Cargando…
The accuracy of a 3D printing surgical guide determined by CBCT and model analysis
PURPOSE: The aim of this clinical study was to assess the accuracy of the implants placed using a universal digital surgical guide. MATERIALS AND METHODS: Among 17 patients, 28 posterior implants were included in this study. The digital image of the soft tissue acquired from cast scan and hard tissu...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Academy of Prosthodontics
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6104503/ https://www.ncbi.nlm.nih.gov/pubmed/30140394 http://dx.doi.org/10.4047/jap.2018.10.4.279 |
_version_ | 1783349501880172544 |
---|---|
author | Ma, Boyoung Park, Taeseok Chun, Inkon Yun, Kwidug |
author_facet | Ma, Boyoung Park, Taeseok Chun, Inkon Yun, Kwidug |
author_sort | Ma, Boyoung |
collection | PubMed |
description | PURPOSE: The aim of this clinical study was to assess the accuracy of the implants placed using a universal digital surgical guide. MATERIALS AND METHODS: Among 17 patients, 28 posterior implants were included in this study. The digital image of the soft tissue acquired from cast scan and hard tissue from CBCT have been superimposed and planned the location, length, diameter of the implant fixture. Then digital surgical guides were created using 3D printer. Each of angle deviations, coronal, apical, depth deviations of planned and actually placed implants were calculated using CBCT scans and casts. To compare implant positioning errors by CBCT scans and plaster casts, data were analyzed with independent samples t-test. RESULTS: The results of the implant positioning errors calculated by CBCT and casts were as follows. The means for CBCT analyses were: angle deviation: 4.74 ± 2.06°, coronal deviation: 1.37 ± 0.80 mm, and apical deviation: 1.77 ± 0.86 mm. The means for cast analyses were: angle deviation: 2.43 ± 1.13°, coronal deviation: 0.82 ± 0.44 mm, apical deviation: 1.19 ± 0.46 mm, and depth deviation: 0.03 ± 0.65 mm. There were statistically significant differences between the deviations of CBCT scans and cast. CONCLUSION: The model analysis showed lower deviation value comparing the CBCT analysis. The angle and length deviation value of the universal digital guide stent were accepted clinically. |
format | Online Article Text |
id | pubmed-6104503 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | The Korean Academy of Prosthodontics |
record_format | MEDLINE/PubMed |
spelling | pubmed-61045032018-08-23 The accuracy of a 3D printing surgical guide determined by CBCT and model analysis Ma, Boyoung Park, Taeseok Chun, Inkon Yun, Kwidug J Adv Prosthodont Original Article PURPOSE: The aim of this clinical study was to assess the accuracy of the implants placed using a universal digital surgical guide. MATERIALS AND METHODS: Among 17 patients, 28 posterior implants were included in this study. The digital image of the soft tissue acquired from cast scan and hard tissue from CBCT have been superimposed and planned the location, length, diameter of the implant fixture. Then digital surgical guides were created using 3D printer. Each of angle deviations, coronal, apical, depth deviations of planned and actually placed implants were calculated using CBCT scans and casts. To compare implant positioning errors by CBCT scans and plaster casts, data were analyzed with independent samples t-test. RESULTS: The results of the implant positioning errors calculated by CBCT and casts were as follows. The means for CBCT analyses were: angle deviation: 4.74 ± 2.06°, coronal deviation: 1.37 ± 0.80 mm, and apical deviation: 1.77 ± 0.86 mm. The means for cast analyses were: angle deviation: 2.43 ± 1.13°, coronal deviation: 0.82 ± 0.44 mm, apical deviation: 1.19 ± 0.46 mm, and depth deviation: 0.03 ± 0.65 mm. There were statistically significant differences between the deviations of CBCT scans and cast. CONCLUSION: The model analysis showed lower deviation value comparing the CBCT analysis. The angle and length deviation value of the universal digital guide stent were accepted clinically. The Korean Academy of Prosthodontics 2018-08 2018-08-17 /pmc/articles/PMC6104503/ /pubmed/30140394 http://dx.doi.org/10.4047/jap.2018.10.4.279 Text en © 2018 The Korean Academy of Prosthodontics http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Ma, Boyoung Park, Taeseok Chun, Inkon Yun, Kwidug The accuracy of a 3D printing surgical guide determined by CBCT and model analysis |
title | The accuracy of a 3D printing surgical guide determined by CBCT and model analysis |
title_full | The accuracy of a 3D printing surgical guide determined by CBCT and model analysis |
title_fullStr | The accuracy of a 3D printing surgical guide determined by CBCT and model analysis |
title_full_unstemmed | The accuracy of a 3D printing surgical guide determined by CBCT and model analysis |
title_short | The accuracy of a 3D printing surgical guide determined by CBCT and model analysis |
title_sort | accuracy of a 3d printing surgical guide determined by cbct and model analysis |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6104503/ https://www.ncbi.nlm.nih.gov/pubmed/30140394 http://dx.doi.org/10.4047/jap.2018.10.4.279 |
work_keys_str_mv | AT maboyoung theaccuracyofa3dprintingsurgicalguidedeterminedbycbctandmodelanalysis AT parktaeseok theaccuracyofa3dprintingsurgicalguidedeterminedbycbctandmodelanalysis AT chuninkon theaccuracyofa3dprintingsurgicalguidedeterminedbycbctandmodelanalysis AT yunkwidug theaccuracyofa3dprintingsurgicalguidedeterminedbycbctandmodelanalysis AT maboyoung accuracyofa3dprintingsurgicalguidedeterminedbycbctandmodelanalysis AT parktaeseok accuracyofa3dprintingsurgicalguidedeterminedbycbctandmodelanalysis AT chuninkon accuracyofa3dprintingsurgicalguidedeterminedbycbctandmodelanalysis AT yunkwidug accuracyofa3dprintingsurgicalguidedeterminedbycbctandmodelanalysis |