Cargando…
Evaluation of seven optical clearing methods in mouse brain
Recently, a variety of tissue optical clearing techniques have been developed to reduce light scattering for imaging deeper and three-dimensional reconstruction of tissue structures. Combined with optical imaging techniques and diverse labeling methods, these clearing methods have significantly prom...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Society of Photo-Optical Instrumentation Engineers
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6109056/ https://www.ncbi.nlm.nih.gov/pubmed/30155510 http://dx.doi.org/10.1117/1.NPh.5.3.035007 |
_version_ | 1783350248011202560 |
---|---|
author | Wan, Peng Zhu, Jingtan Xu, Jianyi Li, Yusha Yu, Tingting Zhu, Dan |
author_facet | Wan, Peng Zhu, Jingtan Xu, Jianyi Li, Yusha Yu, Tingting Zhu, Dan |
author_sort | Wan, Peng |
collection | PubMed |
description | Recently, a variety of tissue optical clearing techniques have been developed to reduce light scattering for imaging deeper and three-dimensional reconstruction of tissue structures. Combined with optical imaging techniques and diverse labeling methods, these clearing methods have significantly promoted the development of neuroscience. Each of them has its own characteristics with certain advantages and disadvantages. Though there are some comparison results, the clearing methods covered are limited and the evaluation indices lack uniformity, which made it difficult to select a best-fit protocol from numerous methods for clearing in practical applications. Hence, it is necessary to systematically assess and compare these clearing methods. We evaluated the performance of seven typical clearing methods, including 3-D imaging of solvent-cleared organs (3DISCO), ultimate DISCO (uDISCO), see deep brain (SeeDB), ScaleS, [Formula: see text] , clear, unobstructed brain imaging cocktails and computational analysis, and passive CLARITY technique (PACT), on mouse brain samples. First, we compared the clearing effect and clearing time as well as size deformation on brain tissues. Further, we evaluated the fluorescence preservation and the increase of imaging depth induced by different methods. The results showed that 3DISCO, uDISCO, and PACT possessed excellent clearing capability on mouse brains, ScaleS and SeeDB rendered moderate transparency, whereas [Formula: see text] performed the worst. uDISCO and 3DISCO induced substantial size reduction on brain sections, and PACT expanded the mouse brain most seriously. Among those methods, ScaleS performed best on fluorescence retention, 3DISCO induced the biggest decline of the fluorescence. PACT achieved the highest increase of imaging depth, and SeeDB and [Formula: see text] possessed the shallowest imaging depth. This study is expected to provide important reference for users in choosing the most suitable brain optical clearing method. |
format | Online Article Text |
id | pubmed-6109056 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Society of Photo-Optical Instrumentation Engineers |
record_format | MEDLINE/PubMed |
spelling | pubmed-61090562019-08-25 Evaluation of seven optical clearing methods in mouse brain Wan, Peng Zhu, Jingtan Xu, Jianyi Li, Yusha Yu, Tingting Zhu, Dan Neurophotonics Research Papers Recently, a variety of tissue optical clearing techniques have been developed to reduce light scattering for imaging deeper and three-dimensional reconstruction of tissue structures. Combined with optical imaging techniques and diverse labeling methods, these clearing methods have significantly promoted the development of neuroscience. Each of them has its own characteristics with certain advantages and disadvantages. Though there are some comparison results, the clearing methods covered are limited and the evaluation indices lack uniformity, which made it difficult to select a best-fit protocol from numerous methods for clearing in practical applications. Hence, it is necessary to systematically assess and compare these clearing methods. We evaluated the performance of seven typical clearing methods, including 3-D imaging of solvent-cleared organs (3DISCO), ultimate DISCO (uDISCO), see deep brain (SeeDB), ScaleS, [Formula: see text] , clear, unobstructed brain imaging cocktails and computational analysis, and passive CLARITY technique (PACT), on mouse brain samples. First, we compared the clearing effect and clearing time as well as size deformation on brain tissues. Further, we evaluated the fluorescence preservation and the increase of imaging depth induced by different methods. The results showed that 3DISCO, uDISCO, and PACT possessed excellent clearing capability on mouse brains, ScaleS and SeeDB rendered moderate transparency, whereas [Formula: see text] performed the worst. uDISCO and 3DISCO induced substantial size reduction on brain sections, and PACT expanded the mouse brain most seriously. Among those methods, ScaleS performed best on fluorescence retention, 3DISCO induced the biggest decline of the fluorescence. PACT achieved the highest increase of imaging depth, and SeeDB and [Formula: see text] possessed the shallowest imaging depth. This study is expected to provide important reference for users in choosing the most suitable brain optical clearing method. Society of Photo-Optical Instrumentation Engineers 2018-08-25 2018-07 /pmc/articles/PMC6109056/ /pubmed/30155510 http://dx.doi.org/10.1117/1.NPh.5.3.035007 Text en © The Authors. https://creativecommons.org/licenses/by/3.0/ Published by SPIE under a Creative Commons Attribution 3.0 Unported License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI. |
spellingShingle | Research Papers Wan, Peng Zhu, Jingtan Xu, Jianyi Li, Yusha Yu, Tingting Zhu, Dan Evaluation of seven optical clearing methods in mouse brain |
title | Evaluation of seven optical clearing methods in mouse brain |
title_full | Evaluation of seven optical clearing methods in mouse brain |
title_fullStr | Evaluation of seven optical clearing methods in mouse brain |
title_full_unstemmed | Evaluation of seven optical clearing methods in mouse brain |
title_short | Evaluation of seven optical clearing methods in mouse brain |
title_sort | evaluation of seven optical clearing methods in mouse brain |
topic | Research Papers |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6109056/ https://www.ncbi.nlm.nih.gov/pubmed/30155510 http://dx.doi.org/10.1117/1.NPh.5.3.035007 |
work_keys_str_mv | AT wanpeng evaluationofsevenopticalclearingmethodsinmousebrain AT zhujingtan evaluationofsevenopticalclearingmethodsinmousebrain AT xujianyi evaluationofsevenopticalclearingmethodsinmousebrain AT liyusha evaluationofsevenopticalclearingmethodsinmousebrain AT yutingting evaluationofsevenopticalclearingmethodsinmousebrain AT zhudan evaluationofsevenopticalclearingmethodsinmousebrain |