Cargando…
Test-retest reliability and minimal detectable change scores for the short physical performance battery, one-legged standing test and timed up and go test in patients undergoing hemodialysis
Functional tests are commonly used for chronic kidney disease (CKD) patients undergoing hemodialysis (HD). However, the relative and absolute reliability of such physical performance-outcome assessments must first be determined in specific patient cohorts. The aims of this study were to assess the r...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6104925/ https://www.ncbi.nlm.nih.gov/pubmed/30133445 http://dx.doi.org/10.1371/journal.pone.0201035 |
_version_ | 1783349568761495552 |
---|---|
author | Ortega-Pérez de Villar, Lucía Martínez-Olmos, Francisco José Junqué-Jiménez, Anna Amer-Cuenca, Juan José Martínez-Gramage, Javier Mercer, Tom Segura-Ortí, Eva |
author_facet | Ortega-Pérez de Villar, Lucía Martínez-Olmos, Francisco José Junqué-Jiménez, Anna Amer-Cuenca, Juan José Martínez-Gramage, Javier Mercer, Tom Segura-Ortí, Eva |
author_sort | Ortega-Pérez de Villar, Lucía |
collection | PubMed |
description | Functional tests are commonly used for chronic kidney disease (CKD) patients undergoing hemodialysis (HD). However, the relative and absolute reliability of such physical performance-outcome assessments must first be determined in specific patient cohorts. The aims of this study were to assess the relative and the absolute reliability of the Short Physical Performance Battery (SPPB), One-Legged Stance Test (OLST), and Timed Up and Go (TUG) test, as well as the minimal detectable change (MDC) scores for these tests in CKD patients receiving HD. Seventy-one end-stage CKD patients receiving HD therapy, aged between 21 and 90 years, participated in the study. The patients completed two testing sessions one to two weeks apart and performed by the same examiner, comprising the following tests: the SPPB (n = 65), OLST (n = 62), and TUG test (n = 66). High intraclass correlation coefficients (≥0.90) were found for all the tests, suggesting that their relative reliability is excellent. The MDC scores for the 90% confidence intervals were as follows: 1.7 points for the SPPB, 11.3 seconds for the OLST, and 2.9 seconds for the TUG test. The reliability of the SPPB, OLST, and TUG test for this sample were all considered to be acceptable. The MDC data generated by these tests can be used to monitor meaningful changes in the functional capacity of the daily living-related activity of CKD patients on HD. |
format | Online Article Text |
id | pubmed-6104925 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-61049252018-09-15 Test-retest reliability and minimal detectable change scores for the short physical performance battery, one-legged standing test and timed up and go test in patients undergoing hemodialysis Ortega-Pérez de Villar, Lucía Martínez-Olmos, Francisco José Junqué-Jiménez, Anna Amer-Cuenca, Juan José Martínez-Gramage, Javier Mercer, Tom Segura-Ortí, Eva PLoS One Research Article Functional tests are commonly used for chronic kidney disease (CKD) patients undergoing hemodialysis (HD). However, the relative and absolute reliability of such physical performance-outcome assessments must first be determined in specific patient cohorts. The aims of this study were to assess the relative and the absolute reliability of the Short Physical Performance Battery (SPPB), One-Legged Stance Test (OLST), and Timed Up and Go (TUG) test, as well as the minimal detectable change (MDC) scores for these tests in CKD patients receiving HD. Seventy-one end-stage CKD patients receiving HD therapy, aged between 21 and 90 years, participated in the study. The patients completed two testing sessions one to two weeks apart and performed by the same examiner, comprising the following tests: the SPPB (n = 65), OLST (n = 62), and TUG test (n = 66). High intraclass correlation coefficients (≥0.90) were found for all the tests, suggesting that their relative reliability is excellent. The MDC scores for the 90% confidence intervals were as follows: 1.7 points for the SPPB, 11.3 seconds for the OLST, and 2.9 seconds for the TUG test. The reliability of the SPPB, OLST, and TUG test for this sample were all considered to be acceptable. The MDC data generated by these tests can be used to monitor meaningful changes in the functional capacity of the daily living-related activity of CKD patients on HD. Public Library of Science 2018-08-22 /pmc/articles/PMC6104925/ /pubmed/30133445 http://dx.doi.org/10.1371/journal.pone.0201035 Text en © 2018 Ortega-Pérez de Villar et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Ortega-Pérez de Villar, Lucía Martínez-Olmos, Francisco José Junqué-Jiménez, Anna Amer-Cuenca, Juan José Martínez-Gramage, Javier Mercer, Tom Segura-Ortí, Eva Test-retest reliability and minimal detectable change scores for the short physical performance battery, one-legged standing test and timed up and go test in patients undergoing hemodialysis |
title | Test-retest reliability and minimal detectable change scores for the short physical performance battery, one-legged standing test and timed up and go test in patients undergoing hemodialysis |
title_full | Test-retest reliability and minimal detectable change scores for the short physical performance battery, one-legged standing test and timed up and go test in patients undergoing hemodialysis |
title_fullStr | Test-retest reliability and minimal detectable change scores for the short physical performance battery, one-legged standing test and timed up and go test in patients undergoing hemodialysis |
title_full_unstemmed | Test-retest reliability and minimal detectable change scores for the short physical performance battery, one-legged standing test and timed up and go test in patients undergoing hemodialysis |
title_short | Test-retest reliability and minimal detectable change scores for the short physical performance battery, one-legged standing test and timed up and go test in patients undergoing hemodialysis |
title_sort | test-retest reliability and minimal detectable change scores for the short physical performance battery, one-legged standing test and timed up and go test in patients undergoing hemodialysis |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6104925/ https://www.ncbi.nlm.nih.gov/pubmed/30133445 http://dx.doi.org/10.1371/journal.pone.0201035 |
work_keys_str_mv | AT ortegaperezdevillarlucia testretestreliabilityandminimaldetectablechangescoresfortheshortphysicalperformancebatteryoneleggedstandingtestandtimedupandgotestinpatientsundergoinghemodialysis AT martinezolmosfranciscojose testretestreliabilityandminimaldetectablechangescoresfortheshortphysicalperformancebatteryoneleggedstandingtestandtimedupandgotestinpatientsundergoinghemodialysis AT junquejimenezanna testretestreliabilityandminimaldetectablechangescoresfortheshortphysicalperformancebatteryoneleggedstandingtestandtimedupandgotestinpatientsundergoinghemodialysis AT amercuencajuanjose testretestreliabilityandminimaldetectablechangescoresfortheshortphysicalperformancebatteryoneleggedstandingtestandtimedupandgotestinpatientsundergoinghemodialysis AT martinezgramagejavier testretestreliabilityandminimaldetectablechangescoresfortheshortphysicalperformancebatteryoneleggedstandingtestandtimedupandgotestinpatientsundergoinghemodialysis AT mercertom testretestreliabilityandminimaldetectablechangescoresfortheshortphysicalperformancebatteryoneleggedstandingtestandtimedupandgotestinpatientsundergoinghemodialysis AT seguraortieva testretestreliabilityandminimaldetectablechangescoresfortheshortphysicalperformancebatteryoneleggedstandingtestandtimedupandgotestinpatientsundergoinghemodialysis |