Endoscopy- and Monitored Anesthesia Care-Assisted High-Resolution Impedance Manometry Improves Clinical Management

BACKGROUND: High-resolution impedance manometry (HRiM) is the test of choice to diagnose esophageal motility disorders and is particularly useful for identifying achalasia subtypes, which often guide therapy. HRiM is typically performed without sedation in the office setting. However, a substantial...

Descripción completa

Detalles Bibliográficos
Autores principales: Christian, Kaci E., Morris, John D., Xie, Guofeng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6106847/
https://www.ncbi.nlm.nih.gov/pubmed/30174967
http://dx.doi.org/10.1155/2018/9720243
_version_ 1783349856824197120
author Christian, Kaci E.
Morris, John D.
Xie, Guofeng
author_facet Christian, Kaci E.
Morris, John D.
Xie, Guofeng
author_sort Christian, Kaci E.
collection PubMed
description BACKGROUND: High-resolution impedance manometry (HRiM) is the test of choice to diagnose esophageal motility disorders and is particularly useful for identifying achalasia subtypes, which often guide therapy. HRiM is typically performed without sedation in the office setting. However, a substantial number of patients fail this approach. We report our single-center experience on endoscopy-assisted HRiM under monitored anesthesia care (MAC) in adults to demonstrate the feasibility and effectiveness of this approach. METHODS: Patients who had failed prior HRiM attempts received propofol under MAC. Patients then underwent an upper endoscopy, followed immediately by passage of a Diversateck HRiM motility catheter through the nares and under direct visualization into the stomach, often using the tip of the endoscope to guide the catheter. We then awakened the patients and asked them to perform 10 saline swallows. RESULTS: We successfully completed HRiM studies in 14 consecutive patients. Six patients had achalasia; two had esophagogastric junction outflow obstruction; two had absent contractility; one had distal esophageal spasm; one had ineffective esophageal motility; and one had a normal study. The majority of these patients were treated successfully with targeted interventions, including per oral endoscopic myotomy, gastrostomy, botox injection, medical therapy, and dietary modifications.
format Online
Article
Text
id pubmed-6106847
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-61068472018-09-02 Endoscopy- and Monitored Anesthesia Care-Assisted High-Resolution Impedance Manometry Improves Clinical Management Christian, Kaci E. Morris, John D. Xie, Guofeng Case Rep Gastrointest Med Case Report BACKGROUND: High-resolution impedance manometry (HRiM) is the test of choice to diagnose esophageal motility disorders and is particularly useful for identifying achalasia subtypes, which often guide therapy. HRiM is typically performed without sedation in the office setting. However, a substantial number of patients fail this approach. We report our single-center experience on endoscopy-assisted HRiM under monitored anesthesia care (MAC) in adults to demonstrate the feasibility and effectiveness of this approach. METHODS: Patients who had failed prior HRiM attempts received propofol under MAC. Patients then underwent an upper endoscopy, followed immediately by passage of a Diversateck HRiM motility catheter through the nares and under direct visualization into the stomach, often using the tip of the endoscope to guide the catheter. We then awakened the patients and asked them to perform 10 saline swallows. RESULTS: We successfully completed HRiM studies in 14 consecutive patients. Six patients had achalasia; two had esophagogastric junction outflow obstruction; two had absent contractility; one had distal esophageal spasm; one had ineffective esophageal motility; and one had a normal study. The majority of these patients were treated successfully with targeted interventions, including per oral endoscopic myotomy, gastrostomy, botox injection, medical therapy, and dietary modifications. Hindawi 2018-08-07 /pmc/articles/PMC6106847/ /pubmed/30174967 http://dx.doi.org/10.1155/2018/9720243 Text en Copyright © 2018 Kaci E. Christian et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Christian, Kaci E.
Morris, John D.
Xie, Guofeng
Endoscopy- and Monitored Anesthesia Care-Assisted High-Resolution Impedance Manometry Improves Clinical Management
title Endoscopy- and Monitored Anesthesia Care-Assisted High-Resolution Impedance Manometry Improves Clinical Management
title_full Endoscopy- and Monitored Anesthesia Care-Assisted High-Resolution Impedance Manometry Improves Clinical Management
title_fullStr Endoscopy- and Monitored Anesthesia Care-Assisted High-Resolution Impedance Manometry Improves Clinical Management
title_full_unstemmed Endoscopy- and Monitored Anesthesia Care-Assisted High-Resolution Impedance Manometry Improves Clinical Management
title_short Endoscopy- and Monitored Anesthesia Care-Assisted High-Resolution Impedance Manometry Improves Clinical Management
title_sort endoscopy- and monitored anesthesia care-assisted high-resolution impedance manometry improves clinical management
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6106847/
https://www.ncbi.nlm.nih.gov/pubmed/30174967
http://dx.doi.org/10.1155/2018/9720243
work_keys_str_mv AT christiankacie endoscopyandmonitoredanesthesiacareassistedhighresolutionimpedancemanometryimprovesclinicalmanagement
AT morrisjohnd endoscopyandmonitoredanesthesiacareassistedhighresolutionimpedancemanometryimprovesclinicalmanagement
AT xieguofeng endoscopyandmonitoredanesthesiacareassistedhighresolutionimpedancemanometryimprovesclinicalmanagement