Cargando…

Clinical reassessment of human embryo ploidy status between cleavage and blastocyst stage by Next Generation Sequencing

One of the most important limitations of genetic testing in preimplantation embryos is embryonic mosaicism, especially when performed on D3 with only a single blastomere evaluated. Previous publications, using Array-Comparative Genomic Hybridization (a-CGH) to compare day 3 (D3) biopsies versus trop...

Descripción completa

Detalles Bibliográficos
Autores principales: Liñán, Alberto, Lawrenz, Barbara, El Khatib, Ibrahim, Bayram, Asina, Arnanz, Ana, Rubio, Carmen, Chopra, Rupali, Fatemi, Human M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6104923/
https://www.ncbi.nlm.nih.gov/pubmed/30133476
http://dx.doi.org/10.1371/journal.pone.0201652
_version_ 1783349568321093632
author Liñán, Alberto
Lawrenz, Barbara
El Khatib, Ibrahim
Bayram, Asina
Arnanz, Ana
Rubio, Carmen
Chopra, Rupali
Fatemi, Human M.
author_facet Liñán, Alberto
Lawrenz, Barbara
El Khatib, Ibrahim
Bayram, Asina
Arnanz, Ana
Rubio, Carmen
Chopra, Rupali
Fatemi, Human M.
author_sort Liñán, Alberto
collection PubMed
description One of the most important limitations of genetic testing in preimplantation embryos is embryonic mosaicism, especially when performed on D3 with only a single blastomere evaluated. Previous publications, using Array-Comparative Genomic Hybridization (a-CGH) to compare day 3 (D3) biopsies versus trophectoderm biopsies for the analysis of aneuploid embryos, showed similar high concordance rates per embryo diagnosis for D3 biopsies and trophectoderm biopsies. Next generation sequencing (NGS) was introduced lately as a new technique for preimplantation genetic testing for aneuploidies (PGT-A). Using this technique, this retrospective descriptive study evaluated the degree of the concordance of the diagnosis between preimplantation human cleavage stage (D3) and blastocyst stage (D5) embryos. Double biopsies on D3 and D5 were performed on 118 embryos, reaching blastocyst stage on D5 and had not been selected for transfer. As the fertilization law of the United Arab Emirates does not allow embryo freezing, also surplus euploid embryos after D 3 biopsy were included. Analysis of the NGS results from D3 and D5 embryo biopsies showed a total concordance rate per embryo diagnosis of 85.6% for euploid and aneuploid embryos. The concordance rates per embryo chromosomal pattern for embryo diagnosed as aneuploid at both biopsy stages was 82.2%. However, the status regarding the affected chromosomes was not identical on D3 and D5. Hence, the total concordance rate between D3 biopsy and D5 biopsy was limited to 67.8%. This current study clearly demonstrated that the concordance rates between D3 and D5 biopsies in aneuploid and euploid embryos are lower than previously reported.
format Online
Article
Text
id pubmed-6104923
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-61049232018-09-15 Clinical reassessment of human embryo ploidy status between cleavage and blastocyst stage by Next Generation Sequencing Liñán, Alberto Lawrenz, Barbara El Khatib, Ibrahim Bayram, Asina Arnanz, Ana Rubio, Carmen Chopra, Rupali Fatemi, Human M. PLoS One Research Article One of the most important limitations of genetic testing in preimplantation embryos is embryonic mosaicism, especially when performed on D3 with only a single blastomere evaluated. Previous publications, using Array-Comparative Genomic Hybridization (a-CGH) to compare day 3 (D3) biopsies versus trophectoderm biopsies for the analysis of aneuploid embryos, showed similar high concordance rates per embryo diagnosis for D3 biopsies and trophectoderm biopsies. Next generation sequencing (NGS) was introduced lately as a new technique for preimplantation genetic testing for aneuploidies (PGT-A). Using this technique, this retrospective descriptive study evaluated the degree of the concordance of the diagnosis between preimplantation human cleavage stage (D3) and blastocyst stage (D5) embryos. Double biopsies on D3 and D5 were performed on 118 embryos, reaching blastocyst stage on D5 and had not been selected for transfer. As the fertilization law of the United Arab Emirates does not allow embryo freezing, also surplus euploid embryos after D 3 biopsy were included. Analysis of the NGS results from D3 and D5 embryo biopsies showed a total concordance rate per embryo diagnosis of 85.6% for euploid and aneuploid embryos. The concordance rates per embryo chromosomal pattern for embryo diagnosed as aneuploid at both biopsy stages was 82.2%. However, the status regarding the affected chromosomes was not identical on D3 and D5. Hence, the total concordance rate between D3 biopsy and D5 biopsy was limited to 67.8%. This current study clearly demonstrated that the concordance rates between D3 and D5 biopsies in aneuploid and euploid embryos are lower than previously reported. Public Library of Science 2018-08-22 /pmc/articles/PMC6104923/ /pubmed/30133476 http://dx.doi.org/10.1371/journal.pone.0201652 Text en © 2018 Liñán et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Liñán, Alberto
Lawrenz, Barbara
El Khatib, Ibrahim
Bayram, Asina
Arnanz, Ana
Rubio, Carmen
Chopra, Rupali
Fatemi, Human M.
Clinical reassessment of human embryo ploidy status between cleavage and blastocyst stage by Next Generation Sequencing
title Clinical reassessment of human embryo ploidy status between cleavage and blastocyst stage by Next Generation Sequencing
title_full Clinical reassessment of human embryo ploidy status between cleavage and blastocyst stage by Next Generation Sequencing
title_fullStr Clinical reassessment of human embryo ploidy status between cleavage and blastocyst stage by Next Generation Sequencing
title_full_unstemmed Clinical reassessment of human embryo ploidy status between cleavage and blastocyst stage by Next Generation Sequencing
title_short Clinical reassessment of human embryo ploidy status between cleavage and blastocyst stage by Next Generation Sequencing
title_sort clinical reassessment of human embryo ploidy status between cleavage and blastocyst stage by next generation sequencing
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6104923/
https://www.ncbi.nlm.nih.gov/pubmed/30133476
http://dx.doi.org/10.1371/journal.pone.0201652
work_keys_str_mv AT linanalberto clinicalreassessmentofhumanembryoploidystatusbetweencleavageandblastocyststagebynextgenerationsequencing
AT lawrenzbarbara clinicalreassessmentofhumanembryoploidystatusbetweencleavageandblastocyststagebynextgenerationsequencing
AT elkhatibibrahim clinicalreassessmentofhumanembryoploidystatusbetweencleavageandblastocyststagebynextgenerationsequencing
AT bayramasina clinicalreassessmentofhumanembryoploidystatusbetweencleavageandblastocyststagebynextgenerationsequencing
AT arnanzana clinicalreassessmentofhumanembryoploidystatusbetweencleavageandblastocyststagebynextgenerationsequencing
AT rubiocarmen clinicalreassessmentofhumanembryoploidystatusbetweencleavageandblastocyststagebynextgenerationsequencing
AT choprarupali clinicalreassessmentofhumanembryoploidystatusbetweencleavageandblastocyststagebynextgenerationsequencing
AT fatemihumanm clinicalreassessmentofhumanembryoploidystatusbetweencleavageandblastocyststagebynextgenerationsequencing