Cargando…

Troubleshooting Interstim Sacral Neuromodulation Generators to Recover Function

PURPOSE OF REVIEW: Sacral neuromodulation (SNM) is being used to treat lower urinary tract symptoms (LUTS) with growing popularity among clinicians in multiple specialties. As this therapy becomes more common in the USA and Europe, urologists will encounter more patients implanted with SNM generator...

Descripción completa

Detalles Bibliográficos
Autor principal: Powell, C. R.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer US 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6105247/
https://www.ncbi.nlm.nih.gov/pubmed/30128939
http://dx.doi.org/10.1007/s11934-018-0837-5
_version_ 1783349630085365760
author Powell, C. R.
author_facet Powell, C. R.
author_sort Powell, C. R.
collection PubMed
description PURPOSE OF REVIEW: Sacral neuromodulation (SNM) is being used to treat lower urinary tract symptoms (LUTS) with growing popularity among clinicians in multiple specialties. As this therapy becomes more common in the USA and Europe, urologists will encounter more patients implanted with SNM generators. RECENT FINDINGS: Over time, it has recently been understood that up to 53% will develop pain at the implant site as reported by Groen et al. (J Urol 186:954, 2011) and 3–38% will lose effective stimulation as reported by Al-zahrani et al. (J Urol 185:981, 2011) and White et al. (Urology 73:731, 2009). There is a paucity of troubleshooting methodology in the literature, apart from revision surgery, to salvage the SNM generator. In fact, it has been suggested that one contemporary series’ failure rate is lower than some historic series because of the ability to reprogram devices as reported by Siegel et al. (J Urol 199:229, 2018). Standard algorithms for such reprogramming efforts are lacking in the literature and may salvage some patients otherwise destined for surgical revision or addition of multimodal therapy to achieve acceptable symptom control. SUMMARY: It is possible to troubleshoot and thereby salvage many SNM generators, saving patients from surgical revision in many cases and increasing the number of patients with persistent benefit from SNM. The algorithms presented in this manuscript represent a systematic strategy for reprogramming and troubleshooting SNM generators.
format Online
Article
Text
id pubmed-6105247
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Springer US
record_format MEDLINE/PubMed
spelling pubmed-61052472018-08-30 Troubleshooting Interstim Sacral Neuromodulation Generators to Recover Function Powell, C. R. Curr Urol Rep Lower Urinary Tract Symptoms & Voiding Dysfunction (J Sandhu, Section Editor) PURPOSE OF REVIEW: Sacral neuromodulation (SNM) is being used to treat lower urinary tract symptoms (LUTS) with growing popularity among clinicians in multiple specialties. As this therapy becomes more common in the USA and Europe, urologists will encounter more patients implanted with SNM generators. RECENT FINDINGS: Over time, it has recently been understood that up to 53% will develop pain at the implant site as reported by Groen et al. (J Urol 186:954, 2011) and 3–38% will lose effective stimulation as reported by Al-zahrani et al. (J Urol 185:981, 2011) and White et al. (Urology 73:731, 2009). There is a paucity of troubleshooting methodology in the literature, apart from revision surgery, to salvage the SNM generator. In fact, it has been suggested that one contemporary series’ failure rate is lower than some historic series because of the ability to reprogram devices as reported by Siegel et al. (J Urol 199:229, 2018). Standard algorithms for such reprogramming efforts are lacking in the literature and may salvage some patients otherwise destined for surgical revision or addition of multimodal therapy to achieve acceptable symptom control. SUMMARY: It is possible to troubleshoot and thereby salvage many SNM generators, saving patients from surgical revision in many cases and increasing the number of patients with persistent benefit from SNM. The algorithms presented in this manuscript represent a systematic strategy for reprogramming and troubleshooting SNM generators. Springer US 2018-08-20 2018 /pmc/articles/PMC6105247/ /pubmed/30128939 http://dx.doi.org/10.1007/s11934-018-0837-5 Text en © The Author(s) 2018 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Lower Urinary Tract Symptoms & Voiding Dysfunction (J Sandhu, Section Editor)
Powell, C. R.
Troubleshooting Interstim Sacral Neuromodulation Generators to Recover Function
title Troubleshooting Interstim Sacral Neuromodulation Generators to Recover Function
title_full Troubleshooting Interstim Sacral Neuromodulation Generators to Recover Function
title_fullStr Troubleshooting Interstim Sacral Neuromodulation Generators to Recover Function
title_full_unstemmed Troubleshooting Interstim Sacral Neuromodulation Generators to Recover Function
title_short Troubleshooting Interstim Sacral Neuromodulation Generators to Recover Function
title_sort troubleshooting interstim sacral neuromodulation generators to recover function
topic Lower Urinary Tract Symptoms & Voiding Dysfunction (J Sandhu, Section Editor)
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6105247/
https://www.ncbi.nlm.nih.gov/pubmed/30128939
http://dx.doi.org/10.1007/s11934-018-0837-5
work_keys_str_mv AT powellcr troubleshootinginterstimsacralneuromodulationgeneratorstorecoverfunction