Comparative Evaluation of the Viscosity and Length of Resin Tags of Conventional and Hydrophilic Pit and Fissure Sealants on Permanent Molars: An In vitro Study

BACKGROUND: The World Health Organization considers sealing the pit and fissures as a primary preventive measure and is one of the most effective, least invasive means to ensure the complete protection of the occlusal surface from the carious phenomenon. In vitro tests play a vital role in providing...

Descripción completa

Detalles Bibliográficos
Autores principales: Prabakar, Jayashri, John, Joseph, Arumugham, I Meignana, Kumar, R Pradeep, Sakthi, D. Sri
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6104359/
https://www.ncbi.nlm.nih.gov/pubmed/30166832
http://dx.doi.org/10.4103/ccd.ccd_131_18
_version_ 1783349474135900160
author Prabakar, Jayashri
John, Joseph
Arumugham, I Meignana
Kumar, R Pradeep
Sakthi, D. Sri
author_facet Prabakar, Jayashri
John, Joseph
Arumugham, I Meignana
Kumar, R Pradeep
Sakthi, D. Sri
author_sort Prabakar, Jayashri
collection PubMed
description BACKGROUND: The World Health Organization considers sealing the pit and fissures as a primary preventive measure and is one of the most effective, least invasive means to ensure the complete protection of the occlusal surface from the carious phenomenon. In vitro tests play a vital role in providing the necessary information regarding the efficacy of newer brands of sealants in a short period. Therefore, the aim of the present study was to evaluate and compare the viscosity and length of resin tag of conventional and hydrophilic sealant on permanent molars. MATERIALS AND METHODS: Twenty extracted third molars were randomly divided into two groups: Group I: Conventional sealant (Clinpro 3M ESPE) and Group II: Hydrophilic sealant (UltraSeal XT Hydro). Occlusal surfaces of each tooth were pretreated with the acid etchant, and the respective sealants were placed. Both the groups were then subjected to thermocycling and sectioned longitudinally. The sectioned tooth specimens were examined under scanning electron microscope for resin tag length measurements. Viscosities were evaluated using an Anton Paar viscometer. Independent t-test was used to compare the difference in mean resin tag length of Group I and Group II sealants. RESULTS: Viscosity measurements of Group I and Group II were found to be 0.9 mega Pascal (MPa) and 0.7 MPa and the mean resin tag length of Group II (10.03 ± 1.00 μm) was found to be higher than Group I (7.46 ± 0.95 μm) and was found to be significant statistically (P = 0.001). CONCLUSION: Based on the results of the present study, it can be concluded that Group II sealant exhibited lower viscosity and formed resin tag of sufficient length than that of Group I sealants. Therefore, hydrophilic sealant showed better results as compared to a conventional sealant.
format Online
Article
Text
id pubmed-6104359
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-61043592018-08-30 Comparative Evaluation of the Viscosity and Length of Resin Tags of Conventional and Hydrophilic Pit and Fissure Sealants on Permanent Molars: An In vitro Study Prabakar, Jayashri John, Joseph Arumugham, I Meignana Kumar, R Pradeep Sakthi, D. Sri Contemp Clin Dent Original Article BACKGROUND: The World Health Organization considers sealing the pit and fissures as a primary preventive measure and is one of the most effective, least invasive means to ensure the complete protection of the occlusal surface from the carious phenomenon. In vitro tests play a vital role in providing the necessary information regarding the efficacy of newer brands of sealants in a short period. Therefore, the aim of the present study was to evaluate and compare the viscosity and length of resin tag of conventional and hydrophilic sealant on permanent molars. MATERIALS AND METHODS: Twenty extracted third molars were randomly divided into two groups: Group I: Conventional sealant (Clinpro 3M ESPE) and Group II: Hydrophilic sealant (UltraSeal XT Hydro). Occlusal surfaces of each tooth were pretreated with the acid etchant, and the respective sealants were placed. Both the groups were then subjected to thermocycling and sectioned longitudinally. The sectioned tooth specimens were examined under scanning electron microscope for resin tag length measurements. Viscosities were evaluated using an Anton Paar viscometer. Independent t-test was used to compare the difference in mean resin tag length of Group I and Group II sealants. RESULTS: Viscosity measurements of Group I and Group II were found to be 0.9 mega Pascal (MPa) and 0.7 MPa and the mean resin tag length of Group II (10.03 ± 1.00 μm) was found to be higher than Group I (7.46 ± 0.95 μm) and was found to be significant statistically (P = 0.001). CONCLUSION: Based on the results of the present study, it can be concluded that Group II sealant exhibited lower viscosity and formed resin tag of sufficient length than that of Group I sealants. Therefore, hydrophilic sealant showed better results as compared to a conventional sealant. Medknow Publications & Media Pvt Ltd 2018 /pmc/articles/PMC6104359/ /pubmed/30166832 http://dx.doi.org/10.4103/ccd.ccd_131_18 Text en Copyright: © 2018 Contemporary Clinical Dentistry http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Prabakar, Jayashri
John, Joseph
Arumugham, I Meignana
Kumar, R Pradeep
Sakthi, D. Sri
Comparative Evaluation of the Viscosity and Length of Resin Tags of Conventional and Hydrophilic Pit and Fissure Sealants on Permanent Molars: An In vitro Study
title Comparative Evaluation of the Viscosity and Length of Resin Tags of Conventional and Hydrophilic Pit and Fissure Sealants on Permanent Molars: An In vitro Study
title_full Comparative Evaluation of the Viscosity and Length of Resin Tags of Conventional and Hydrophilic Pit and Fissure Sealants on Permanent Molars: An In vitro Study
title_fullStr Comparative Evaluation of the Viscosity and Length of Resin Tags of Conventional and Hydrophilic Pit and Fissure Sealants on Permanent Molars: An In vitro Study
title_full_unstemmed Comparative Evaluation of the Viscosity and Length of Resin Tags of Conventional and Hydrophilic Pit and Fissure Sealants on Permanent Molars: An In vitro Study
title_short Comparative Evaluation of the Viscosity and Length of Resin Tags of Conventional and Hydrophilic Pit and Fissure Sealants on Permanent Molars: An In vitro Study
title_sort comparative evaluation of the viscosity and length of resin tags of conventional and hydrophilic pit and fissure sealants on permanent molars: an in vitro study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6104359/
https://www.ncbi.nlm.nih.gov/pubmed/30166832
http://dx.doi.org/10.4103/ccd.ccd_131_18
work_keys_str_mv AT prabakarjayashri comparativeevaluationoftheviscosityandlengthofresintagsofconventionalandhydrophilicpitandfissuresealantsonpermanentmolarsaninvitrostudy
AT johnjoseph comparativeevaluationoftheviscosityandlengthofresintagsofconventionalandhydrophilicpitandfissuresealantsonpermanentmolarsaninvitrostudy
AT arumughamimeignana comparativeevaluationoftheviscosityandlengthofresintagsofconventionalandhydrophilicpitandfissuresealantsonpermanentmolarsaninvitrostudy
AT kumarrpradeep comparativeevaluationoftheviscosityandlengthofresintagsofconventionalandhydrophilicpitandfissuresealantsonpermanentmolarsaninvitrostudy
AT sakthidsri comparativeevaluationoftheviscosityandlengthofresintagsofconventionalandhydrophilicpitandfissuresealantsonpermanentmolarsaninvitrostudy