Cargando…

Evaluation of seven optical clearing methods in mouse brain

Recently, a variety of tissue optical clearing techniques have been developed to reduce light scattering for imaging deeper and three-dimensional reconstruction of tissue structures. Combined with optical imaging techniques and diverse labeling methods, these clearing methods have significantly prom...

Descripción completa

Detalles Bibliográficos
Autores principales: Wan, Peng, Zhu, Jingtan, Xu, Jianyi, Li, Yusha, Yu, Tingting, Zhu, Dan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Society of Photo-Optical Instrumentation Engineers 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6109056/
https://www.ncbi.nlm.nih.gov/pubmed/30155510
http://dx.doi.org/10.1117/1.NPh.5.3.035007
_version_ 1783350248011202560
author Wan, Peng
Zhu, Jingtan
Xu, Jianyi
Li, Yusha
Yu, Tingting
Zhu, Dan
author_facet Wan, Peng
Zhu, Jingtan
Xu, Jianyi
Li, Yusha
Yu, Tingting
Zhu, Dan
author_sort Wan, Peng
collection PubMed
description Recently, a variety of tissue optical clearing techniques have been developed to reduce light scattering for imaging deeper and three-dimensional reconstruction of tissue structures. Combined with optical imaging techniques and diverse labeling methods, these clearing methods have significantly promoted the development of neuroscience. Each of them has its own characteristics with certain advantages and disadvantages. Though there are some comparison results, the clearing methods covered are limited and the evaluation indices lack uniformity, which made it difficult to select a best-fit protocol from numerous methods for clearing in practical applications. Hence, it is necessary to systematically assess and compare these clearing methods. We evaluated the performance of seven typical clearing methods, including 3-D imaging of solvent-cleared organs (3DISCO), ultimate DISCO (uDISCO), see deep brain (SeeDB), ScaleS, [Formula: see text] , clear, unobstructed brain imaging cocktails and computational analysis, and passive CLARITY technique (PACT), on mouse brain samples. First, we compared the clearing effect and clearing time as well as size deformation on brain tissues. Further, we evaluated the fluorescence preservation and the increase of imaging depth induced by different methods. The results showed that 3DISCO, uDISCO, and PACT possessed excellent clearing capability on mouse brains, ScaleS and SeeDB rendered moderate transparency, whereas [Formula: see text] performed the worst. uDISCO and 3DISCO induced substantial size reduction on brain sections, and PACT expanded the mouse brain most seriously. Among those methods, ScaleS performed best on fluorescence retention, 3DISCO induced the biggest decline of the fluorescence. PACT achieved the highest increase of imaging depth, and SeeDB and [Formula: see text] possessed the shallowest imaging depth. This study is expected to provide important reference for users in choosing the most suitable brain optical clearing method.
format Online
Article
Text
id pubmed-6109056
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Society of Photo-Optical Instrumentation Engineers
record_format MEDLINE/PubMed
spelling pubmed-61090562019-08-25 Evaluation of seven optical clearing methods in mouse brain Wan, Peng Zhu, Jingtan Xu, Jianyi Li, Yusha Yu, Tingting Zhu, Dan Neurophotonics Research Papers Recently, a variety of tissue optical clearing techniques have been developed to reduce light scattering for imaging deeper and three-dimensional reconstruction of tissue structures. Combined with optical imaging techniques and diverse labeling methods, these clearing methods have significantly promoted the development of neuroscience. Each of them has its own characteristics with certain advantages and disadvantages. Though there are some comparison results, the clearing methods covered are limited and the evaluation indices lack uniformity, which made it difficult to select a best-fit protocol from numerous methods for clearing in practical applications. Hence, it is necessary to systematically assess and compare these clearing methods. We evaluated the performance of seven typical clearing methods, including 3-D imaging of solvent-cleared organs (3DISCO), ultimate DISCO (uDISCO), see deep brain (SeeDB), ScaleS, [Formula: see text] , clear, unobstructed brain imaging cocktails and computational analysis, and passive CLARITY technique (PACT), on mouse brain samples. First, we compared the clearing effect and clearing time as well as size deformation on brain tissues. Further, we evaluated the fluorescence preservation and the increase of imaging depth induced by different methods. The results showed that 3DISCO, uDISCO, and PACT possessed excellent clearing capability on mouse brains, ScaleS and SeeDB rendered moderate transparency, whereas [Formula: see text] performed the worst. uDISCO and 3DISCO induced substantial size reduction on brain sections, and PACT expanded the mouse brain most seriously. Among those methods, ScaleS performed best on fluorescence retention, 3DISCO induced the biggest decline of the fluorescence. PACT achieved the highest increase of imaging depth, and SeeDB and [Formula: see text] possessed the shallowest imaging depth. This study is expected to provide important reference for users in choosing the most suitable brain optical clearing method. Society of Photo-Optical Instrumentation Engineers 2018-08-25 2018-07 /pmc/articles/PMC6109056/ /pubmed/30155510 http://dx.doi.org/10.1117/1.NPh.5.3.035007 Text en © The Authors. https://creativecommons.org/licenses/by/3.0/ Published by SPIE under a Creative Commons Attribution 3.0 Unported License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI.
spellingShingle Research Papers
Wan, Peng
Zhu, Jingtan
Xu, Jianyi
Li, Yusha
Yu, Tingting
Zhu, Dan
Evaluation of seven optical clearing methods in mouse brain
title Evaluation of seven optical clearing methods in mouse brain
title_full Evaluation of seven optical clearing methods in mouse brain
title_fullStr Evaluation of seven optical clearing methods in mouse brain
title_full_unstemmed Evaluation of seven optical clearing methods in mouse brain
title_short Evaluation of seven optical clearing methods in mouse brain
title_sort evaluation of seven optical clearing methods in mouse brain
topic Research Papers
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6109056/
https://www.ncbi.nlm.nih.gov/pubmed/30155510
http://dx.doi.org/10.1117/1.NPh.5.3.035007
work_keys_str_mv AT wanpeng evaluationofsevenopticalclearingmethodsinmousebrain
AT zhujingtan evaluationofsevenopticalclearingmethodsinmousebrain
AT xujianyi evaluationofsevenopticalclearingmethodsinmousebrain
AT liyusha evaluationofsevenopticalclearingmethodsinmousebrain
AT yutingting evaluationofsevenopticalclearingmethodsinmousebrain
AT zhudan evaluationofsevenopticalclearingmethodsinmousebrain