Cargando…
Inter- and Intraobserver reproducibility of T2 relaxation times of the discus interpubicus: A feasibility study at 3 Tesla
OBJECTIVE: To quantify standard values of the discus interpubicus in healthy subjects and to determine reliability and repeatability using T2 relaxation time measurements at 3T. METHODS: 20 asymptomatic participants (10 male, 10 female; mean age: 27.3 years ±4.1, BMI: 22.2 ±1.8) underwent a 3T Magne...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6105013/ https://www.ncbi.nlm.nih.gov/pubmed/30133521 http://dx.doi.org/10.1371/journal.pone.0202698 |
_version_ | 1783349589965799424 |
---|---|
author | Maas, Kai-Jonathan Avanesov, Maxim Laqmani, Azien Weinrich, Julius Sauer, Markus Kaul, Michael G. Adam, Gerhard Regier, Marc Behzadi, Cyrus |
author_facet | Maas, Kai-Jonathan Avanesov, Maxim Laqmani, Azien Weinrich, Julius Sauer, Markus Kaul, Michael G. Adam, Gerhard Regier, Marc Behzadi, Cyrus |
author_sort | Maas, Kai-Jonathan |
collection | PubMed |
description | OBJECTIVE: To quantify standard values of the discus interpubicus in healthy subjects and to determine reliability and repeatability using T2 relaxation time measurements at 3T. METHODS: 20 asymptomatic participants (10 male, 10 female; mean age: 27.3 years ±4.1, BMI: 22.2 ±1.8) underwent a 3T Magnetic Resonance Imaging (MRI) of the pelvic region in a supine position. We included sagittal and para-axial T2w sequences centred over the pubic symphysis in order to identify the complete discus interpubicus. For quantitative analysis, a multi-echo Turbo Spin Echo (TSE) sequence (including 12 echo times between 6.4 and 76.8 ms) was acquired and analysed by using an in-house developed quantification plugin tool (qMapIt) extending ImageJ. Two readers in consensus defined three central slices of the pubic symphysis with the greatest length. For each slice, both readers separately placed three regions-of-interest (ROI) covering the whole discus interpubicus. Both readers repeated the ROI placements in identical fashion after a four-week interval on the original MRI images. Statistical analysis included intraclass correlation coefficient (ICC), nonparametric Wilcoxon test, Fisher exact test and mean relaxation time in ms and 95% confidence intervals. RESULTS: T2 relaxation time analysis was performed for all 20 participants. In total, a mean relaxation time of all analysed segments for both observers was 48.6 (±6.3 ms), with a mean relaxation time for observer 1 of 48.7 (±6.0 ms) and for observer 2 of 48.5 ms (±6.6ms). The calculated ICC comparing inter- and intrarater reproducibility was excellent in all segments (≥0.75). CONCLUSION: T2 mapping of the discus interpubicus demonstrates good inter- and intrarater repeatability as well as reliability. Mean relaxation times were calculated with 48.6ms in healthy volunteers. |
format | Online Article Text |
id | pubmed-6105013 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-61050132018-09-15 Inter- and Intraobserver reproducibility of T2 relaxation times of the discus interpubicus: A feasibility study at 3 Tesla Maas, Kai-Jonathan Avanesov, Maxim Laqmani, Azien Weinrich, Julius Sauer, Markus Kaul, Michael G. Adam, Gerhard Regier, Marc Behzadi, Cyrus PLoS One Research Article OBJECTIVE: To quantify standard values of the discus interpubicus in healthy subjects and to determine reliability and repeatability using T2 relaxation time measurements at 3T. METHODS: 20 asymptomatic participants (10 male, 10 female; mean age: 27.3 years ±4.1, BMI: 22.2 ±1.8) underwent a 3T Magnetic Resonance Imaging (MRI) of the pelvic region in a supine position. We included sagittal and para-axial T2w sequences centred over the pubic symphysis in order to identify the complete discus interpubicus. For quantitative analysis, a multi-echo Turbo Spin Echo (TSE) sequence (including 12 echo times between 6.4 and 76.8 ms) was acquired and analysed by using an in-house developed quantification plugin tool (qMapIt) extending ImageJ. Two readers in consensus defined three central slices of the pubic symphysis with the greatest length. For each slice, both readers separately placed three regions-of-interest (ROI) covering the whole discus interpubicus. Both readers repeated the ROI placements in identical fashion after a four-week interval on the original MRI images. Statistical analysis included intraclass correlation coefficient (ICC), nonparametric Wilcoxon test, Fisher exact test and mean relaxation time in ms and 95% confidence intervals. RESULTS: T2 relaxation time analysis was performed for all 20 participants. In total, a mean relaxation time of all analysed segments for both observers was 48.6 (±6.3 ms), with a mean relaxation time for observer 1 of 48.7 (±6.0 ms) and for observer 2 of 48.5 ms (±6.6ms). The calculated ICC comparing inter- and intrarater reproducibility was excellent in all segments (≥0.75). CONCLUSION: T2 mapping of the discus interpubicus demonstrates good inter- and intrarater repeatability as well as reliability. Mean relaxation times were calculated with 48.6ms in healthy volunteers. Public Library of Science 2018-08-22 /pmc/articles/PMC6105013/ /pubmed/30133521 http://dx.doi.org/10.1371/journal.pone.0202698 Text en © 2018 Maas et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Maas, Kai-Jonathan Avanesov, Maxim Laqmani, Azien Weinrich, Julius Sauer, Markus Kaul, Michael G. Adam, Gerhard Regier, Marc Behzadi, Cyrus Inter- and Intraobserver reproducibility of T2 relaxation times of the discus interpubicus: A feasibility study at 3 Tesla |
title | Inter- and Intraobserver reproducibility of T2 relaxation times of the discus interpubicus: A feasibility study at 3 Tesla |
title_full | Inter- and Intraobserver reproducibility of T2 relaxation times of the discus interpubicus: A feasibility study at 3 Tesla |
title_fullStr | Inter- and Intraobserver reproducibility of T2 relaxation times of the discus interpubicus: A feasibility study at 3 Tesla |
title_full_unstemmed | Inter- and Intraobserver reproducibility of T2 relaxation times of the discus interpubicus: A feasibility study at 3 Tesla |
title_short | Inter- and Intraobserver reproducibility of T2 relaxation times of the discus interpubicus: A feasibility study at 3 Tesla |
title_sort | inter- and intraobserver reproducibility of t2 relaxation times of the discus interpubicus: a feasibility study at 3 tesla |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6105013/ https://www.ncbi.nlm.nih.gov/pubmed/30133521 http://dx.doi.org/10.1371/journal.pone.0202698 |
work_keys_str_mv | AT maaskaijonathan interandintraobserverreproducibilityoft2relaxationtimesofthediscusinterpubicusafeasibilitystudyat3tesla AT avanesovmaxim interandintraobserverreproducibilityoft2relaxationtimesofthediscusinterpubicusafeasibilitystudyat3tesla AT laqmaniazien interandintraobserverreproducibilityoft2relaxationtimesofthediscusinterpubicusafeasibilitystudyat3tesla AT weinrichjulius interandintraobserverreproducibilityoft2relaxationtimesofthediscusinterpubicusafeasibilitystudyat3tesla AT sauermarkus interandintraobserverreproducibilityoft2relaxationtimesofthediscusinterpubicusafeasibilitystudyat3tesla AT kaulmichaelg interandintraobserverreproducibilityoft2relaxationtimesofthediscusinterpubicusafeasibilitystudyat3tesla AT adamgerhard interandintraobserverreproducibilityoft2relaxationtimesofthediscusinterpubicusafeasibilitystudyat3tesla AT regiermarc interandintraobserverreproducibilityoft2relaxationtimesofthediscusinterpubicusafeasibilitystudyat3tesla AT behzadicyrus interandintraobserverreproducibilityoft2relaxationtimesofthediscusinterpubicusafeasibilitystudyat3tesla |