Cargando…
A comparative study of structural, functional and circulatory parameters in glaucoma diagnostics
PURPOSE: To compare the diagnostic accuracy of structural parameters, vessel density (VD) measured by optical coherence tomography angiography (OCTA), and electrophysiological testing in diagnosis of primary open-angle glaucoma (POAG). METHODS: 35 healthy participants and 90 POAG subjects underwent...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6107119/ https://www.ncbi.nlm.nih.gov/pubmed/30138396 http://dx.doi.org/10.1371/journal.pone.0201599 |
_version_ | 1783349913155796992 |
---|---|
author | Kurysheva, Natalia Ivanovna Maslova, Ekaterina Vladimirovna Zolnikova, Inna Vladimirovna Fomin, Alexey Valentinovich Lagutin, Mikhail Borisovich |
author_facet | Kurysheva, Natalia Ivanovna Maslova, Ekaterina Vladimirovna Zolnikova, Inna Vladimirovna Fomin, Alexey Valentinovich Lagutin, Mikhail Borisovich |
author_sort | Kurysheva, Natalia Ivanovna |
collection | PubMed |
description | PURPOSE: To compare the diagnostic accuracy of structural parameters, vessel density (VD) measured by optical coherence tomography angiography (OCTA), and electrophysiological testing in diagnosis of primary open-angle glaucoma (POAG). METHODS: 35 healthy participants and 90 POAG subjects underwent the measurement of whole image en face (wi) VD in the disc/peripapillary region and macula, the retinal nerve fiber layer (RNFL), and the average thickness of ganglion cell complex (GCC), pattern electroretinograms and pattern visual evoked potentials. The area under the receiver operating characteristic curve (AUC) was assessed for each parameter to differentiate early POAG from healthy eyes and between the POAG stages. RESULTS: To distinguish early POAG from healthy eyes, the parameters with the highest AUC were detected: P50 amplitude of transient pattern electroretinogram, 1° (AUC 0.93, p = 0.002), P1 component of steady-state pattern electroretinogram (AUC 0.92, p = 0.003), P100 amplitude of pattern visual evoked potential, 1° (AUC 0.84, p = 0.013), wiVD macula superficial (AUC 0.80, p = 0.001), wiVD Disc (AUC 0.74, p = 0.016), GCC (AUC 0.74, p = 0.016) and to distinguish early POAG from the moderate to severe POAG: inferotemporal peripapillary VD (AUC 0.94, p < 0.0001) and focal loss volume of GCC (AUC 0.92, p < 0, 001). CONCLUSIONS: Our results demonstrate the importance of measuring the microcirculation parameters in the macular area along with PERGs and PVEPs for the early detection of glaucoma. VD in the inferotemporal sector of the peripapillary retina and focal loss volume of the GCC are important for monitoring of the disease. The inclusion of OCTA, PERGs and PVEPs in glaucoma diagnostics may improve its early detection and monitoring. |
format | Online Article Text |
id | pubmed-6107119 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-61071192018-08-30 A comparative study of structural, functional and circulatory parameters in glaucoma diagnostics Kurysheva, Natalia Ivanovna Maslova, Ekaterina Vladimirovna Zolnikova, Inna Vladimirovna Fomin, Alexey Valentinovich Lagutin, Mikhail Borisovich PLoS One Research Article PURPOSE: To compare the diagnostic accuracy of structural parameters, vessel density (VD) measured by optical coherence tomography angiography (OCTA), and electrophysiological testing in diagnosis of primary open-angle glaucoma (POAG). METHODS: 35 healthy participants and 90 POAG subjects underwent the measurement of whole image en face (wi) VD in the disc/peripapillary region and macula, the retinal nerve fiber layer (RNFL), and the average thickness of ganglion cell complex (GCC), pattern electroretinograms and pattern visual evoked potentials. The area under the receiver operating characteristic curve (AUC) was assessed for each parameter to differentiate early POAG from healthy eyes and between the POAG stages. RESULTS: To distinguish early POAG from healthy eyes, the parameters with the highest AUC were detected: P50 amplitude of transient pattern electroretinogram, 1° (AUC 0.93, p = 0.002), P1 component of steady-state pattern electroretinogram (AUC 0.92, p = 0.003), P100 amplitude of pattern visual evoked potential, 1° (AUC 0.84, p = 0.013), wiVD macula superficial (AUC 0.80, p = 0.001), wiVD Disc (AUC 0.74, p = 0.016), GCC (AUC 0.74, p = 0.016) and to distinguish early POAG from the moderate to severe POAG: inferotemporal peripapillary VD (AUC 0.94, p < 0.0001) and focal loss volume of GCC (AUC 0.92, p < 0, 001). CONCLUSIONS: Our results demonstrate the importance of measuring the microcirculation parameters in the macular area along with PERGs and PVEPs for the early detection of glaucoma. VD in the inferotemporal sector of the peripapillary retina and focal loss volume of the GCC are important for monitoring of the disease. The inclusion of OCTA, PERGs and PVEPs in glaucoma diagnostics may improve its early detection and monitoring. Public Library of Science 2018-08-23 /pmc/articles/PMC6107119/ /pubmed/30138396 http://dx.doi.org/10.1371/journal.pone.0201599 Text en © 2018 Kurysheva et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Kurysheva, Natalia Ivanovna Maslova, Ekaterina Vladimirovna Zolnikova, Inna Vladimirovna Fomin, Alexey Valentinovich Lagutin, Mikhail Borisovich A comparative study of structural, functional and circulatory parameters in glaucoma diagnostics |
title | A comparative study of structural, functional and circulatory parameters in glaucoma diagnostics |
title_full | A comparative study of structural, functional and circulatory parameters in glaucoma diagnostics |
title_fullStr | A comparative study of structural, functional and circulatory parameters in glaucoma diagnostics |
title_full_unstemmed | A comparative study of structural, functional and circulatory parameters in glaucoma diagnostics |
title_short | A comparative study of structural, functional and circulatory parameters in glaucoma diagnostics |
title_sort | comparative study of structural, functional and circulatory parameters in glaucoma diagnostics |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6107119/ https://www.ncbi.nlm.nih.gov/pubmed/30138396 http://dx.doi.org/10.1371/journal.pone.0201599 |
work_keys_str_mv | AT kuryshevanataliaivanovna acomparativestudyofstructuralfunctionalandcirculatoryparametersinglaucomadiagnostics AT maslovaekaterinavladimirovna acomparativestudyofstructuralfunctionalandcirculatoryparametersinglaucomadiagnostics AT zolnikovainnavladimirovna acomparativestudyofstructuralfunctionalandcirculatoryparametersinglaucomadiagnostics AT fominalexeyvalentinovich acomparativestudyofstructuralfunctionalandcirculatoryparametersinglaucomadiagnostics AT lagutinmikhailborisovich acomparativestudyofstructuralfunctionalandcirculatoryparametersinglaucomadiagnostics AT kuryshevanataliaivanovna comparativestudyofstructuralfunctionalandcirculatoryparametersinglaucomadiagnostics AT maslovaekaterinavladimirovna comparativestudyofstructuralfunctionalandcirculatoryparametersinglaucomadiagnostics AT zolnikovainnavladimirovna comparativestudyofstructuralfunctionalandcirculatoryparametersinglaucomadiagnostics AT fominalexeyvalentinovich comparativestudyofstructuralfunctionalandcirculatoryparametersinglaucomadiagnostics AT lagutinmikhailborisovich comparativestudyofstructuralfunctionalandcirculatoryparametersinglaucomadiagnostics |