Cargando…
PillCamColon2 after incomplete colonoscopy - A prospective multicenter study
AIM: To evaluate the ability of PillCamColon2 to visualize colonic segments missed by incomplete optical colonoscopy (OC) and to assess the diagnostic yield. METHODS: This prospective multicentre study included 81 patients from nine centres who underwent second-generation colon capsule endoscopy (CC...
Autores principales: | , , , , , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Baishideng Publishing Group Inc
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6102503/ https://www.ncbi.nlm.nih.gov/pubmed/30131662 http://dx.doi.org/10.3748/wjg.v24.i31.3556 |
_version_ | 1783349178337853440 |
---|---|
author | Baltes, Peter Bota, Marc Albert, Jörg Philipper, Michael Hörster, Hans-Georg Hagenmüller, Friedrich Steinbrück, Ingo Jakobs, Ralf Bechtler, Matthias Hartmann, Dirk Neuhaus, Horst Charton, Jean-Pierre Mayershofer, Rupert Hohn, Horst Rösch, Thomas Groth, Stefan Nowak, Tanja Wohlmuth, Peter Keuchel, Martin |
author_facet | Baltes, Peter Bota, Marc Albert, Jörg Philipper, Michael Hörster, Hans-Georg Hagenmüller, Friedrich Steinbrück, Ingo Jakobs, Ralf Bechtler, Matthias Hartmann, Dirk Neuhaus, Horst Charton, Jean-Pierre Mayershofer, Rupert Hohn, Horst Rösch, Thomas Groth, Stefan Nowak, Tanja Wohlmuth, Peter Keuchel, Martin |
author_sort | Baltes, Peter |
collection | PubMed |
description | AIM: To evaluate the ability of PillCamColon2 to visualize colonic segments missed by incomplete optical colonoscopy (OC) and to assess the diagnostic yield. METHODS: This prospective multicentre study included 81 patients from nine centres who underwent second-generation colon capsule endoscopy (CCE) following incomplete OC performed by an experienced gastroenterologist (> 1000 colonoscopies). Patients with stenosis were excluded. According to patient preferences, CCE was performed the following day (protocol A) after staying on clear liquids and 0.75 L Moviprep in the morning or within 30 d after new split-dose Moviprep (protocol B). Boosts consisted of 0.75 L and 0.25 L Moviprep, and phospho-soda was given as a rescue if the capsule was not excreted after seven hours. RESULTS: Seventy-four patients were analysed (51% of them in group A; 49% in group B). Bowel cleansing was adequate in 67% of cases, and CCE could visualize colonic segments missed by incomplete colonoscopy in 90% of patients under protocol A and 97% of patients under protocol B (P = 0.35, n.s.). Significant polyps including adenocarcinoma were detected in 24% of cases. Detection rates for all polyps and significant polyps per patient were similar in both protocols. Polyps were found predominantly in the right colon (86%) in segments that were not reached by OC. Extracolonic findings - such as reflux esophagitis, suspected Barrett esophagus, upper GI-bleeding, gastric polyps, gastric erosions and angiectasia - were detected in eight patients. PillCamColon2 capsule was retained in the ileum of one patient (1.4%) without symptoms and removed during an uneventful resection for unknown Crohn’s disease that was diagnosed as the cause of anemia, which was the indication for colonoscopy. CCE was well tolerated. One patient suffered from self-limiting vomiting after consuming the phospho-soda. CONCLUSION: Second-generation CCE using a low-volume preparation is useful after incomplete OC, and it allows for the detection of additional relevant findings, but cleansing efficiency could be improved. |
format | Online Article Text |
id | pubmed-6102503 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Baishideng Publishing Group Inc |
record_format | MEDLINE/PubMed |
spelling | pubmed-61025032018-08-21 PillCamColon2 after incomplete colonoscopy - A prospective multicenter study Baltes, Peter Bota, Marc Albert, Jörg Philipper, Michael Hörster, Hans-Georg Hagenmüller, Friedrich Steinbrück, Ingo Jakobs, Ralf Bechtler, Matthias Hartmann, Dirk Neuhaus, Horst Charton, Jean-Pierre Mayershofer, Rupert Hohn, Horst Rösch, Thomas Groth, Stefan Nowak, Tanja Wohlmuth, Peter Keuchel, Martin World J Gastroenterol Prospective Study AIM: To evaluate the ability of PillCamColon2 to visualize colonic segments missed by incomplete optical colonoscopy (OC) and to assess the diagnostic yield. METHODS: This prospective multicentre study included 81 patients from nine centres who underwent second-generation colon capsule endoscopy (CCE) following incomplete OC performed by an experienced gastroenterologist (> 1000 colonoscopies). Patients with stenosis were excluded. According to patient preferences, CCE was performed the following day (protocol A) after staying on clear liquids and 0.75 L Moviprep in