Cargando…

Intra- and Interrater Reliability of Sagittal Spinopelvic Parameters on Full-Spine Radiographs in Adults With Symptomatic Spinal Disorders

BACKGROUND/AIMS: To evaluate the intra- and interrater reliability (I-IR) of sagittal spinopelvic parameters from digital full-spine plain radiographs with basic software tools in an unselected adult population with degenerative spinal complaints who were evaluated for surgery. METHODS: Forty-nine a...

Descripción completa

Detalles Bibliográficos
Autores principales: Kyrölä, Kati Kristiina, Salme, Järvenpää, Tuija, Järviluoma, Tero, Irmola, Eero, Kauppinen, Arja, Häkkinen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Spinal Neurosurgery Society 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6104729/
https://www.ncbi.nlm.nih.gov/pubmed/29991248
http://dx.doi.org/10.14245/ns.1836054.027
_version_ 1783349542047973376
author Kyrölä, Kati Kristiina
Salme, Järvenpää
Tuija, Järviluoma
Tero, Irmola
Eero, Kauppinen
Arja, Häkkinen
author_facet Kyrölä, Kati Kristiina
Salme, Järvenpää
Tuija, Järviluoma
Tero, Irmola
Eero, Kauppinen
Arja, Häkkinen
author_sort Kyrölä, Kati Kristiina
collection PubMed
description BACKGROUND/AIMS: To evaluate the intra- and interrater reliability (I-IR) of sagittal spinopelvic parameters from digital full-spine plain radiographs with basic software tools in an unselected adult population with degenerative spinal complaints who were evaluated for surgery. METHODS: Forty-nine adult full-spine digital radiographs were measured twice by 3 independent observers, including an experienced spine surgeon, an experienced radiologist, and a resident orthopedic surgeon. Clinical picture archiving and communication system workstations and software tools were used and landmarks were set manually. The I-IR of the sagittal vertical axis (SVA), pelvic tilt (PT), pelvic incidence (PI), sacral slope (SS), and thoracic kyphosis in T4–T12 (TK) were assessed. RESULTS: The intrarater intraclass correlation coefficient (ICC) scores varied from 0.82 to 0.99. The interrater ICC scores ranged from 0.78 to 0.99. The intrarater standard error of measurement (SEM) values for SS, PT, PI, and TK varied from 0.8° to 5.0°, and the interrater SEM values ranged from 2.5° to 6.2°, depending on the parameter and the reading round. The I-IR SEM values for SVA varied from 2.2 to 5.7 mm and from 4.6 to 5.0 mm, respectively. Kappa values were >0.88 for all readers. The intrarater variability was the smallest for the most experienced rater. CONCLUSION: The I-IR of measuring sagittal spinopelvic parameters on digital full-spine images with basic software tools was high. Parameters consisting of several anatomic landmarks were more liable to error. Rater experience had a positive influence on reliability and repeatability. Reader experience should be assessed before accepting measurements for surgical planning and the interpretation of surgical correction during postoperative follow-up.
format Online
Article
Text
id pubmed-6104729
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Korean Spinal Neurosurgery Society
record_format MEDLINE/PubMed
spelling pubmed-61047292018-08-29 Intra- and Interrater Reliability of Sagittal Spinopelvic Parameters on Full-Spine Radiographs in Adults With Symptomatic Spinal Disorders Kyrölä, Kati Kristiina Salme, Järvenpää Tuija, Järviluoma Tero, Irmola Eero, Kauppinen Arja, Häkkinen Neurospine Original Article BACKGROUND/AIMS: To evaluate the intra- and interrater reliability (I-IR) of sagittal spinopelvic parameters from digital full-spine plain radiographs with basic software tools in an unselected adult population with degenerative spinal complaints who were evaluated for surgery. METHODS: Forty-nine adult full-spine digital radiographs were measured twice by 3 independent observers, including