ 0.001). The supine position with allometric data normalization had the highest test-retest reliability (0.94 intraclass correlation coefficient and 5.64% coefficient of variation). In contrast, the side-lying position with body mass data normalization had a 0.66 intraclass correlation coefficient and 9.8% coefficient of variation. In conclusion, the functional electromechanical dynamometer is a valid device for measuring isometric strength in the hip abductor muscles. The three assessed positions are reliable, although the supine position with allometric data normalization provided the best results. Public Library of Science 2018-08-20 /pmc/articles/PMC6101381/ /pubmed/30125320 http://dx.doi.org/10.1371/journal.pone.0202248 Text en © 2018 Cerda Vega et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Cerda Vega, Enrique
Jerez-Mayorga, Daniel
Machado Payer, Ramón
Campos Jara, Christian
Guzman-Guzman, Iris
Reyes Ponce, Alvaro
Chirosa, Luis Javier
Validity and reliability of evaluating hip abductor strength using different normalization methods in a functional electromechanical device
title Validity and reliability of evaluating hip abductor strength using different normalization methods in a functional electromechanical device
title_full Validity and reliability of evaluating hip abductor strength using different normalization methods in a functional electromechanical device
title_fullStr Validity and reliability of evaluating hip abductor strength using different normalization methods in a functional electromechanical device
title_full_unstemmed Validity and reliability of evaluating hip abductor strength using different normalization methods in a functional electromechanical device
title_short Validity and reliability of evaluating hip abductor strength using different normalization methods in a functional electromechanical device
title_sort validity and reliability of evaluating hip abductor strength using different normalization methods in a functional electromechanical device
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6101381/
https://www.ncbi.nlm.nih.gov/pubmed/30125320
http://dx.doi.org/10.1371/journal.pone.0202248
work_keys_str_mv AT cerdavegaenrique validityandreliabilityofevaluatinghipabductorstrengthusingdifferentnormalizationmethodsinafunctionalelectromechanicaldevice
AT jerezmayorgadaniel validityandreliabilityofevaluatinghipabductorstrengthusingdifferentnormalizationmethodsinafunctionalelectromechanicaldevice
AT machadopayerramon validityandreliabilityofevaluatinghipabductorstrengthusingdifferentnormalizationmethodsinafunctionalelectromechanicaldevice
AT camposjarachristian validityandreliabilityofevaluatinghipabductorstrengthusingdifferentnormalizationmethodsinafunctionalelectromechanicaldevice
AT guzmanguzmaniris validityandreliabilityofevaluatinghipabductorstrengthusingdifferentnormalizationmethodsinafunctionalelectromechanicaldevice
AT reyesponcealvaro validityandreliabilityofevaluatinghipabductorstrengthusingdifferentnormalizationmethodsinafunctionalelectromechanicaldevice
AT chirosaluisjavier validityandreliabilityofevaluatinghipabductorstrengthusingdifferentnormalizationmethodsinafunctionalelectromechanicaldevice