the morning or within 30 d after new split-dose Moviprep (protocol B). Boosts consisted of 0.75 L and 0.25 L Moviprep, and phospho-soda was given as a rescue if the capsule was not excreted after seven hours. RESULTS: Seventy-four patients were analysed (51% of them in group A; 49% in group B). Bowel cleansing was adequate in 67% of cases, and CCE could visualize colonic segments missed by incomplete colonoscopy in 90% of patients under protocol A and 97% of patients under protocol B (P = 0.35, n.s.). Significant polyps including adenocarcinoma were detected in 24% of cases. Detection rates for all polyps and significant polyps per patient were similar in both protocols. Polyps were found predominantly in the right colon (86%) in segments that were not reached by OC. Extracolonic findings - such as reflux esophagitis, suspected Barrett esophagus, upper GI-bleeding, gastric polyps, gastric erosions and angiectasia - were detected in eight patients. PillCamColon2 capsule was retained in the ileum of one patient (1.4%) without symptoms and removed during an uneventful resection for unknown Crohn’s disease that was diagnosed as the cause of anemia, which was the indication for colonoscopy. CCE was well tolerated. One patient suffered from self-limiting vomiting after consuming the phospho-soda. CONCLUSION: Second-generation CCE using a low-volume preparation is useful after incomplete OC, and it allows for the detection of additional relevant findings, but cleansing efficiency could be improved. Baishideng Publishing Group Inc 2018-08-21 2018-08-21 /pmc/articles/PMC6102503/ /pubmed/30131662 http://dx.doi.org/10.3748/wjg.v24.i31.3556 Text en ©The Author(s) 2018. Published by Baishideng Publishing Group Inc. All rights reserved. http://creativecommons.org/licenses/by-nc/4.0/ This article is an open-access article which was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. |
spellingShingle | Prospective Study Baltes, Peter Bota, Marc Albert, Jörg Philipper, Michael Hörster, Hans-Georg Hagenmüller, Friedrich Steinbrück, Ingo Jakobs, Ralf Bechtler, Matthias Hartmann, Dirk Neuhaus, Horst Charton, Jean-Pierre Mayershofer, Rupert Hohn, Horst Rösch, Thomas Groth, Stefan Nowak, Tanja Wohlmuth, Peter Keuchel, Martin PillCamColon2 after incomplete colonoscopy - A prospective multicenter study |
title | PillCamColon2 after incomplete colonoscopy - A prospective multicenter study |
title_full | PillCamColon2 after incomplete colonoscopy - A prospective multicenter study |
title_fullStr | PillCamColon2 after incomplete colonoscopy - A prospective multicenter study |
title_full_unstemmed | PillCamColon2 after incomplete colonoscopy - A prospective multicenter study |
title_short | PillCamColon2 after incomplete colonoscopy - A prospective multicenter study |
title_sort | pillcamcolon2 after incomplete colonoscopy - a prospective multicenter study |
topic | Prospective Study |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6102503/ https://www.ncbi.nlm.nih.gov/pubmed/30131662 http://dx.doi.org/10.3748/wjg.v24.i31.3556 |
work_keys_str_mv | AT baltespeter pillcamcolon2afterincompletecolonoscopyaprospectivemulticenterstudy AT botamarc pillcamcolon2afterincompletecolonoscopyaprospectivemulticenterstudy AT albertjorg pillcamcolon2afterincompletecolonoscopyaprospectivemulticenterstudy AT philippermichael pillcamcolon2afterincompletecolonoscopyaprospectivemulticenterstudy AT horsterhansgeorg pillcamcolon2afterincompletecolonoscopyaprospectivemulticenterstudy AT hagenmullerfriedrich pillcamcolon2afterincompletecolonoscopyaprospectivemulticenterstudy AT steinbruckingo pillcamcolon2afterincompletecolonoscopyaprospectivemulticenterstudy AT jakobsralf pillcamcolon2afterincompletecolonoscopyaprospectivemulticenterstudy AT bechtlermatthias pillcamcolon2afterincompletecolonoscopyaprospectivemulticenterstudy AT hartmanndirk pillcamcolon2afterincompletecolonoscopyaprospectivemulticenterstudy AT neuhaushorst pillcamcolon2afterincompletecolonoscopyaprospectivemulticenterstudy AT chartonjeanpierre pillcamcolon2afterincompletecolonoscopyaprospectivemulticenterstudy AT mayershoferrupert pillcamcolon2afterincompletecolonoscopyaprospectivemulticenterstudy AT hohnhorst pillcamcolon2afterincompletecolonoscopyaprospectivemulticenterstudy AT roschthomas pillcamcolon2afterincompletecolonoscopyaprospectivemulticenterstudy AT grothstefan pillcamcolon2afterincompletecolonoscopyaprospectivemulticenterstudy AT nowaktanja pillcamcolon2afterincompletecolonoscopyaprospectivemulticenterstudy AT wohlmuthpeter pillcamcolon2afterincompletecolonoscopyaprospectivemulticenterstudy AT keuchelmartin pillcamcolon2afterincompletecolonoscopyaprospectivemulticenterstudy |