an experienced spine surgeon, an experienced radiologist, and a resident orthopedic surgeon. Clinical picture archiving and communication system workstations and software tools were used and landmarks were set manually. The I-IR of the sagittal vertical axis (SVA), pelvic tilt (PT), pelvic incidence (PI), sacral slope (SS), and thoracic kyphosis in T4–T12 (TK) were assessed. RESULTS: The intrarater intraclass correlation coefficient (ICC) scores varied from 0.82 to 0.99. The interrater ICC scores ranged from 0.78 to 0.99. The intrarater standard error of measurement (SEM) values for SS, PT, PI, and TK varied from 0.8° to 5.0°, and the interrater SEM values ranged from 2.5° to 6.2°, depending on the parameter and the reading round. The I-IR SEM values for SVA varied from 2.2 to 5.7 mm and from 4.6 to 5.0 mm, respectively. Kappa values were >0.88 for all readers. The intrarater variability was the smallest for the most experienced rater. CONCLUSION: The I-IR of measuring sagittal spinopelvic parameters on digital full-spine images with basic software tools was high. Parameters consisting of several anatomic landmarks were more liable to error. Rater experience had a positive influence on reliability and repeatability. Reader experience should be assessed before accepting measurements for surgical planning and the interpretation of surgical correction during postoperative follow-up. Korean Spinal Neurosurgery Society 2018-06 2018-06-19 /pmc/articles/PMC6104729/ /pubmed/29991248 http://dx.doi.org/10.14245/ns.1836054.027 Text en Copyright © 2018 by the Korean Spinal Neurosurgery Society This is an open access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Kyrölä, Kati Kristiina
Salme, Järvenpää
Tuija, Järviluoma
Tero, Irmola
Eero, Kauppinen
Arja, Häkkinen
Intra- and Interrater Reliability of Sagittal Spinopelvic Parameters on Full-Spine Radiographs in Adults With Symptomatic Spinal Disorders
title Intra- and Interrater Reliability of Sagittal Spinopelvic Parameters on Full-Spine Radiographs in Adults With Symptomatic Spinal Disorders
title_full Intra- and Interrater Reliability of Sagittal Spinopelvic Parameters on Full-Spine Radiographs in Adults With Symptomatic Spinal Disorders
title_fullStr Intra- and Interrater Reliability of Sagittal Spinopelvic Parameters on Full-Spine Radiographs in Adults With Symptomatic Spinal Disorders
title_full_unstemmed Intra- and Interrater Reliability of Sagittal Spinopelvic Parameters on Full-Spine Radiographs in Adults With Symptomatic Spinal Disorders
title_short Intra- and Interrater Reliability of Sagittal Spinopelvic Parameters on Full-Spine Radiographs in Adults With Symptomatic Spinal Disorders
title_sort intra- and interrater reliability of sagittal spinopelvic parameters on full-spine radiographs in adults with symptomatic spinal disorders
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6104729/
https://www.ncbi.nlm.nih.gov/pubmed/29991248
http://dx.doi.org/10.14245/ns.1836054.027
work_keys_str_mv AT kyrolakatikristiina intraandinterraterreliabilityofsagittalspinopelvicparametersonfullspineradiographsinadultswithsymptomaticspinaldisorders
AT salmejarvenpaa intraandinterraterreliabilityofsagittalspinopelvicparametersonfullspineradiographsinadultswithsymptomaticspinaldisorders
AT tuijajarviluoma intraandinterraterreliabilityofsagittalspinopelvicparametersonfullspineradiographsinadultswithsymptomaticspinaldisorders
AT teroirmola intraandinterraterreliabilityofsagittalspinopelvicparametersonfullspineradiographsinadultswithsymptomaticspinaldisorders
AT eerokauppinen intraandinterraterreliabilityofsagittalspinopelvicparametersonfullspineradiographsinadultswithsymptomaticspinaldisorders
AT arjahakkinen intraandinterraterreliabilityofsagittalspinopelvicparametersonfullspineradiographsinadultswithsymptomaticspinaldisorders