Cargando…

A Patient-Independent Significance Test by Means of False-Positive Rates in Selected Correlation Analysis of Brain Multimodal Monitoring Data

Recently, we introduced a mathematical toolkit called selected correlation analysis (sca) that reliably detects negative and positive correlations between arterial blood pressure (ABP) and intracranial pressure (ICP) data, recorded during multimodal monitoring, in a time-resolved way. As has been sh...

Descripción completa

Detalles Bibliográficos
Autores principales: Faltermeier, Rupert, Proescholdt, Martin A., Wolf, Stefan, Bele, Sylvia, Brawanski, Alexander
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6109537/
https://www.ncbi.nlm.nih.gov/pubmed/30159004
http://dx.doi.org/10.1155/2018/6821893
_version_ 1783350343069859840
author Faltermeier, Rupert
Proescholdt, Martin A.
Wolf, Stefan
Bele, Sylvia
Brawanski, Alexander
author_facet Faltermeier, Rupert
Proescholdt, Martin A.
Wolf, Stefan
Bele, Sylvia
Brawanski, Alexander
author_sort Faltermeier, Rupert
collection PubMed
description Recently, we introduced a mathematical toolkit called selected correlation analysis (sca) that reliably detects negative and positive correlations between arterial blood pressure (ABP) and intracranial pressure (ICP) data, recorded during multimodal monitoring, in a time-resolved way. As has been shown with the aid of a mathematical model of cerebral perfusion, such correlations reflect impaired autoregulation and reduced intracranial compliance in patients with critical neurological diseases. Sca calculates a Fourier transform-based index called selected correlation (sc) that reflects the strength of correlation between the input data and simultaneously an index called mean Hilbert phase difference (mhpd) that reflects the phasing between the data. To reliably detect pathophysiological conditions during multimodal monitoring, some thresholds for the abovementioned indexes sc and mhpd have to be established that assign predefined significance levels to that thresholds. In this paper, we will present a method that determines the rate of false positives for fixed pairs of thresholds (lsc, lmhpd). We calculate these error rates as a function of the predefined thresholds for each individual out of a patient cohort of 52 patients in a retrospective way. Based on the deviation of the individual error rates, we subsequently determine a globally valid upper limit of the error rate by calculating the predictive interval. From this predictive interval, we deduce a globally valid significance level for appropriate pairs of thresholds that allows the application of sca to every future patient in a prospective, bedside fashion.
format Online
Article
Text
id pubmed-6109537
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-61095372018-08-29 A Patient-Independent Significance Test by Means of False-Positive Rates in Selected Correlation Analysis of Brain Multimodal Monitoring Data Faltermeier, Rupert Proescholdt, Martin A. Wolf, Stefan Bele, Sylvia Brawanski, Alexander Comput Math Methods Med Research Article Recently, we introduced a mathematical toolkit called selected correlation analysis (sca) that reliably detects negative and positive correlations between arterial blood pressure (ABP) and intracranial pressure (ICP) data, recorded during multimodal monitoring, in a time-resolved way. As has been shown with the aid of a mathematical model of cerebral perfusion, such correlations reflect impaired autoregulation and reduced intracranial compliance in patients with critical neurological diseases. Sca calculates a Fourier transform-based index called selected correlation (sc) that reflects the strength of correlation between the input data and simultaneously an index called mean Hilbert phase difference (mhpd) that reflects the phasing between the data. To reliably detect pathophysiological conditions during multimodal monitoring, some thresholds for the abovementioned indexes sc and mhpd have to be established that assign predefined significance levels to that thresholds. In this paper, we will present a method that determines the rate of false positives for fixed pairs of thresholds (lsc, lmhpd). We calculate these error rates as a function of the predefined thresholds for each individual out of a patient cohort of 52 patients in a retrospective way. Based on the deviation of the individual error rates, we subsequently determine a globally valid upper limit of the error rate by calculating the predictive interval. From this predictive interval, we deduce a globally valid significance level for appropriate pairs of thresholds that allows the application of sca to every future patient in a prospective, bedside fashion. Hindawi 2018-08-08 /pmc/articles/PMC6109537/ /pubmed/30159004 http://dx.doi.org/10.1155/2018/6821893 Text en Copyright © 2018 Rupert Faltermeier et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Faltermeier, Rupert
Proescholdt, Martin A.
Wolf, Stefan
Bele, Sylvia
Brawanski, Alexander
A Patient-Independent Significance Test by Means of False-Positive Rates in Selected Correlation Analysis of Brain Multimodal Monitoring Data
title A Patient-Independent Significance Test by Means of False-Positive Rates in Selected Correlation Analysis of Brain Multimodal Monitoring Data
title_full A Patient-Independent Significance Test by Means of False-Positive Rates in Selected Correlation Analysis of Brain Multimodal Monitoring Data
title_fullStr A Patient-Independent Significance Test by Means of False-Positive Rates in Selected Correlation Analysis of Brain Multimodal Monitoring Data
title_full_unstemmed A Patient-Independent Significance Test by Means of False-Positive Rates in Selected Correlation Analysis of Brain Multimodal Monitoring Data
title_short A Patient-Independent Significance Test by Means of False-Positive Rates in Selected Correlation Analysis of Brain Multimodal Monitoring Data
title_sort patient-independent significance test by means of false-positive rates in selected correlation analysis of brain multimodal monitoring data
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6109537/
https://www.ncbi.nlm.nih.gov/pubmed/30159004
http://dx.doi.org/10.1155/2018/6821893
work_keys_str_mv AT faltermeierrupert apatientindependentsignificancetestbymeansoffalsepositiveratesinselectedcorrelationanalysisofbrainmultimodalmonitoringdata
AT proescholdtmartina apatientindependentsignificancetestbymeansoffalsepositiveratesinselectedcorrelationanalysisofbrainmultimodalmonitoringdata
AT wolfstefan apatientindependentsignificancetestbymeansoffalsepositiveratesinselectedcorrelationanalysisofbrainmultimodalmonitoringdata
AT belesylvia apatientindependentsignificancetestbymeansoffalsepositiveratesinselectedcorrelationanalysisofbrainmultimodalmonitoringdata
AT brawanskialexander apatientindependentsignificancetestbymeansoffalsepositiveratesinselectedcorrelationanalysisofbrainmultimodalmonitoringdata
AT faltermeierrupert patientindependentsignificancetestbymeansoffalsepositiveratesinselectedcorrelationanalysisofbrainmultimodalmonitoringdata
AT proescholdtmartina patientindependentsignificancetestbymeansoffalsepositiveratesinselectedcorrelationanalysisofbrainmultimodalmonitoringdata
AT wolfstefan patientindependentsignificancetestbymeansoffalsepositiveratesinselectedcorrelationanalysisofbrainmultimodalmonitoringdata
AT belesylvia patientindependentsignificancetestbymeansoffalsepositiveratesinselectedcorrelationanalysisofbrainmultimodalmonitoringdata
AT brawanskialexander patientindependentsignificancetestbymeansoffalsepositiveratesinselectedcorrelationanalysisofbrainmultimodalmonitoringdata