Cargando…

Test-retest reliability and minimal detectable change scores for the short physical performance battery, one-legged standing test and timed up and go test in patients undergoing hemodialysis

Functional tests are commonly used for chronic kidney disease (CKD) patients undergoing hemodialysis (HD). However, the relative and absolute reliability of such physical performance-outcome assessments must first be determined in specific patient cohorts. The aims of this study were to assess the r...

Descripción completa

Detalles Bibliográficos
Autores principales: Ortega-Pérez de Villar, Lucía, Martínez-Olmos, Francisco José, Junqué-Jiménez, Anna, Amer-Cuenca, Juan José, Martínez-Gramage, Javier, Mercer, Tom, Segura-Ortí, Eva
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6104925/
https://www.ncbi.nlm.nih.gov/pubmed/30133445
http://dx.doi.org/10.1371/journal.pone.0201035
_version_ 1783349568761495552
author Ortega-Pérez de Villar, Lucía
Martínez-Olmos, Francisco José
Junqué-Jiménez, Anna
Amer-Cuenca, Juan José
Martínez-Gramage, Javier
Mercer, Tom
Segura-Ortí, Eva
author_facet Ortega-Pérez de Villar, Lucía
Martínez-Olmos, Francisco José
Junqué-Jiménez, Anna
Amer-Cuenca, Juan José
Martínez-Gramage, Javier
Mercer, Tom
Segura-Ortí, Eva
author_sort Ortega-Pérez de Villar, Lucía
collection PubMed
description Functional tests are commonly used for chronic kidney disease (CKD) patients undergoing hemodialysis (HD). However, the relative and absolute reliability of such physical performance-outcome assessments must first be determined in specific patient cohorts. The aims of this study were to assess the relative and the absolute reliability of the Short Physical Performance Battery (SPPB), One-Legged Stance Test (OLST), and Timed Up and Go (TUG) test, as well as the minimal detectable change (MDC) scores for these tests in CKD patients receiving HD. Seventy-one end-stage CKD patients receiving HD therapy, aged between 21 and 90 years, participated in the study. The patients completed two testing sessions one to two weeks apart and performed by the same examiner, comprising the following tests: the SPPB (n = 65), OLST (n = 62), and TUG test (n = 66). High intraclass correlation coefficients (≥0.90) were found for all the tests, suggesting that their relative reliability is excellent. The MDC scores for the 90% confidence intervals were as follows: 1.7 points for the SPPB, 11.3 seconds for the OLST, and 2.9 seconds for the TUG test. The reliability of the SPPB, OLST, and TUG test for this sample were all considered to be acceptable. The MDC data generated by these tests can be used to monitor meaningful changes in the functional capacity of the daily living-related activity of CKD patients on HD.
format Online
Article
Text
id pubmed-6104925
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-61049252018-09-15 Test-retest reliability and minimal detectable change scores for the short physical performance battery, one-legged standing test and timed up and go test in patients undergoing hemodialysis Ortega-Pérez de Villar, Lucía Martínez-Olmos, Francisco José Junqué-Jiménez, Anna Amer-Cuenca, Juan José Martínez-Gramage, Javier Mercer, Tom Segura-Ortí, Eva PLoS One Research Article Functional tests are commonly used for chronic kidney disease (CKD) patients undergoing hemodialysis (HD). However, the relative and absolute reliability of such physical performance-outcome assessments must first be determined in specific patient cohorts. The aims of this study were to assess the relative and the absolute reliability of the Short Physical Performance Battery (SPPB), One-Legged Stance Test (OLST), and Timed Up and Go (TUG) test, as well as the minimal detectable change (MDC) scores for these tests in CKD patients receiving HD. Seventy-one end-stage CKD patients receiving HD therapy, aged between 21 and 90 years, participated in the study. The patients completed two testing sessions one to two weeks apart and performed by the same examiner, comprising the following tests: the SPPB (n = 65), OLST (n = 62), and TUG test (n = 66). High intraclass correlation coefficients (≥0.90) were found for all the tests, suggesting that their relative reliability is excellent. The MDC scores for the 90% confidence intervals were as follows: 1.7 points for the SPPB, 11.3 seconds for the OLST, and 2.9 seconds for the TUG test. The reliability of the SPPB, OLST, and TUG test for this sample were all considered to be acceptable. The MDC data generated by these tests can be used to monitor meaningful changes in the functional capacity of the daily living-related activity of CKD patients on HD. Public Library of Science 2018-08-22 /pmc/articles/PMC6104925/ /pubmed/30133445 http://dx.doi.org/10.1371/journal.pone.0201035 Text en © 2018 Ortega-Pérez de Villar et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Ortega-Pérez de Villar, Lucía
Martínez-Olmos, Francisco José
Junqué-Jiménez, Anna
Amer-Cuenca, Juan José
Martínez-Gramage, Javier
Mercer, Tom
Segura-Ortí, Eva
Test-retest reliability and minimal detectable change scores for the short physical performance battery, one-legged standing test and timed up and go test in patients undergoing hemodialysis
title Test-retest reliability and minimal detectable change scores for the short physical performance battery, one-legged standing test and timed up and go test in patients undergoing hemodialysis
title_full Test-retest reliability and minimal detectable change scores for the short physical performance battery, one-legged standing test and timed up and go test in patients undergoing hemodialysis
title_fullStr Test-retest reliability and minimal detectable change scores for the short physical performance battery, one-legged standing test and timed up and go test in patients undergoing hemodialysis
title_full_unstemmed Test-retest reliability and minimal detectable change scores for the short physical performance battery, one-legged standing test and timed up and go test in patients undergoing hemodialysis
title_short Test-retest reliability and minimal detectable change scores for the short physical performance battery, one-legged standing test and timed up and go test in patients undergoing hemodialysis
title_sort test-retest reliability and minimal detectable change scores for the short physical performance battery, one-legged standing test and timed up and go test in patients undergoing hemodialysis
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6104925/
https://www.ncbi.nlm.nih.gov/pubmed/30133445
http://dx.doi.org/10.1371/journal.pone.0201035
work_keys_str_mv AT ortegaperezdevillarlucia testretestreliabilityandminimaldetectablechangescoresfortheshortphysicalperformancebatteryoneleggedstandingtestandtimedupandgotestinpatientsundergoinghemodialysis
AT martinezolmosfranciscojose testretestreliabilityandminimaldetectablechangescoresfortheshortphysicalperformancebatteryoneleggedstandingtestandtimedupandgotestinpatientsundergoinghemodialysis
AT junquejimenezanna testretestreliabilityandminimaldetectablechangescoresfortheshortphysicalperformancebatteryoneleggedstandingtestandtimedupandgotestinpatientsundergoinghemodialysis
AT amercuencajuanjose testretestreliabilityandminimaldetectablechangescoresfortheshortphysicalperformancebatteryoneleggedstandingtestandtimedupandgotestinpatientsundergoinghemodialysis
AT martinezgramagejavier testretestreliabilityandminimaldetectablechangescoresfortheshortphysicalperformancebatteryoneleggedstandingtestandtimedupandgotestinpatientsundergoinghemodialysis
AT mercertom testretestreliabilityandminimaldetectablechangescoresfortheshortphysicalperformancebatteryoneleggedstandingtestandtimedupandgotestinpatientsundergoinghemodialysis
AT seguraortieva testretestreliabilityandminimaldetectablechangescoresfortheshortphysicalperformancebatteryoneleggedstandingtestandtimedupandgotestinpatientsundergoinghemodialysis