Cargando…
Percutaneous transmitral balloon commissurotomy using a single balloon with arteriovenous loop stabilisation: an alternative when there is no Inoue balloon
BACKGROUND: The Inoue balloon technique is the standard technique for mitral valve balloon commissurotomy at this stage. However, the hardware for this technique is expensive and may not always be available in resource-limited settings. OBJECTIVES: This article reports our experience with percutaneo...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Clinics Cardive Publishing
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6107808/ https://www.ncbi.nlm.nih.gov/pubmed/29457827 http://dx.doi.org/10.5830/CVJA-2018-010 |
_version_ | 1783350033113939968 |
---|---|
author | Endale, Tefera Mohamed, Leye Joaquim, Miró Patrick, Garceau Denis, Bouchard |
author_facet | Endale, Tefera Mohamed, Leye Joaquim, Miró Patrick, Garceau Denis, Bouchard |
author_sort | Endale, Tefera |
collection | PubMed |
description | BACKGROUND: The Inoue balloon technique is the standard technique for mitral valve balloon commissurotomy at this stage. However, the hardware for this technique is expensive and may not always be available in resource-limited settings. OBJECTIVES: This article reports our experience with percutaneous transmitral balloon commissurotomy using a single balloon (Nucleus) with arteriovenous loop stabilisation. METHODS: Eleven young patients, aged 12–26 years and weighing 23–48 kg, underwent transmitral balloon commissurotomy using the described technique at our centre from April to May 2014. RESULTS: Mean fluoroscopy time was 22.6 ± 6.4 min (18.5– 30.0). Mean transmitral gradient decreased from 24.1 ± 5.9 (16–35) to 6.6 ± 3.8 (3–14) mmHg, as measured on transoesophageal echocardiography. Mean mitral valve area increased from 0.69 ± 0.13 cm(2) (range 0.5–0.9) before dilation to 1.44 ± 0.25 cm(2) (1.1–1.9) after dilation (p < 0.001). Mean estimated pulmonary artery systolic pressure decreased from 110.0 ± 35 mmHg (75–170) before dilation to 28.0 ± 14.4 mmHg (range 10–60) after dilation. CONCLUSION: Our modified Nucleus balloon technique for mitral valve dilation in young patients with mitral stenosis is effective and safe. The technique differs from other over-thewire techniques in that it avoids placing stiff wire in the left ventricle. It also offers better balloon stability and control owing to the arteriovenous loop. This technique may be easier for use by paediatric interventionists who might not be familiar with the Inoue balloon technique. |
format | Online Article Text |
id | pubmed-6107808 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Clinics Cardive Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-61078082018-11-30 Percutaneous transmitral balloon commissurotomy using a single balloon with arteriovenous loop stabilisation: an alternative when there is no Inoue balloon Endale, Tefera Mohamed, Leye Joaquim, Miró Patrick, Garceau Denis, Bouchard Cardiovasc J Afr Cardiovascular Topics BACKGROUND: The Inoue balloon technique is the standard technique for mitral valve balloon commissurotomy at this stage. However, the hardware for this technique is expensive and may not always be available in resource-limited settings. OBJECTIVES: This article reports our experience with percutaneous transmitral balloon commissurotomy using a single balloon (Nucleus) with arteriovenous loop stabilisation. METHODS: Eleven young patients, aged 12–26 years and weighing 23–48 kg, underwent transmitral balloon commissurotomy using the described technique at our centre from April to May 2014. RESULTS: Mean fluoroscopy time was 22.6 ± 6.4 min (18.5– 30.0). Mean transmitral gradient decreased from 24.1 ± 5.9 (16–35) to 6.6 ± 3.8 (3–14) mmHg, as measured on transoesophageal echocardiography. Mean mitral valve area increased from 0.69 ± 0.13 cm(2) (range 0.5–0.9) before dilation to 1.44 ± 0.25 cm(2) (1.1–1.9) after dilation (p < 0.001). Mean estimated pulmonary artery systolic pressure decreased from 110.0 ± 35 mmHg (75–170) before dilation to 28.0 ± 14.4 mmHg (range 10–60) after dilation. CONCLUSION: Our modified Nucleus balloon technique for mitral valve dilation in young patients with mitral stenosis is effective and safe. The technique differs from other over-thewire techniques in that it avoids placing stiff wire in the left ventricle. It also offers better balloon stability and control owing to the arteriovenous loop. This technique may be easier for use by paediatric interventionists who might not be familiar with the Inoue balloon technique. Clinics Cardive Publishing 2018 /pmc/articles/PMC6107808/ /pubmed/29457827 http://dx.doi.org/10.5830/CVJA-2018-010 Text en Copyright © 2015 Clinics Cardive Publishing http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Cardiovascular Topics Endale, Tefera Mohamed, Leye Joaquim, Miró Patrick, Garceau Denis, Bouchard Percutaneous transmitral balloon commissurotomy using a single balloon with arteriovenous loop stabilisation: an alternative when there is no Inoue balloon |
title | Percutaneous transmitral balloon commissurotomy using a single balloon with arteriovenous loop stabilisation: an alternative when there is no Inoue balloon |
title_full | Percutaneous transmitral balloon commissurotomy using a single balloon with arteriovenous loop stabilisation: an alternative when there is no Inoue balloon |
title_fullStr | Percutaneous transmitral balloon commissurotomy using a single balloon with arteriovenous loop stabilisation: an alternative when there is no Inoue balloon |
title_full_unstemmed | Percutaneous transmitral balloon commissurotomy using a single balloon with arteriovenous loop stabilisation: an alternative when there is no Inoue balloon |
title_short | Percutaneous transmitral balloon commissurotomy using a single balloon with arteriovenous loop stabilisation: an alternative when there is no Inoue balloon |
title_sort | percutaneous transmitral balloon commissurotomy using a single balloon with arteriovenous loop stabilisation: an alternative when there is no inoue balloon |
topic | Cardiovascular Topics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6107808/ https://www.ncbi.nlm.nih.gov/pubmed/29457827 http://dx.doi.org/10.5830/CVJA-2018-010 |
work_keys_str_mv | AT endaletefera percutaneoustransmitralballooncommissurotomyusingasingleballoonwitharteriovenousloopstabilisationanalternativewhenthereisnoinoueballoon AT mohamedleye percutaneoustransmitralballooncommissurotomyusingasingleballoonwitharteriovenousloopstabilisationanalternativewhenthereisnoinoueballoon AT joaquimmiro percutaneoustransmitralballooncommissurotomyusingasingleballoonwitharteriovenousloopstabilisationanalternativewhenthereisnoinoueballoon AT patrickgarceau percutaneoustransmitralballooncommissurotomyusingasingleballoonwitharteriovenousloopstabilisationanalternativewhenthereisnoinoueballoon AT denisbouchard percutaneoustransmitralballooncommissurotomyusingasingleballoonwitharteriovenousloopstabilisationanalternativewhenthereisnoinoueballoon |