Cargando…

Awake Rat Brain Functional Magnetic Resonance Imaging Using Standard Radio Frequency Coils and a 3D Printed Restraint Kit

Functional magnetic resonance imaging (fMRI) is a powerful noninvasive tool for studying spontaneous resting state functional connectivity (RSFC) in laboratory animals. Brain function can be significantly affected by generally used anesthetics, however, rendering the need for awake imaging. Only a f...

Descripción completa

Detalles Bibliográficos
Autores principales: Stenroos, Petteri, Paasonen, Jaakko, Salo, Raimo A., Jokivarsi, Kimmo, Shatillo, Artem, Tanila, Heikki, Gröhn, Olli
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6109636/
https://www.ncbi.nlm.nih.gov/pubmed/30177870
http://dx.doi.org/10.3389/fnins.2018.00548
_version_ 1783350357416476672
author Stenroos, Petteri
Paasonen, Jaakko
Salo, Raimo A.
Jokivarsi, Kimmo
Shatillo, Artem
Tanila, Heikki
Gröhn, Olli
author_facet Stenroos, Petteri
Paasonen, Jaakko
Salo, Raimo A.
Jokivarsi, Kimmo
Shatillo, Artem
Tanila, Heikki
Gröhn, Olli
author_sort Stenroos, Petteri
collection PubMed
description Functional magnetic resonance imaging (fMRI) is a powerful noninvasive tool for studying spontaneous resting state functional connectivity (RSFC) in laboratory animals. Brain function can be significantly affected by generally used anesthetics, however, rendering the need for awake imaging. Only a few different awake animal habituation protocols have been presented, and there is a critical need for practical and improved low-stress techniques. Here we demonstrate a novel restraint approach for awake rat RSFC studies. Our custom-made 3D printed restraint kit is compatible with a standard Bruker Biospin MRI rat bed, rat brain receiver coil, and volume transmitter coil. We also implemented a progressive habituation protocol aiming to minimize the stress experienced by the rats, and compared RSFC between awake, lightly sedated, and isoflurane-anesthetized rats. Our results demonstrated that the 3D printed restraint kit was suitable for RSFC studies of awake rats. During the short 4-day habituation period, the plasma corticosterone concentration, movement, and heart rate, which were measured as stress indicators, decreased significantly, indicating adaptation to the restraint protocol. Additionally, 10 days after the awake MRI session, rats exhibited no signs of depression or anxiety based on open-field and sucrose preference behavioral tests. The RSFC data revealed significant changes in the thalamo-cortical and cortico-cortical networks between the awake, lightly sedated, and anesthetized groups, emphasizing the need for awake imaging. The present work demonstrates the feasibility of our custom-made 3D printed restraint kit. Using this kit, we found that isoflurane markedly affected brain connectivity compared with that in awake rats, and that the effect was less pronounced, but still significant, when light isoflurane sedation was used instead.
format Online
Article
Text
id pubmed-6109636
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-61096362018-09-03 Awake Rat Brain Functional Magnetic Resonance Imaging Using Standard Radio Frequency Coils and a 3D Printed Restraint Kit Stenroos, Petteri Paasonen, Jaakko Salo, Raimo A. Jokivarsi, Kimmo Shatillo, Artem Tanila, Heikki Gröhn, Olli Front Neurosci Neuroscience Functional magnetic resonance imaging (fMRI) is a powerful noninvasive tool for studying spontaneous resting state functional connectivity (RSFC) in laboratory animals. Brain function can be significantly affected by generally used anesthetics, however, rendering the need for awake imaging. Only a few different awake animal habituation protocols have been presented, and there is a critical need for practical and improved low-stress techniques. Here we demonstrate a novel restraint approach for awake rat RSFC studies. Our custom-made 3D printed restraint kit is compatible with a standard Bruker Biospin MRI rat bed, rat brain receiver coil, and volume transmitter coil. We also implemented a progressive habituation protocol aiming to minimize the stress experienced by the rats, and compared RSFC between awake, lightly sedated, and isoflurane-anesthetized rats. Our results demonstrated that the 3D printed restraint kit was suitable for RSFC studies of awake rats. During the short 4-day habituation period, the plasma corticosterone concentration, movement, and heart rate, which were measured as stress indicators, decreased significantly, indicating adaptation to the restraint protocol. Additionally, 10 days after the awake MRI session, rats exhibited no signs of depression or anxiety based on open-field and sucrose preference behavioral tests. The RSFC data revealed significant changes in the thalamo-cortical and cortico-cortical networks between the awake, lightly sedated, and anesthetized groups, emphasizing the need for awake imaging. The present work demonstrates the feasibility of our custom-made 3D printed restraint kit. Using this kit, we found that isoflurane markedly affected brain connectivity compared with that in awake rats, and that the effect was less pronounced, but still significant, when light isoflurane sedation was used instead. Frontiers Media S.A. 2018-08-20 /pmc/articles/PMC6109636/ /pubmed/30177870 http://dx.doi.org/10.3389/fnins.2018.00548 Text en Copyright © 2018 Stenroos, Paasonen, Salo, Jokivarsi, Shatillo, Tanila and Gröhn. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Neuroscience
Stenroos, Petteri
Paasonen, Jaakko
Salo, Raimo A.
Jokivarsi, Kimmo
Shatillo, Artem
Tanila, Heikki
Gröhn, Olli
Awake Rat Brain Functional Magnetic Resonance Imaging Using Standard Radio Frequency Coils and a 3D Printed Restraint Kit
title Awake Rat Brain Functional Magnetic Resonance Imaging Using Standard Radio Frequency Coils and a 3D Printed Restraint Kit
title_full Awake Rat Brain Functional Magnetic Resonance Imaging Using Standard Radio Frequency Coils and a 3D Printed Restraint Kit
title_fullStr Awake Rat Brain Functional Magnetic Resonance Imaging Using Standard Radio Frequency Coils and a 3D Printed Restraint Kit
title_full_unstemmed Awake Rat Brain Functional Magnetic Resonance Imaging Using Standard Radio Frequency Coils and a 3D Printed Restraint Kit
title_short Awake Rat Brain Functional Magnetic Resonance Imaging Using Standard Radio Frequency Coils and a 3D Printed Restraint Kit
title_sort awake rat brain functional magnetic resonance imaging using standard radio frequency coils and a 3d printed restraint kit
topic Neuroscience
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6109636/
https://www.ncbi.nlm.nih.gov/pubmed/30177870
http://dx.doi.org/10.3389/fnins.2018.00548
work_keys_str_mv AT stenroospetteri awakeratbrainfunctionalmagneticresonanceimagingusingstandardradiofrequencycoilsanda3dprintedrestraintkit
AT paasonenjaakko awakeratbrainfunctionalmagneticresonanceimagingusingstandardradiofrequencycoilsanda3dprintedrestraintkit
AT saloraimoa awakeratbrainfunctionalmagneticresonanceimagingusingstandardradiofrequencycoilsanda3dprintedrestraintkit
AT jokivarsikimmo awakeratbrainfunctionalmagneticresonanceimagingusingstandardradiofrequencycoilsanda3dprintedrestraintkit
AT shatilloartem awakeratbrainfunctionalmagneticresonanceimagingusingstandardradiofrequencycoilsanda3dprintedrestraintkit
AT tanilaheikki awakeratbrainfunctionalmagneticresonanceimagingusingstandardradiofrequencycoilsanda3dprintedrestraintkit
AT grohnolli awakeratbrainfunctionalmagneticresonanceimagingusingstandardradiofrequencycoilsanda3dprintedrestraintkit